home *** CD-ROM | disk | FTP | other *** search
Text File | 1991-07-10 | 340.1 KB | 8,566 lines |
- [ PROTOCOLS:MSTD-1777-TESTS2.DOC ] [ 4/88 ]
-
-
- - Can the IUT interpret a bad option and a good option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- whose option field contains a security option with an invalid
- security level and a stream ID option. The IUT may discard the
- datagram and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2040 "
- or "ICMP PARAMETER PROBLEM id=02040".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2040 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2041 bad security option plus good stream identification
- option
-
- - Can the IUT interpret a bad option and a good option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- whose option field contains a security option with an invalid
- option length and a stream ID option. The IUT may discard the
- datagram and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2041 "
- or "ICMP PARAMETER PROBLEM id=02041".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2041 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2042 ordinary datagram after bad stream ID option tests
-
- - Can the IUT send a datagram after processing nastygrams?
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 2042 " in its 13-byte
- data field.
-
- Success: A reply datagram containing "ident = 2042 ".
-
- Failure: Any response other than the display of the
- requested reply datagram. The actual failure probably
- occurred during tests 2028-2041.
-
- Test 2043 truncated record route option
-
- - Can the IUT interpret a truncated record route option?
-
- - Action: Send a datagram to the IP Implementation Under
- Test with an 8-byte option field. The first two bytes are no
- operation options followed by a truncated record route
- option. The IUT may discard the datagram and send an
- optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- -The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2043"
- or "ICMP PARAMETER PROBLEM id=02043".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2043 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2044 record route option length bumped by 1
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an 8-byte option field. The first byte is a no operation
- option. This is followed by a record route option whose option
- length has been bumped by 1. The IUT may discard the datagram
- and send an optional ICMP Parameter Problem message.
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2044 "
- or "ICMP PARAMETER PROBLEM id=02044".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2044 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2045 record route option one byte too long
-
- - Can the IUT interpret a defective option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an 8-byte option field. This consists of a record route
- option that is one byte too long. The IUT may discard the
- datagram and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2045 "'
- or "ICMP PARAMETER PROBLEM id=02045".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2045 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2046 record route option one byte too short
-
- - Can the IUT interpret a defective option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an 8-byte option field. This consists of a record route
- option that is one byte too short followed by an an end of
- option list option and one byte of padding. The IUT may
- discard the datagram and send an optional ICMP Parameter
- Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2046 "
- or "ICMP PARAMETER PROBLEM id=02046".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2046 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2047 record route option length of 0
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an 8-byte option field. This contains a record route
- option with an option length of 0. The IUT may discard the
- datagram and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2047 "
- or "ICMP PARAMETER PROBLEM id=02047".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2047 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2048 record route option length of 377 octal
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a record route option with
- an option length of 377 octal. The IUT may discard the
- datagram and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2048 "
- or "ICMP PARAMETER PROBLEM id=02048".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2048 ", or nothing.
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2049 record route option length of 353 octal
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a record route option with
- an option length of 353 octal. The IUT may discard the
- datagram and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2049
- or "ICMP PARAMETER PROBLEM id=02049".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2049 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2050 record route option length of 177 octal
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a record route option with
- an option length of 177 octal. The IUT may discard the
- datagram and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2050"
- or "ICMP PARAMETER PROBLEM id=02050".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2050 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2051 record route option length of 200 octal
-
- - Can the IUT interpret a defective option length?
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a record route option with
- an option length of 200 octal. The IUT may discard the
- datagram and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2051 "'
- or "ICMP PARAMETER PROBLEM id=02051".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2051 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2052 record route option length of 207 octal
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a record route option with
- an option length of 207 octal (sign bit set). The IUT may
- discard the datagram and send an optional ICMP Parameter
- Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2052 "'
- or "ICMP PARAMETER PROBLEM id=02052".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2052 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2053 record route option pointer bumped by 1
-
- - Can the IUT interpret a defective option pointer?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a record route option with
- an option pointer that is one more than it should be. The IUT
- may discard the datagram and send an optional ICMP Parameter
- Problem message.
