  1. 411PT1.EXE Installation Instructions. 
  2. ===========================================================================
  3.  
  4. Section  1     Installing Patches on a Native NetWare Server.
  5. Section  2     Installing Patches on a NetWare of OS/2 Server.
  6. Section  3     Installing Patches on a NetWare SFT III Server.
  7. ___________________________________________________________________________
  8.  
  9.  
  10.      Novell has provided an installation script to be used with INSTALL.NLM 
  11.      "Product Options".  However it is still possible to manually copy the 
  12.      patches to the DOS partition.. C:\NWSERVER
  13.  
  14.      This script file can be run in several ways:
  15.      1- From local A: Drive at Server.
  16.      2- From local Drive at Client using Rconsole (F4).
  17.      3- From local SYS: volume (F3), by specifying the path including 
  18.        volume name..ie SYS:\411PT1.
  19.      4- From a different server on the network (F3) by specifying
  20.        full path including server name..ie Server_Name\SYS:\411PT1.
  21.  
  22.      NOTE: Fastest installation in order of performance is: 
  23.      option 3, option 4, option 2, option 1.
  24.  
  25.      PK411 has the following enhancements:
  26.  
  27.           - "PATCHES" console command has been enhanced.
  28.         - Patches are display as two types: 
  29.             - PK Patches, 
  30.                 Patches embedded in PK411.NLM.
  31.             - Discrete Patches,
  32.                 Patches which are not embedded in PK411.NLM.
  33.                    - Patches are displayed alphabetically.
  34.                    - Total number of Patches are at the bottom of the list.
  35.  
  36.     (SAMPLE SCREEN OF PATCHES COMMAND)
  37.     -----------------------------------------------------------------------------
  38.     |    PK Information:                                |
  39.     |         Desc: OS Patch Kit for NetWare v4.11 (970122)            |
  40.     |       Source: C:PK411.NLM                            |    
  41.     |      Version: v2.00e (01/22/97)                        |
  42.     |       Status: Some PK patches are NOT loaded/active            |
  43.     |    PK Patches:                                |
  44.     |      ACTMDLFX.NLM  v1.00  (09/20/96)  Status: ACTIVE            |
  45.     |      AUDCONFX.NLM  v1.00  (10/02/96)  Status: ACTIVE            |
  46.     |      AUDDELFX.NLM  v1.00  (10/02/96)  Status: ACTIVE            |
  47.     |      AUDOVFFX.NLM  v1.00  (10/02/96)  Status: ACTIVE            |
  48.     |      AUDRESFX.NLM  v1.00  (11/11/96)  Status: Inactive (not loaded)    |
  49.     |      DFSCCHFX.NLM  v1.00  (09/20/96)  Status: ACTIVE            |
  50.     |      DFSSETFX.NLM  v1.00  (09/20/96)  Status: ACTIVE            |
  51.     |      MACCONFX.NLM  v1.00  (10/02/96)  Status: ACTIVE            |
  52.     |      MIGPRGFX.NLM  v1.00  (09/20/96)  Status: ACTIVE            |
  53.     |      MSGFREFX.NLM  v1.00  (10/02/96)  Status: ACTIVE            |
  54.     |      RECALCFX.NLM  v1.00  (12/18/96)  Status: ACTIVE            |
  55.     |      RENENTFX.NLM  v1.00  (10/02/96)  Status: ACTIVE            |
  56.     |      STDIRHFX.NLM  v1.00  (09/20/96)  Status: ACTIVE            |
  57.     |    Discrete Patches:                            |
  58.     |      None                                    |
  59.     |    Hardware Loader ID:                            |
  60.     |      00000002                                |
  61.     |                                        |    
  62.     |                                        |    
  63.     -----------------------------------------------------------------------------
  64.  
  65.         (OTHER RELATED CONSOLE COMMANDS)                    
  66.         PMLOAD <patch_filename> (loads specified discrete patch)        
  67.         PMLOAD <dir_name>       (loads all patches in specified directory)    
  68.         PKLOAD <patch_name>     (loads specified patch from patch kit)        
  69.         PMUNLOAD /ALL           (unloads all patches)                
  70.         PMUNLOAD <patch_name>   (unloads specified patch)            
  71.    
  72.  
  73. ___________________________________________________________________________
  74.  
  75.  
  76.      Note for NetFRAME customers:  
  77.      Because of NetFRAMEs' unique architecture "Product Options" Install 
  78.      can not copy the patches to the boot drive.  Use the following 
  79.      RCONSOLE method to copy the patches to the boot drive.
  80.           1) Unzip the patch file to any directory.
  81.           2) Run RCONSOLE and connect to the NetFRAME server that you 
  82.           want to update.
  83.           3) Use ALT-F1 to bring up the RCONSOLE Menu.
  84.           4) Select the "Transfer Files To Server" option.
  85.           5) For the Source path, enter the complete DOS path, 
  86.                for example f:\patch\native\start and press enter.
