- Number: A1TH090590U581
- Subject: Errors Using 286 v2.15a Bridge Connected to v2.15c Server
- Date: January 28, 1991
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-
- PROBLEM: A client was using a Cubix board in a protected mode
- nondedicated bridge with a NE2000. The bridge was working
- under NetWare 286 v2.15a. He upgraded the file server to
- v2.15c (bridge was left at v2.15a). The bridge would load
- fine, but when he tried to login he would get an error
- reading from file server. He had the latest drivers.
-
- SOLUTION: We regenerated the bridge with the v2.15c software and
- everything worked.
-
- (X) This information was verified verbally
-
-