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2053 "
- or "ICMP PARAMETER PROBLEM id=02053".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2053 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2054 record route option pointer one short
-
- - Can the IUT interpret a defective option pointer?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a record route option with
- an option pointer that is one less than it should be. The IUT
- may discard the datagram and send an optional ICMP Parameter
- Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2054 "
- or "ICMP PARAMETER PROBLEM id=02054".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2054 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2055 record route option pointer of 300 octal
-
- - Can the IUT interpret a defective option pointer?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a record route option with
- an option pointer of 300 octal. The IUT may discard the
- datagram and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2055 "'
- or "ICMP PARAMETER PROBLEM id=02055".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2055 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than sn
- ICMP Parameter Problem message or reply datagram.
-
- Test 2056 record route option pointer of 174 octal .
-
- - Can the IUT interpret a defective option pointer?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a record route option with
- an option pointer of 174 octal. The IUT may discard the
- datagram and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2056 "
- or "ICMP PARAMETER PROBLEM id=02056".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2056 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2057 record route option with bad option length and option
- pointer
-
- - Can the IUT interpret a defective record route option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an 8-byte option field. This contains a record route
- option whose option length and option pointer have been bumped
- by 12. The IUT may discard the datagram and send an optional
- ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2057 "
- or "ICMP PARAMETER PROBLEM id=02057".
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2057 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2058 record route option with bad option pointer
-
- - Can the IUT interpret a defective option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a record route option with
- an option pointer that just exceeds its maximum legal value.
- The IUT may discard the datagram and send an optional ICMP
- Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2058 "
- or "ICMP PARAMETER PROBLEM id=02058".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2058 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2059 record route option with bad option pointer
-
- - Can the IUT interpret a defective option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with-an option field. This contains a two address field record
- route option with an option pointer that just exceeds its
- maximum legal value. The IUT may discard the datagram and send
- an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2059 "
- or "ICMP PARAMETER PROBLEM id=02059".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2059 ", or nothing.
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2060 record route option duplicated
-
- - Can the IUT interpret a duplicated record route option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- whose option field contains two identical record route
- options. The IUT may discard the datagram and send an optional
- ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2060 "
- or "ICMP PARAMETER PROBLEM id=02060".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2060 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2061 two record route options
-
- - Can the IUT interpret two options of the same type?
-
- - Action: Send a datagram to the IP Implementation Under Test
- whose option field contains two different record route
- options. The IUT may discard the datagram and send an optional
- ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2061 "
- or "ICMP PARAMETER PROBLEM id=02061".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2061 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2062 ordinary datagram after bad record route option tests
- - Can the IUT send a datagram after processing nastygrams?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 2062 " in its 13-byte
- data field.
-
- Success: A reply datagram containing "ident = 2062 ".
-
- Failure: Any response other than the display of the
- requested reply datagram. The actual failure probably
- occurred during tests 2043-2061.
-
- Test 2063 truncated timestamp option
-
- - Can the IUT interpret a truncated timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an 8-byte option field. The first byte is a no operation
- option followed by a truncated timestamp option. The IUT may
- discard the datagram and send an optional ICMP Parameter
- Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2063 "
- or "ICMP PARAMETER PROBLEM id=02063".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2063 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2064 timestamp option length bumped by 1
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an 8-byte option field consisting of a timestamp option
- whose option length has been bumped by 1. The IUT may discard
- the datagram and send an optional ICMP Parameter Problem
- message.
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2064 "
- or "ICMP PARAMETER PROBLEM id=02064".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2064 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2065 timestamp option one byte too long
-
- - Can the IUT interpret a defective option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a 12-byte option field. This contains a timestamp option
- that is one byte too long. The IUT may discard the datagram
- and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2065 "
- or "ICMP PARAMETER PROBLEM id=02065".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2065 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP-Parameter Problem message or reply datagram.
-
- Test 2066 timestamp option one byte too short
-
- - Can the IUT interpret a defective option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an 8-byte option field. This consists of a timestamp
- option that is one byte too short followed by an an end of
- option list option. The IUT may discard the datagram and send
- an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2066 "
- or "ICMP PARAMETER PROBLEM id=02066".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2066 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2067 timestamp option length of 0
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an 8-byte option field. This contains a timestamp option
- with an option length of 0. The IUT may discard the datagram
- and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2067 "
- or "ICMP PARAMETER PROBLEM id=02067".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2067 ", or nothing.