  87.           6) For the Destination path, enter C:  and press enter.
  88.      RCONSOLE should then copy all the files located in the source directory.  
  89.      After that completes add the following lines to the STARTUP.NCF:
  90.           LOAD PK411
  91.      Remove all other load statements for PM410.NLM and patches.
  92.  
  93. ___________________________________________________________________________
  94.  
  95.      Note for AS400 customers:
  96.      Because of AS400's unique architecture "Product Options" Install 
  97.      can not copy the patches to the boot drive.  Use the following 
  98.      RCONSOLE method to copy the patches to the boot drive.
  99.           1) Unzip the patch file to any directory.
  100.           2) Run RCONSOLE and connect to the AS/400 server that you 
  101.           want to update.
  102.           3) Use ALT-F1 to bring up the RCONSOLE Menu.
  103.           4) Select the "Transfer Files To Server" option.
  104.           5) For the Source path, enter the complete DOS path, 
  105.                for example f:\patch\native\start and press enter.
  106.           6) For the Destination path, enter E:  and press enter.
  107.              NOTE: Drive E: is a READ-WRITE DRIVE, 
  108.                 Drive F: is a READ-ONLY DRIVE.
  109.      RCONSOLE should then copy all the files located in the source directory.  
  110.      After that completes add the following lines to the STARTUP.NCF:
  111.           LOAD PK411
  112.      Remove all other load statements for PM410.NLM and patches.
  113.      Do not remove the load statements for DIAG410.NLM, HIMOVE.NLM, and
  114.      QFPLDISK.DSK.
  115.  
  116. ___________________________________________________________________________
  117.  
  118.      Issue: 
  119.  
  120.      When selecting "PRODUCT OPTIONS" option in install, Screen to copy file appears 
  121.      instead of the "PRODUCT OPTIONS" screen. 
  122.  
  123.      (Copy Files Option, SCREEN)
  124.      ------------------------------------------------------------------------------------       
  125.      |                                                                |
  126.      |  NetWare files will be installed from path:                               |
  127.      |                                                               |
  128.      |    NW411:\PRODUCTS\NW411\INSTALL\IBM\DOS\XXX\ENGLISH\                        |
  129.      |                                                                |
  130.      |  If you are installing from CD-ROM or a network directory, verify           |
  131.      |  that the above path corresponds to the source directory where the           |
  132.      |  NetWare server installation files are located.  On CD-ROM, this            |
  133.      |  will be path                                     |
  134.      |    <drive_or_vo_name>:\PRODUCTS\NW411\INSTALL\IBM\<DOS_OR_OS2>\XXX\<language_dir>. |
  135.      |                                                                |
  136.      |    Press <F3> to specify a different path;                            |
  137.      |    Press <Enter> to continue.                                         |
  138.      |                                                                |
  139.      ------------------------------------------------------------------------------------
  140.  
  141.      Solution:
  142.  
  143.      Copy the following files from the NetWare CD to C:\NWSERVER: 
  144.  
  145.     ADDLANG  IPS      400   8-12-96   1:20p
  146.     CHGLANG  IPS     2051   8-26-96   3:15p
  147.     COMDEF   ILS     4928   8-25-96   6:30p
  148.     COMDRIVR ICS      617   3-16-96  12:31p
  149.     COMMAIN  ICS    10657   8-27-96  11:05a
  150.     COMMAIN  ILS     2741   8-25-96   6:44p
  151.     COMOTHR  ILS    14328   8-24-96  11:29p
  152.     CPYCLINT IPS     2273   8-26-96  11:27a
  153.     HWDEF    ILS      485   8-12-96   1:20p
  154.     HWDRIVR  ICS     1797   8-26-96  12:50p
  155.     HWMAIN   ICS      534   3-16-96  12:31p
  156.     HWMAIN   ILS     1243   8-26-96   1:25p
  157.     HWOTHR   ILS      522   8-12-96   1:20p
  158.     INSTCMD1 IZX       12   2-16-94   3:07p
  159.     INSTNCF3 IZX       16   3-17-95   3:10p
  160.     INSTNCF4 IZX       31   5-03-96   9:10a
  161.     MAKEDISK IPS     4237   8-26-96   1:13p
  162.     NETMAIN  ILS     9852   9-07-96   6:21p
  163.  
  164.      Some of these files are Language specific..
  165.  
  166.      Generally this is a result of manually installing the server rather than
  167.      installing though INSTALL.BAT.
  168.  
  169. ___________________________________________________________________________
  170.  
  171.      Issue:
  172.  
  173.      When the Patch kit is installed, SERVER.EXE will be updated with the 
  174.      current version of LOADER. Some customers have indicated that the 
  175.      modified version of SERVER.EXE becomes corrupt with the following 
  176.      message:
  177.      
  178.      LOADER-4.11-19: Error reading load file C:\NWSERVER\SERVER.EXE.
  179.  
