home *** CD-ROM | disk | FTP | other *** search
- Path: sparky!uunet!haven.umd.edu!darwin.sura.net!newsserver.jvnc.net!yale.edu!ira.uka.de!smurf.sub.org!nadia!amylnd!laosinh!gerrit
- From: gerrit@laosinh.stgt.sub.org (Gerrit Heitsch)
- Newsgroups: comp.dcom.modems
- Subject: Re: Giving up on Supra
- Message-ID: <F5Fls*Fg2@laosinh.stgt.sub.org>
- Date: Sun, 24 Jan 1993 17:22:49 MET
- References: <w7PDXB2w165w@infopls.chi.il.us> <C0wIr2.4L0@ddsw1.mcs.com> <XOmks*yf2@laosinh.stgt.sub.org>
- <1jmemoINN6ai@ni.umd.edu>
- Distribution: world
- Organization: Lao-Sinh project (private UUCP site)
- Lines: 44
-
- In article <1jmemoINN6ai@ni.umd.edu>, Louis A. Mamakos writes:
-
- > >IF the supra does not disconnect properly, you should blame
- > >Rockwell about it, not to implement it in the software they sell
- > >to manufacturers, that use the C1999-16 or C1993-11 as the CPU.
- > >The RC144DP is able to send a GSTN-cleardown to disconnect.
- > >Another possibility to disconnect would be to send a MNP LD or a
- > >V.42 DISC. Just a question of software not hardware!
- >
- > No, you should blame Supra if there is a problem with their modem.
- > You presumably bought a modem from Supra, and not from Rockwell.
-
- Yes, I bought my modem from Supra, but Supra does not write the ROM code
- (as far as I know) because Rockwell makes the instruction set of the
- C1999-16 or C1993-11 not available to the public, so all manufacturers,
- that use this CPU have to buy their code from Rockwell.
- (If someone has the instruction set and other data for the C1999-16
- or C1993-11 drop me a mail)
- You can ask for some special enhancements in the code as the
- code for the little display or S109 and S110, but all will be implemented
- by Rockwell and you will get the ready-to-burn code.
-
- The only thing I can blame supra for is not to push Rockwell hard
- enough to fix the bugs in their code for the RC144DP.
-
- > do you suppose Rockwell will do if you call them to get your Supra
- > modem repaired?
- I do not need to get my modem repaired, it works as it should except
- for very bad lines. But even with bad lines I can get working
- connections with ATS110=3S109=56.
-
- I have a data sheet for the RC144DP, you can program everything, but
- if you do not set the parameters for the internal DSP right, you will
- run into problems. I looks for me, that Rockwell has still some problems
- finding the right settings for bad lines for the RC144DP.
-
- Gerrit
-
- --
- Gerrit Heitsch Moenchweg 16 7038 Holzgerlingen Germany
- Logical adresses: UUCP: gerrit@laosinh.stgt.sub.org FIDO: (2:2407/106.9)
- If we will ever be visited by Aliens, it will be very hard to explain, why a
- lifeform, that is intelligent enough to build atomic weapons can be stupid
- enough to do it. (taken from GEO special about space, page 88-91)
-