-
- Failure: An IP Tester display of a datagram other thsn an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2068 timestamp option length of 374 octal
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a timestamp option with an
- option length of 374 octal. The IUT may discard the datagram
- and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2068 "
- or "ICMP PARAMETER PROBLEM id=02068".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2068 ", or nothing.
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2069 timestamp option length of 354 octal
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a timestamp option with an
- option length of 354 octal. The IUT may discard the datagram
- and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2069 "
- or "ICMP PARAMETER PROBLEM id=02069".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2069 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2070 timestamp option length of 174 octal
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a timestamp option with an
- option length of 174 octal. The IUT may discard the datagram
- and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2070 "
- or "ICMP PARAMETER PROBLEM id=02070".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2070 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2071 timestamp option length of 200 octal
-
- - Can the IUT interpret a defective option length?
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a timestamp option with an
- option length of 200 octal. The IUT may discard the datagram
- and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2071 "
- or "ICMP PARAMETER PROBLEM id=02071".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2071 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2072 timestamp option length of 210 octal
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a timestamp option with an
- option length of 210 octal (sign bit set). The IUT may
- discard the datagram and send an optional ICMP Parameter
- Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2072 "'
- or "ICMP PARAMETER PROBLEM id=02072".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2072 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2073 timestamp option pointer bumped by 1
-
- - Can the IUT interpret a defective option pointer?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a timestamp option with an
- option pointer that is one more than it should be. The IUT may
- discard the datagram and send an optional ICMP Parameter
- Problem message.
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2073 "
- or "ICMP PARAMETER PROBLEM id=02073".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2073 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2074 timestamp option pointer one short
-
- - Can the IUT interpret a defective option pointer?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a timestamp option with an
- option pointer that is one less than it should be. The IUT may
- discard the datagram and send an optional ICMP Parameter
- Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2074 "
- or "ICMP PARAMETER PROBLEM id=02074".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2074 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2075 timestamp option pointer of 301 octal
-
- - Can the IUT interpret a defective option pointer?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a timestamp option with an
- option pointer of 301 octal. The IUT may discard the datagram
- and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2075 "
- or "ICMP PARAMETER PROBLEM id=02075".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2075 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2076 timestamp option pointer of 175 octal
-
- - Can the IUT interpret a defective option pointer?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a timestamp option with an
- option pointer of 175 octal. The IUT may discard the datagram
- and send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2076 "
- or "ICMP PARAMETER PROBLEM id=02076".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident= 2076 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2077 timestamp option with bad option length and option
- pointer
-
- - Can the IUT interpret a defective timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an 8-byte option field. This contains a timestamp option
- whose option length and option pointer have been bumped by 12.
- The IUT may discard the datagram and send an optional ICMP
- Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2077 "
- or "ICMP PARAMETER PROBLEM id=02077".
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2077 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2078 timestamp option with bad option pointer
-
- - Can the IUT interpret a defective option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a timestamp option with an
- option pointer that just exceeds its maximum legal value. The
- IUT may discard the datagram and send an optional ICMP
- Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2078 "
- or "ICMP PARAMETER PROBLEM id=02078".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2078 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2079 timestamp option with bad option pointer
-
- - Can the IUT interpret a defective option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with -an option field. This contains a two address field
- timestamp option with an option pointer that just exceeds its
- maximum legal value. The IUT may discard the datagram and send
- an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2079 "
- or "ICMP PARAMETER PROBLEM id=02079".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2079 ", or nothing.
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2080 timestamp option duplicated
-
- - Can the IUT interpret a duplicated timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- whose option field contains two identical timestamp options.
- The IUT may discard the datagram and send an optional ICMP
- Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2080"
- or "ICMP PARAMETER PROBLEM id=02080".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2080 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2081 two timestamp options
-
- - Can the IUT interpret two options of the same type?
-
- - Action: Send a datagram to the IP Implementation Under Test
- whose option field contains two different timestamp options.