  180.      This corruption has been linked to the DIE_HARD VIRUS.
  181.  
  182.      Solution:
  183.  
  184.      1-Scan the DOS Boot drive of the file server, as well as any locations
  185.      where the patch kit may have been copied to.  Novell has ensured that
  186.      the virus has not been encapsulated in the compressed downloadable 
  187.      patch kit.  
  188.  
  189.      2-Rename SERVER.OLD or MSERVER.OLD to SERVER.EXE or MSERVER.EXE.
  190.      
  191.      3-RUN LSWAP.EXE 
  192.  
  193.      USAGE: LSWAP [LoaderFilePath [ServerFilePath]]
  194.  
  195.      Default LoaderFilePath = C:\NWSERVER\LOADER.EXE
  196.      Default ServerFilePath = C:\NWSERVER\SERVER.EXE
  197.      
  198.  
  199.      4-Run the newly modified SERVER.EXE or MSERVER.EXE if running SFTIII.
  200.  
  201. ===========================================================================
  202. Section  1     Installing Patches on a Native NetWare Server.
  203. ___________________________________________________________________________
  204.  
  205. IF INSTALLING ON A NATIVE NETWARE SERVER:
  206.  
  207.      To Copy files :
  208.           Explode the patch kit to a diskette 
  209.         (or see other install options at the top of this file).
  210.           Place diskette in "A:" drive at the Server.
  211.           Load "INSTALL.NLM",  
  212.           Select "PRODUCT OPTIONS"
  213.           Select "INSTALL A PRODUCT NOT LISTED"
  214.           Select "ENTER" (Copy from A:\)
  215.  
  216.           NOTE:  PI_ICMD.NLM will load and copy files from the A: drive using 
  217.          the *.IPS script.
  218.  
  219.           The following event will occur:
  220.                Patches will be copied
  221.                PK411 will be loaded
  222.                LSWAP will update SERVER.EXE.
  223.                A backup of The STARTUP.NCF file will made and then the
  224.                STARTUP.NCF will be updated..
  225.            A Record will be added to the btrieve Products.dat file.
  226.  
  227.      Some modules may NOT have loaded during this installation.  These modules
  228.      may be dependent on the version of PM410.NLM and also the version of LOADER.EXE. 
  229.  
  230.      To Complete the installation of this update, the server must be re-booted.
  231.  
  232. ===========================================================================
  233. Section  2     Installing Patches on a NetWare for OS/2 Server.
  234. ___________________________________________________________________________
  235.  
  236. IF INSTALLING ON A NATIVE NETWARE  FOR OS/2 SERVER:
  237.      To Copy files :
  238.           Explode the patch kit to a diskette.
  239.           Place diskette in "A:" drive at the Server.
  240.           Load "INSTALL.NLM",  
  241.           Select "PRODUCT OPTIONS"
  242.           Select "INSTALL A PRODUCT NOT LISTED"
  243.           Select "ENTER" (Copy from A:\)
  244.  
  245.           NOTE:  PI_ICMD.NLM will load and copy files from the A: drive using 
  246.          the *.IPS script.
  247.  
  248.           The following event will occur:
  249.                Patches will be copied
  250.                PK411 will be loaded
  251.                A backup of The STARTUP.NCF file will made and then the
  252.                STARTUP.NCF will be updated..
  253.            
  254.        NOTE: A Record will be NOT added to the btrieve Products.dat file.
  255.  
  256.      Some modules may NOT have loaded during this installation.  These modules
  257.      may be dependent on the version of PM410.NLM and also the version of LOADER.EXE. 
  258.  
  259.      To Complete the installation of this update, the server must be re-booted.
  260.  
  261.  
  262. ===========================================================================
  263. Section  3     Installing Patches on a NetWare SFT III Server.
  264. ___________________________________________________________________________
  265.  
  266. IF INSTALLING ON A NETWARE SFTIII SERVER:
  267.      To Copy files :
  268.           Explode the patch kit to SYS:\411PT1
  269.           Load "INSTALL.NLM",  
  270.           Select "PRODUCT OPTIONS"
  271.           Select "INSTALL A PRODUCT NOT LISTED"
  272.           Select "F3" (TO specify a different path)
  273.           ENTER: "SYS:\411PT1"
  274.           PRESS  "ENTER"
  275.  
  276.           NOTE:  PI_ICMD.NLM will load and copy files from the SYS:\411PT1 
  277.       drive using the *.IPS script.
  278.  
  279.           The following event will occur:
  280.                Patches will be copied
  281.                PK411 will be loaded
  282.                A backup of The IOSTART.NCF and MSSTART.NCF files will be made 
  283.                and then the IOSTART.NCF and MSSTART.NCF will be updated..
  284.                LSWAP will update MSERVER.EXE.
  285.                A Record will be added to the btrieve Products.dat file.
  286.  
  287.      
  288.      To Complete the installation of this update, the server must be re-booted.
  289.  
  290. ___________________________________________________________________________
  291.           