home *** CD-ROM | disk | FTP | other *** search
-
-
-
- ***************************************
- * *
- * The 1986 COSMOS FILES *
- * PART III: Service Order Input *
- * Written by: *
- * *
- * SIR WILLIAM *
- * [KOTRT] *
- * *
- ***************************************
-
-
-
- The 1986 COSMOS FILE series consists of 6 parts, including the introduction,
- covering all major Service Orders, Work Orders, Reports, Facility and Circuit
- Alteration, COSMOS-N/PREMIS transactions and a complete list of all the
- facility prefixes. The 1986 file series is intended for the serious COSMOS
- hacker. (Not too serious)
-
- NOTE: The content of this material is proprietary and constitutes a trade
- secret. It is furnished pursuant to written agreements or instructions
- limiting the extent of its disclosure. Its further disclosure in any form
- without the permission of its owner, Western Electric Co. Inc., is prohibited.
- hi ho.
-
- DISCLAIMER: I take full responsibility for all deaths, physical injuries,
- emotional stress, and monetary damages as a result of this file.
- Please send all claims to KOTRT Enterprises, P.O. Box 1223-232,
- Wunderland, N. Ireland 928301
-
- ***************************************
- INTRO TO SERVICE ORDER INPUT
- ***************************************
-
- Under COSMOS software version 8.X there are new input procedures for SOE's.
- Although these are mostly in the area of error handling, they require a bit
- of discussion, seperate from the basic input.
-
- Error Handling
- --------------
- Service order transactions interact with the user more frequently in
- REV 8.X. Each time the transaction is ready for a new input, it will
- respond with and underscore "_" at the beginning of the new line. This
- indicates that the preceding line is correct.
- If an error does occur, the transaction will respond with an error
- message and prompt for correction. When an error occurs, you have
- 4 choices.
- 1. Re-enter the entire field correctly.
- 2. Enter line-feed to ignore, (checks rest of line)
- 3. Enter a ";" to disregard the present circuit.
- 4. Enter a "." the transaction will disregard all input, and exit.
-
- H-LINE inputs.
- --------------
- H-LINE input for the service order trio SOE/CSA/TSA is being rigidly
- defined in 8.0 according to three categories. These categorys contain
- fundamentally different types of order/facility information.
- Category 1: ORD, OT, DD, FDD,J OC, DT, SG, EO, LC
- Category 2: US, FEA, CCF, CAT, BTN, SS, AO, RZ, FR, GP/CG, CTX/CG/MG/NNX,
- LDN, RTI.
- Category 3: FW, RW
- Category 1 items are primary, once defined they cannot be changed
- by conflicting category 2, and 3 lines.
-
- SERVICE ORDER TRANSACTIONS
-
- Transaction Definition
- =========== ======================
- SOE Service Order Input
- TDZ Telephone Number Assignment lists
- LDZ Line Equipment Assignment list
- SOH Service Order withheld
- SOM Service Order Modification
- SOC Service Order Cancellation
- SOW Service Order Withdraw
- SCM Service Order Completion by MDF
- SCP Service Order Completion by PAO
- SCA Service Order Completion - Automatic
- SCF Service Order Completion for MDF automatic
- SCI Spare Cable pair inquiry
- CDD Change Due Date
- BAI Bridge Lifter Assignment Inquiry
- LAI Line Equipment Assignment Inquiry
- NAI Telephone Numbers Assignment Inquiry
- TAI Tie pair assignment Inquiry
- EDZ Facility Emergency Assignment list for backup
- MAP Manual Assignment Parameters
- MAL Manual Assignment list
- TSW Total Service Order Withdraw
-
- ***************************************
- TRANSACTIONS DEFINED
- ***************************************
-
- SOE - Service Order Establishment
- - Establishes a pending service order. The types of orders are; NC, CD,
- CH, F, T, SS, RS, R, RF. Reassociations are treated as change orders.
- - H-lines must contain ORD, DD, and OT. Optional facilities; FW, RW, FDD
- AO, FR, SG, and either DT or OC.
- - I and O lines may contain; US, FEA, CP, OE, TN, RZ, NNX, PL, TP, TK, BL, # SE, CON, MR, BTN, RC, RE, RT,STC, STN, STO, CCF, LCC, and RTI.
- - ESS orders requiring coordination by the recent change input center may # be flagged with an input of "RW C".
- Example of a NC [New Connect]
- WC% SOE
- H ORD NCXXXXXX/DD 01-01-86/OT NC/FDD 02-05-86/DT AM
- _I CP XXXXX-XXXXXX/OE ?/TN ?/US 2FR/FEA RNNL
- _.
-
- Example of a CD [Complete Disconnect]
- WC% SOE
- H ORD CDXXXXXX/DD 01-01-85/OT CD
- _O TN 534-1822
- _.
-
- Example of a CH [Change]
- WC% SOE
- H ORD CHXXXXX/OT CH/DD 01-01-86/TN 534-1822
- _O TN 534-1822/STN CO
- _I TN ?
- _.
- Example of SS [Suspension]
- WC% SOE
- H ORD SSXXXXX/OT SS/DD 01-01-86
- _O TN 534-1822/SS SB
- _.
-
- TDZ - Telephone Number Assignments List
- - List the indicated number of spare directory numbers for a NNX code, and
- directory number type.
- - Up to 25 directory numbers can be specified, using the prefix LC.
- Example
- WC% TDZ
- H NNX 534/TT G/LC 7 (LC can be up to 25)
- .
- Output example would look similar to this.
- **EMERGENCY FACILITY ASSIGNMENT LIST 01-01-86
- RESERVED LINE EQUIPMENT
- **NO SPARE LINE EQUIPMENT FOUND
- AVAILABLE DIRECTORY NUMBERS (7)
- 534-XXXX
- 534-XXXX, etc.
- **TRANSACTION COMPLETED
-
- SOW - Service Order Withdraw
- - Withdraws most recent version of a service order
- - Order number must refer to the latest version. The H-line circuit ID
- identifys the order. Valid circuit identifiers are; TN, XN, PL, CP, OE,
- and TK.
- Example
- WC% SOW
- H ORD NC-XXXXX/TN 534-1822
- .
-
- SCP - Service Order Completion by PAO
- - Record in the Service Order File the completion of an order by PAO
- - Standard SXX H line input.
- Example
- WC% H ord CDXXXXXX/TN 534-1822
- .
-
- SCA - Service Order Completion Automatic
- - Enters final completion on all service orders which have been or are
- not requried to be completed by the MDF, are not in a held, or jeopardy
- status, and are due prior to or on the current date.
- - Two due dates may be entered on the H-line; SCA will complete orders due # on or between the dates. Additional options are OT (order type), ORD,
- and SG.
- Example
- WC% SCA
- . :complete all orders on or before this due date
-
- Example2
- WC%SCA
- H DD 01-01-86/OT NC :Complete all NC (new connect) orders
- .
-
-
- CDD - Change Due Date
- - Change due date of a service or frame order
- - I think an example will suffice;
- WC% CDD
- H ORD CH-XXXXXX/TN 534-1822
- I DD 01-01-86
- .
- output example
- **ORD CH-XXXXX DUE DATE 01-01-86
-
-
- NAI - Telephone Number Assignment Inquiry
- - Provides from 1 to 25 spare telephone numbers compatable with the
- input specifications.
- - Input is an H-line with the TN type and NNX or RZ entries. The status of
- the TN supplied will be modified to reserved if ST is specified on the H-# line.
- Example
- WC% NAI
- H TT X/NNX 534/ST RS
- .
- this shows first available spare in prefix 534.
-
- MAP - Manual Assignment Parameter
- - Permits the PAO to establish the parameters that will constitute the PAO # Open-of-Day report.
- WC% MAP
- I NNX 534/ECS 1R/EQF TNNL/LC 50, etc. (for line equipment)
- I NNX 534/TT B/LC 10 (For Telephone numbers of type B, 10)
- etc.
-
- ==============================================================
- [C]OPYRIGHT 1986. KOTRT ENTERPRISES. WUNDERLAND, S. AFRICA
- ==============================================================
-
-
- Downloaded from P-80 Systems.....
-
-