- The IUT may discard the datagram and send an optional ICMP
- Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2081 "
- or "ICMP PARAMETER PROBLEM id=02081".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2081 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2082 timestamp option with bad timestamp option format
-
- - Can the IUT interpret a defective option?
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a timestamp option with an
- illegal format value. The IUT may discard the datagram amd
- send an optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2082 "
- or "ICMP PARAMETER PROBLEM id=02082".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2082 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2083 truncated timestamp option
-
- - Can the IUT interpret a truncated timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a 12-byte option field. The first byte is a no operation
- option followed by a truncated timestamp and address timestamp
- option. The IUT may discard the datagram and send an optional
- ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2083 "
- or "ICMP PARAMETER PROBLEM id=02083".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2083 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2084 timestamp option length bumped by 1
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under
- Test with a 12-byte option field consisting of a prespecified
- timestamp option whose option length has been bumped by 1.
- The IUT may discard the datagram and send an optional ICMP
- Parameter Problem message.
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2084 "
- or "ICMP PARAMETER PROBLEM id=02084".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2084 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2085 timestamp option one byte too long
-
- - Can the IUT interpret a defective option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a 16-byte option field. This contains a timestamp and
- address timestamp option that is one byte too long. The IUT
- may discard the datagram and send an optional ICMP Parameter
- Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2085 "
- or "ICMP PARAMETER PROBLEM id=02085".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2085 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2086 timestamp option four bytes too short
-
- - Can the IUT interpret a defective option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a 16-byte option field. This consists of a prespecified
- timestamp option that is 4 bytes too short. The IUT may
- discard the datagram and send an optional ICMP Parameter
- Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2086 "
- or "ICMP PARAMETER PROBLEM id=02086".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2086 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2087 timestamp option four bytes too short
-
- - Can the IUT interpret a defective option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a 16-byte option field. This consists of a timestamp and
- address timestamp option that is 4 bytes too short. The IUT
- may discard the datagram and send an optional ICMP Parameter
- Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2087 "
- or "ICMP PARAMETER PROBLEM id=02087".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2087 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2088 timestamp option length of 374 octal
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a prespecified timestamp
- option with an option length of 374 octal. The IUT may discard
- the datagram and send an optional ICMP Parameter Problem
- message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2088 "
- or "ICMP PARAMETER PROBLEM id=02088".
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2088 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2089 timestamp option length of 354 octal
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a timestamp and address
- timestamp option with an option length of 354 octal. The IUT
- may discard the datagram and send an optional ICMP Parameter
- Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2089 "
- or "ICMP PARAMETER PROBLEM id=02089".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ide-nt = 2089 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2090 timestamp option length of 174 octal
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a prespecified timestamp.
- option with an option length of 174 octal. The IUT may discard
- the datagram and send an optional ICMP Parameter Problem
- message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2090 "
- or "ICMP PARAMETER PROBLEM id=02090".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2090 ", or nothing.
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2091 timestamp option length of 200 octal
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a timestamp and address
- timestamp option with an option length of 200 octal. The IUT
- may discard the datagram and send an optional ICMP Parameter
- Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2091 "
- or "ICMP PARAMETER PROBLEM id=02091".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2091 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2092 timestamp option length of 214 octal
-
- - Can the IUT interpret a defective option length?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a prespecified timestamp
- option with an option length of 214 octal (sign bit set). The
- IUT may discard the datagram and send an optional ICMP
- Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2092 "
- or "ICMP PARAMETER PROBLEM id=02092".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2092 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2093 timestamp option pointer bumped by 4
- - Can the IUT interpret a defective option pointer?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a timestamp and address
- timestamp option with an option pointer that is four more than
- it should be. The IUT may discard the datagram and send an
- optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagrsm required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2093"
- or "ICMP PARAMETER PROBLEM id=02093".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2093 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2094 timestamp option pointer four short
-
- - Can the IUT interpret a defective option pointer?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a prespecified timestamp
- option with an option pointer that is four less than it should
- be. The IUT may discard the datagram and send an optional ICMP
- Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2094"
- or "ICMP PARAMETER PROBLEM id=02094".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2094 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2095 timestamp option pointer of 305 octal
-
- - Can the IUT interpret a defective option pointer?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a timestamp and address
- timestamp option with an option pointer of 305 octal. The IUT
- may discard the datagram and send an optional ICMP Parameter
- Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2095 "
- or "ICMP PARAMETER PROBLEM id=02095".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2095 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2096 timestamp option pointer of 175 octal
-
- - Can the IUT interpret a defective option pointer?
