Jumper settings
Note: A/T = IDE
Jumper block location
Jumpers may be fitted to select the following options:
All other jumper setting patterns are reserved. Do not make other settings.
Shipping default settings
16 head logical architecture is enabled. Master is set to on (i.e. jumper on pins A-B and G-H) No other jumpers are fitted.
Description DHEA-34330 DHEA-36480 Physical layout Label capacity (MB) 4330 4680 Bytes per sector 512 512 Sectors/track 132-211 132-211 Number of heads 5 8 Number of disks 3 4 Logical layout1,2 Number of heads 16(15) 16(15) Number of sectors/track 63 63 Number of cylinders 8400 12592 (8960) (13424) Number of sectors 8467200 12692736 (8467200) (12685680) Total logical data bytes 4335206400 6498680832 (4335206400) (6495068160)
1Logical layout describes imaginary drive parameters which are used to access customer data. Logical layout to physical layout (i.e. actual head, sector) translation is done automatically. Default logical layout variables may be obtained by issuing an "Identify" command.
2Bracketed values show the alternate, jumper selectable, option.