home *** CD-ROM | disk | FTP | other *** search
- Newsgroups: comp.sys.hp
- Path: sparky!uunet!cs.utexas.edu!hellgate.utah.edu!csn!iem!larry
- From: larry@iem.com (Larry Fenske)
- Subject: Re: NEED: Jumper settings for HP97548 SCSI disk(s)
- Message-ID: <C19xu5.B2@iem.com>
- Date: Fri, 22 Jan 1993 21:18:00 GMT
- References: <1jmnbsINN2bg@cbl.umd.edu>
- Organization: IEM, Inc.
- X-Newsreader: Tin 1.1 PL4
- Lines: 50
-
- mike@starburst.umd.edu (Michael F. Santangelo) writes:
- : Just as subject implies, need jumper settings for the HP9754X SCSI disks
- : (specifically the 97548S, but most settings are same in this family).
- : This is also the C2203 ("Coyote") HP 660MB drives, the 9754X is the OEM
- : part number.
- :
- : Thanks!
- : --
- : -+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
- : Michael F. Santangelo + Internet: mike@cbl.umd.edu [work]
- : Computer & Network Systems Head + mike@kavishar.umd.edu [home]
- : Univ MD: CEES / CBL (Solomons Island) + BITNET: MIKE@UMUC [fwd to mike@cbl]
-
- OPTOIN SETTINGS
- 0 = Open, 1 = Short
-
- PIN 1: Reserved (Normally shorted)
- PIN 2: Drive initiation of SDTR message
- 0 = Inhibit initiation of SDTR message
- 1 = Enable initiation at Power On and RESET
- PIN 3: Parity
- 0 = Parity checking is disabled
- 1 = Parity checking is enabled
- PIN 4: Auto spin up
- 0 = Drive will not spin up until host sends start unit command
- 1 = Drive will automatically spin up on power on
- PINS 5-7: SCSI address
- +---------+---------+
- | PINS | |
- +---------+ DRIVE |
- | 5 6 7 | ADDRESS |
- +---------+---------+
- | 0 0 0 | 0 |
- | 0 0 1 | 1 |
- | 0 1 0 | 2 |
- | 0 1 1 | 3 |
- | 1 0 0 | 4 |
- | 1 0 1 | 5 |
- | 1 1 0 | 6 |
- | 1 1 1 | 7 |
- +---------+---------+
-
- (From "HP 9754XS/D SCSI Disk Drives OEM Product Manual", part number 5959-3987,
- Edition 1, Rev 1/11/89, Figure 3-5, page 3-10)
-
-
- ----
- Larry Fenske
- larry@iem.com
- IEM, Inc.
-