-
- - Action: Send a datagram to the IP Implementstion Under Test
- with an option field. This contains a prespecified timestamp
- option with an option pointer of 175 octal. The IUT may
- discard the datagram and send an optional ICMP Parameter
- Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2096 "
- or "ICMP PARAMETER PROBLEM id=02096".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2096 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2097 timestamp option with bad option length and option
- pointer
-
- - Can the IUT interpret a defective timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a 12-byte option field. This contains a timestamp and
- address timestamp option whose option length and option
- pointer have been bumped by 16. The IUT may discard the
- datagram and send an optional ICMP Parameter Problem message.
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2097"
- or "ICMP PARAMETER PROBLEM id=02097".
-
- Success: An ICMP Parameter Problem message, a reply datagram
- containing "ident = 2097 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2098 timestamp option with bad option pointer
-
- - Can the IUT interpret a defective option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with an option field. This contains a prespecified timestamp
- option with an option pointer that just exceeds its maximum
- legal value. The IUT may discard the datagram and send an
- optional ICMP Parameter Problem message.
-
- The IUT may pass the datagram to its Remote Driver instead.
- The IUT's Remote Driver should request the IUT to send the
- reply datagram required by the IP Remote Driver Specification
- to the IP Tester.
-
- - Verification: If there is a datagram displayed by the IP
- Tester, its display ought to contain either "ident = 2098"
- or "ICMP PARAMETER PROBLEM id=02098".
-
- Success: An ICMP Parameter Problem message, a reply datagrsm
- containing "ident = 2098 ", or nothing.
-
- Failure: An IP Tester display of a datagram other than an
- ICMP Parameter Problem message or reply datagram.
-
- Test 2099 ordinary datagram after bad timestamp option tests
-
- - Can the IUT send a datagram after processing nastygrams?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 2099 " in its 13-byte
- data field.
- Success: A reply datagram containing "ident =2099 ".
-
- Failure: Any response other than the display of the
- requested reply datagram. The actual failure probably
- occurred during tests 2063-2098.
- Scenario File OptBdTopTest: "Top-down Bad Option Field" datagrams
-
- 4000 security option without copy bit set
-
- 4001 loose source and record route option without copy bit set
-
- 4002 timestamp option without bit 6 set
-
- 4003 stream ID option without copy bit set
-
- 4004 strict source and record route option without copy bit
- set
-
- 4005 "option" with option type of 77 octal
-
- 4006 "option" with option type of 101 octal
-
- 4007 "option" with option type of 177 octal
-
- 4008 record route option with copy bit set
-
- 4009 prespecified timestamp option with copy bit set
-
- 4010 end of options list option with copy bit set
-
- 4011 no operation option with copy bit set
-
- 4012 ordinary datagram after bad option type tests
-
- 4013 truncated security option
-
- 4014 security option length bumped by 1
-
- 4015 security option one byte too long
-
- 4016 security option one byte too short
-
- 4017 security option length of 0
-
- 4018 security option length of 377 octal
-
- 4019 security option length of 353 octal
-
- 4020 security option length of 177 octal
-
- 4021 security option length of 200 octal
-
- 4022 security option length of 213 octal
-
- 4023 security option duplicated
-
- 4024 two security options (unclassified, secret)
-
- 4025 two security options (secret, unclassified)
- 4026 security option with an invalid security level
-
- 4027 ordinary datagram after bad security option tests
-
- 4028 truncated stream identification option
-
- 4029 stream identification option length bumped by 1
-
- 4030 stream identification option one byte too long
-
- 4031 stream identification option one byte too short
-
- 4032 stream identification option length of 0
-
- 4033 stream identification option length of 377 octal
-
- 4034 stream identification option length of 354 octal
-
- 4035 stream identification option length of 177 octal
-
- 4036 stream identification option length of 200 octal
-
- 4037 stream identification option length of 204 octal
-
- 4038 stream identification option duplicated
-
- 4039 two different stream identification options
-
- 4040 bad security level + good stream identification option
-
- 4041 bad security length + good stream identification option
-
- 4042 ordinary datagram after bad stream ID option tests
