- Newsgroups: comp.unix.aix
- Path: sparky!uunet!ornl!dsdx3.DSRD.ORNL.GOV!dx3
- From: dx3@dsrd.ornl.gov (C. H. Decker)
- Subject: FDDI help
- Message-ID: <dx3.10@dsrd.ornl.gov>
- Summary: FDDI on 560 won't run in dual ring with Cabletron concentrator
- Keywords: FDDI, Cabletron, Translated, Encapsulated
- Sender: usenet@ornl.gov (News poster)
- Organization: Martin Marietta Energy Systems
- Date: Mon, 23 Nov 1992 13:20:03 GMT
- Lines: 24
-
- I've been working on a problem off and on for the last four weeks with IBM
- trying to get FDDI up and running on our RS/6000 model 560. In short, we're
- trying to get FDDI up on the IBM dual attached with two Cabletron
- concentrators. The two concentrators work fine together. We have various
- machines on the other side of the network accessing both concentrators with
- no problems. When we put the IBM in the ring and try to communicate out or
- in, nothing. What's odd is that we get a link to the cards, but cannot see
- the card's address using the Cabletron Lanview software. We have tried
- changing out adapter cards, reconfiguring, bringing down every other adapter
- on the IBM, etc. The error log indicates that the card tries to receive
- something, encounters an error, then immediately goes into an error recovery
- mode, and shuts down. This pattern is consistent each time we configure.
- We suspect that there is a compatibility problem with the IBM and the
- Cabletron concentrators. Is there anyone out there who has IBM RS/6000
- equipment running dual and/or single attached with Cabletron concentrators?
-
- Thanks in advance!
-
- DX3@dsrd.ornl.gov
-
- MMES/DSRD
- C.H. Decker (615) 574-8014
- 1099 Commerce Park Dr.
- Oak Ridge, TN 37831-7620
-