  1. Newsgroups: sci.physics.fusion
  2. Path: sparky!uunet!cs.utexas.edu!sun-barr!ames!pacbell.com!UB.com!zorch!fusion
  3. From: ames!FNALD.FNAL.GOV!DROEGE
  4. Subject: Status #1 Cell 4A3
  5. Message-ID: <921221135641.20c01220@FNALD.FNAL.GOV>
  6. Sender: scott@zorch.SF-Bay.ORG (Scott Hazen Mueller)
  7. Reply-To: ames!FNALD.FNAL.GOV!DROEGE
  8. Organization: Sci.physics.fusion/Mail Gateway
  9. Date: Mon, 21 Dec 1992 21:02:46 GMT
  10. Lines: 36
  11.  
  12. This weekend I went through the cleaning procedure and loaded a cell.  I give
  13. myself D- on the job.  I can now just imagine what a lab looks like to do this
  14. work properly.  This is intended as a practice run for the new polished
  15. cathodes when I get them.  This cell was loaded with a cathode that was rolled
  16. and then "polished" by me.  The result is a surface that is worse that that
  17. which I started with.  But I must be running on Christmas day.  It is also a
  18. practice run for the Mark V/II calorimeter and for a lot of new code.  Who 
  19. knows what will happen when I tell it to ramp up to 60 C from the 4 C loading
  20. point.  
  21.  
  22. There is also a new gas system switch.  It turns out the old one leaked and 
  23. was the source of some of the mysterious gas measurements.  The gas system 
  24. looks really tight and held well within a cc for over a week, with all the 
  25. changes due to room temperature.  
  26.  
  27. The present plan is to charge with a ramp that increases the cell current by 
  28. about 20 ma per sq cm per 24 hours.  I know this is not a copy of anybody's 
  29. supposed successful result, but one has to use his head to try to guess what 
  30. should work.  So I am going for a very gentle loading of the lattice, and hope
  31. to get high loading by allowing plenty of time for things to move around.  
  32.  
  33. We put 200 ppm of Al into the electrolyte.  We are also running a "dummy" Pt
  34. cathode as the most negitive electrode in the cell.  This was turned on last
  35. night so it is likely cleaning out the 200 ppm Aluminum.  We will be able to 
  36. add more Al loaded electrolyte as does Mckubre as we run.  
  37.  
  38. This cell also has a heater on the catalyst.  Earlier the catalyst would stop
  39. working at these low temperatures.  
  40.  
  41. We will start the ramp up in current at 4 C tonight.
  42.  
  43. OK, Santa, I know they are scarce at the North Pole, but how about some joules
  44. for Christmas?  I will settle for Epiphany as the charge time will better match
  45. January 6.
  46.  
  47. Tom Droege
  48.