-
- 4043 truncated record route option
-
- 4044 record route option length bumped by 1
-
- 4045 record route option one byte too long
-
- 4046 record route option one byte too short
-
- 4047 record route option length of 0
-
- 4048 record route option length of 377 octal
-
- 4049 record route option length of 353 octal
-
- 4050 record route option length of 177 octal
-
- 4051 record route option length of 200 octal
-
- 4052 record route option length of 207 octal
- 4053 record route option pointer bumped by 1
-
- 4054 record route option pointer one short
-
- 4055 record route option pointer of 300 octal
-
- 4056 record route option pointer of 174 octal
-
- 4057 record route option pointer with bad option length and
- option pointer
-
- 4058 record route option with bad option pointer
-
- 4059 larger record route option with bad option pointer
-
- 4060 record route option duplicated
-
- 4061 two different record route options
-
- 4062 ordinary datagram after bad record route option tests
-
- 4063 truncated timestamp option
-
- 4064 timestamp option length bumped by 1
-
- 4065 timestamp option one byte too long
-
- 4066 timestamp option one byte too short
-
- 4067 timestamp option length of 0
-
- 4068 timestamp option length of 374 octal
-
- 4069 timestamp option length of 354 octal
-
- 4070 timestamp option length of 174 octal
-
- 4071 timestamp option length of 200 octal
-
- 4072 timestamp option length of 210 octal
-
- 4073 timestamp option pointer bumped by 1
-
- 4074 timestamp option pointer one short
-
- 4075 timestamp option pointer of 301 octal
-
- 4076 timestamp option pointer of 175 octal
-
- 4077 timestamp option pointer with bad option length and
- option pointer
-
- 4078 timestamp option with bad option pointer
- 4079 larger timestamp option with bad option pointer
-
- 4080 timestamp option duplicated
-
- 4081 two different timestamp options
-
- 4082 timestamp option with bad timestamp option format
-
- 4083 truncated timestamp option
-
- 4084 timestamp option length bumped by 1
-
- 4085 timestamp option one byte too long
-
- 4086 timestamp option four bytes too short
-
- 4087 timestamp option four bytes too short
-
- 4088 timestamp option length of 374 octal
-
- 4089 timestamp option length of 354 octal
-
- 4090 timestamp option length of 174 octal
-
- 4091 timestamp option length of 200 octal
-
- 4092 timestamp option length of 214 octal
-
- 4093 timestamp option pointer bumped by 4
-
- 4094 timestamp option pointer four short
-
- 4095 timestamp option pointer of 305 octal
-
- 4096 timestamp option pointer of 175 octal
-
- 4097 timestamp option pointer with bad option length and
- option pointer
-
- 4098 timestamp option with bad option pointer
-
- 4099 ordinary datagram after bad timestamp option tests
-
-
-
- Test 4000 security option without copy bit set
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid security option without the
- copy bit set. The IUT is required to inform its Remote Driver
- that the request is invalid. The Remote Driver should then
- request the IUT to send an IP Remote Driver Specification
- error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4000 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4001 loose source and record route option without copy bit set
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid loose source and record route
- option without the copy bit set. The IUT is required to inform
- its Remote Driver that the request is invalid. The Remote
- Driver should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4001 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4002 timestamp option without bit 6 set
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver-should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid timestamp option without bit
- 6 set. The IUT is required to inform its Remote Driver that
- the request is invalid. The Remote Driver should then request
- the IUT to send an IP Remote Driver Specification error
- message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4002 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4003 stream ID option without copy bit set
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 4-byte option field. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid stream ID option without the
- copy bit set. The IUT is required to inform its Remote Driver
- that the request is invalid. The Remote Driver should then
- request the IUT to send an IP Remote Driver Specification
- error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4003 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4004 strict source and record route option without copy bit
- set
-
- - Can the IUT detect an option that isn't well-formed?
