home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1992 #31 / NN_1992_31.iso / spool / sci / electron / 21744 < prev    next >
Encoding:
Internet Message Format  |  1992-12-30  |  2.0 KB

  1. Path: sparky!uunet!newsflash.concordia.ca!mizar.cc.umanitoba.ca!bison!sys6626!inqmind!dino
  2. From: dino@inqmind.bison.mb.ca (Tony stewart)
  3. Newsgroups: sci.electronics
  4. Subject: Re: RFI free dimmer switches...
  5. Message-ID: <DwoLwB2w165w@inqmind.bison.mb.ca>
  6. Date: Wed, 30 Dec 92 09:01:00 CST
  7. References: <13730@optilink.COM>
  8. Organization: The Inquiring Mind BBS  1 204 488-1607
  9. Lines: 37
  10.  
  11. walsh@optilink.COM (Mark Walsh) writes:
  12.  
  13. > From article <1992Dec26.063254.23524@murdoch.acc.Virginia.EDU>, by alexander@
  14. > > In article <72415@cup.portal.com> dbell@cup.portal.com (David J Bell) write
  15. > #>>But a light dimmer I have installed makes the lightbulb RING alot, and
  16. > #>>it's very annoying. The ringing gets worse when you dim the light. I'm
  17. > #>>wondering if a "RFI free" dimmer will reduce this ringing. Anyone know?
  18. > > You might look more in the direction of using a full wave
  19. > > rectifier and a filter cap. If you take the AC out of it
  20. > > completely...It CAN'T ring.
  21. > > You'll wind up with about 140 volts DC and that through a
  22. > > rheostat should work on a standard light bulb ok. (I think).
  23. > Yikes!  This will result in about 170VDC!  Not only is it a
  24. > bit more dangerous to deal with, but standard bulbs run this
  25. > way last a very short time.  But they'll be pretty efficient!
  26. > You must have a pretty large rheostat handy, or else you are
  27. > playing with fire.  There are far more efficient ways of
  28. > dealing with voltage conversion these days.  Why has nobody
  29. > mentioned switching power supplies, besides cost?
  30. > -- 
  31. > Mark Walsh (walsh@optilink) -- UUCP: uunet!optilink!walsh
  32. > AOL: BigCookie -- Amateur Radio: KM6XU@WX3K -- USCF: L10861
  33. > "What, me worry?" - William M. Gaines, 1922-1992
  34.  
  35. The voltage in DC will be just as safe as 120 VRMS x 1.414.
  36. If the switch is between the bridge and the triac then no surge will 
  37. occur to the bulb, just the triac!... I think this is the best & cheapest 
  38. solution
  39.  
  40. Tony Stewart
  41.  
  42. dino@inqmind.bison.mb.ca
  43. The Inquiring Mind BBS, Winnipeg, Manitoba  204 488-1607
  44.