home *** CD-ROM | disk | FTP | other *** search
/ Liren Large Software Subsidy 13 / 13.iso / p / p260 / 1.ddi / ROTOPT.HLP < prev    next >
Encoding:
Text File  |  1989-11-02  |  5.2 KB  |  94 lines

  1.  displacements entered in suboption [F.3] are erased. 
  2.  
  3. DISPLACEMENTS [F.3] 
  4.  
  5. Displacements are in Angstroms, the first to the right (y) and the second 
  6. upwards (z) from the center of the screen or paper.  When this suboption is 
  7. exercised, suboption [F.2] is turned off. 
  8.  
  9. The scale grid option [P.3] is useful for showing the actual scaled location 
  10. of the center of the structure and in estimating displacements. 
  11.  
  12. 
  13. ┘ ┌ █ ▄ ▌ ▐ ▀ α ß Γ π Σ σ µ τ Φ Θ Ω δ ∞ φ ε ∩ ≡ ± ≥ ≤ ⌠ ⌡ ÷ ≈ ° ∙ · √ ⁿ ² ■   ** Help file SERPOR.HLP - Serial port parameters. 
  14.  
  15. If your pen-plotter dot-matrix or laser graphics printer is on a serial port, 
  16. it is always necessary to initialize this port with the data-transmission 
  17. parameters (baud, parity, stop bits, data bits).  There is no alternative to 
  18. entering these values, which are often set by DIP switches on the printer.  
  19. Once the values are entered properly, the port will be initialized whenever 
  20. ATOMS is started. 
  21.  
  22. 
  23. ** Help file SYMMET.HLP - symmetry options. 
  24.  
  25. [B.3.2.1] SPACE-GROUP OPERATORS FROM SPACE-GROUP FILE. 
  26.  
  27. The best option for crystals is normally automatic reading of the symmetry 
  28. information from a special file (SPCGRP.DAT). In this case, it is necessary 
  29. to give only the space-group symbol or number.  For a similar input of point-
  30. group symmetry for molecules, use [B.3.2.2]. 
  31.  
  32. When entering a symbol, lower case should be converted to upper case, "bar" 
  33. axes are denoted by a capital B preceding the axis, and subscripts are 
  34. written as normal numbers, e.g. "PB421C".  Except when alternate orientations 
  35. for monoclinic space groups are chosen, the short form of the symbol is used: 
  36. for example for group number 63 use "CMCM", not "C2/M2/C21/M". 
  37.  
  38. To select an alternate orientation for monoclinic space groups, you must give 
  39. the LONG version of the symbol.  For example, the four orientations of space 
  40. group number 15 are B112/B, A112/A, C12/C1 and A12/A1.  If you use the short 
  41. form, you get the SECOND setting, which is the third of these. 
  42. [B.3.2.2] POINT-GROUP OPERATORS FROM SPACE-GROUP FILE.  
  43.  
  44. This is the normal choice for a molecule, provided the symmetry is 
  45. crystallographic and atomic coordinates conform to standard orientations.  It 
  46. is not applicable if the symmetry is trigonal or hexagonal and cartesian axes 
  47. are used; choose [B.3.2.3] in that case. You are shown the list of point 
  48. groups; use EITHER the International or Schoenflies symbol, which are 
  49. connected with equals signs. 
  50.  
  51. [B.3.2.3] CARTESIAN MATRICES FROM .SYM FILE. 
  52.  
  53. This option assumes that cartesian axes are in use.  It is the only option 
  54. applicable to non-crystallographic symmetry, and it can be used if desired in 
  55. any other case.  However, it is usually easier to use one of the other 
  56. options for crystallographic symmetry, with the possible exception of 
  57. trigonal and hexagonal molecules for which the coordinates are given on 
  58. cartesian axes. 
  59.  
  60. This option asks for the name of a file with suffix .SYM, containing the 
  61. cartesian symmetry matrices. Give the full name of the symmetry file, 
  62. including the .SYM suffix.  Some such files, notably those for pentagonal 
  63. (C5, D5, C5V, C5H, D5H and D5D) and icosahedral (I and IH) point groups, have 
  64. already been provided.  For other point groups, it will be necessary to run 
  65. the auxilliary program SYMGRP to generate the file before running ATOMS; see 
  66. section XVI. 
  67. [B.3.2.4] KEYBOARD ENTRY OF SYMMETRY OPERATORS. 
  68.  
  69. With this option, you enter the symmetry information in the form in which it 
  70. is given in the International Tables, and many reports on structures.  This 
  71. is sometimes useful for non-standard settings.  After specifying whether a 
  72. center is present and the Bravais lattice type, you enter the "Co-ordinates 
  73. of equivalent positions" for the general equipoint, as given in the Tables or 
  74. other source.  Basically, you just copy the entries, including commas and 
  75. semicolons, as many as you like on a line - break lines after operators, 
  76. which end with ** Help file PENCHG.HLP - Pen-change modes. 
  77.  
  78. If you have a multiple-pen plotter, you can elect to run in a single-pen mode, 
  79. and conversely if you have a single-pen plotter you can draw with multiple 
  80. colors, but you will have to change the pens manually. If you choose the 
  81. MANUAL pen-change mode (for a single-pen plotter), the plotter returns to the 
  82. zero position after drawing all lines of each color, and you are prompted on 
  83. the screen to change pens. Typing "return" after the pen change will continue 
  84. the plot.  Pen colors for crystal edges and structure axes are set in option 
  85. [K.11]; colors for atoms, bonds and polyhedra are set in the input for these 
  86. drawing elements. 
  87.  
  88. 
  89. [─Ωε.┼P┼h┼╞▓╞·╞=╟S╟ö╟σ╚▌╔╩9╩]╩k╩w╩▓╩╫╩≈╩    ╦╦U╦╦╦╙╦^╠≈╠╒o    ì    Ä      É    æ    Æ    ô    ö    ò    û    ù    ÿ    Ö    Ü    ¢    £    ¥    ₧    ƒ    á    í    ó    ú    ñ    Ñ    ª    º    ¿    ⌐    ¬    ½    ¼    ¡    «    »    ░    ▒    ▓    │    ┤    ╡    ╢    ╖    ╕    ╣    ║    ╗    ╝    ╜    ╛    ┐    └    ┴    ┬    ├    ─    ┼    ╞    ╟    ╚    ╔    ╩    ╦    ╠    ═    ╬      ╨    ╤    ╥    ╙    ╘    ╒    ╓    ╫    ╪    ┘    ┌    █    ▄    ▌    ▐    ▀    α    ß    Γ    π    Σ    σ    µ    τ    Φ    Θ    Ω    δ    ∞    φ    ε    ∩    ≡    ±    ≥    ≤    ⌠    ⌡    ÷    ≈    °    ∙    ·    √    ⁿ    ²    ■         
  90. ** Help file PENMOD.HLP - Pen plotter type and pen-change mode 
  91.  
  92. [M.2.4] PEN PLOTTER TYPE. 
  93.  
  94. If your plotter has only one pen, enter "single"; if it can change pe