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with s 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid strict source and record
- route option without the copy bit set. The IUT is required to
- inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4004 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4005 "option" with option type of 77 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 4-byte option field. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid "option" with an option type
- of 77 octal. The IUT is required to inform its Remote Driver
- that the request is invalid. The Remote Driver should then
- request the IUT to send an IP Remote Driver Specification
- error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4005 error" in its 181-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4006 "option" with option type of 101 octal
- - Can She IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 4-byte option field. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid "option" with an option type
- of 101 octal. The IUT is required to inform its Remote Driver
- that the request is invalid. The Remote Driver should then
- request the IUT to send an IP Remote Driver Specification
- error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4006 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4007 "option" with option type of 177 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 4-byte option field. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid "option" with an option type
- of 177 octal. The IUT is required to inform its Remote Driver
- that the request is invalid. The Remote Driver should then
- request the IUT to send an IP Remote Driver Specification
- error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4007 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
- Test 4008 record route option with copy bit set
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid record route option with the
- copy bit set. The IUT is required to inform its Remote Driver
- that the request is invalid. The Remote Driver should then
- request the IUT to send an IP Remote Driver Specification
- error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4008 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4009 prespecified timestamp option with copy bit set
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid prespecified timestamp option
- with the copy bit set. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4009 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4010 end of options list option with copy bit set
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 4-byte option field. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid end of options list option
- with the copy bit set. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4010 error" in its 181
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4011 no operation option with copy bit set
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 4-byte option field. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid no operation option with the
- copy bit set. The IUT is required to inform its Remote Driver
- that the request is invalid. The Remote Driver should then
- request the IUT to send an IP Remote Driver Specification
- error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4011 error" in its 181
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4012 ordinary datagram after bad option type tests
-
- - Can the IUT send a datagram after processing nastygrams?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 4012 " in its 13-byte
- data field.
-
- Success: A reply datagram containing "ident = 4012 ".
-
- Failure: Any response other than the display of the
- requested reply datagram. The actual failure probably
- occurred during tests 4000-4011.
-
- Test 4013 truncated security option
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. The first two bytes of the option field requested to
- be sent are no operation options. They are followed by a
- truncated security option. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4013 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
- Test 4014 security option length bumped by 1
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid unclassified security option
- whose option length has been bumped by 1. The IUT is required
- to inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4014 error" in its 181
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4015 security option one byte too long
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid unclassified security option
- that is one byte too long. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4015 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4016 security option one byte too short
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid unclassified security option
- that is one byte too short. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4016 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4017 security option length of 0
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid unclassified security option
- whose option length has been set to 0. The IUT is required to
- inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4017 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4018 security option length of 377 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid unclassified security option
- whose option length has been set to 377 octal. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4018 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4019 security option length of 353 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid unclassified security option
- whose option length has been set to 353 octal. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4019 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4020 security option length of 177 octal
-
- 1 Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid unclassified security option
- whose option length has been set to 177 octal. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4020 error" in its 181
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4021 security option length of 200 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid unclassified security option
- whose option length has been set to 200 octal. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4021 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4022 security option length of 213 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid unclassified security option
- whose option length has been set to 213 octal. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4022 error" in its 181
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4023 security option duplicated
-
- - Can the IUT detect an option field that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 32-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains two identical and perfectly legal
- unclassified security options. The IUT is required to inform
- its Remote Driver that the request is invalid. The Remote
- Driver should then request the IUT to send an IP Remote Driver
- Specification error messsge to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4023 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4024 two security options
-
- - Can the IUT detect an option field that isn't well-formed?
-
- - Action: Send a datagram to tne IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 32-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains two different and perfectly legal
- security options. The IUT is required to inform its Remote
- Driver that the request is invalid. The Remote Driver should
- then request the IUT to send an IP Remote Driver Specification
- error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4024 error" in its 181
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4025 two security options
-
- - Can the IUT detect an option field that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 32-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains two different and perfectly legal
- security options in reverse order of test 4024. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4025 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4026 security option with an invalid security level
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid security option whose sole
- defect is an invalid security level. The IUT is required to
- inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4026 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4027 ordinary datagram after bad security option tests
-
- - Can the IUT send a datagram after processing nastygrams?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 4027 ~n its 13-byte
- data field.
-
- