home *** CD-ROM | disk | FTP | other *** search
/ Computerworld 1996 March / Computerworld_1996-03_cd.bin / hp / drivers / plotter / dj230250 / diagnost / whatsnew.txt < prev   
Text File  |  1995-12-01  |  2KB  |  60 lines

  1. ***************************************************
  2. ****  HP DESIGNJET 230/250C DIAGNOSTICS V2.01  ****
  3. ****             WHAT'S NEW ??                 ****
  4. ***************************************************
  5.  
  6. Bugs detected and tests affected:
  7.  
  8. (1) BAIL TEST:
  9.  
  10.     Bug ------>    In some  portable computers this test has a 
  11.                timeout error  even when  the plotter works 
  12.         correctly.
  13.  
  14.     Solution -> The  test  has  been  changed. Now you  can 
  15.         define  the  number  of  lifts the  plotter 
  16.         performs,  and   the   timeout   has   been 
  17.         increased.
  18.  
  19. (2) Y-AXIS TEST:
  20.  
  21.     Bug ------>    Incorrect  units (bug  does  not affect the 
  22.                  test)
  23.  
  24.     Solution -> The units  in  the difference  between real
  25.         and theorical speeds have been changed from
  26.         ips (inches per second) to eu/msec (encoder
  27.         units per milisecond).
  28.         This bug affects only the representation of
  29.         the units; the calculation are correct.
  30.  
  31. And that's all. Thanks  for any  further  feedback  you can 
  32. offer us.
  33.  
  34. ================================
  35. == UPGRADING THE DIAGNOSTICS  ==
  36. ================================
  37. To  upgrade  diagnostics  v 2.0  to v 2.01, just  copy  the 
  38. dj250c.exe and dj250c.ini  files to the  directory in which 
  39. the old version is installed.
  40.  
  41. The new files overwrite the old ones of the same name. Once
  42. this happens, the new version is installed.
  43.  
  44. ==============================
  45. == INSTALL THE DIAGNOSTICS. ==
  46. ==============================
  47. To  install the  diagnostics, read  the READ20.TXT file and
  48. follow the instructions.
  49.  
  50. Note: When you  install all the  diagnostics, you'll obtain
  51. ----  the last version directly.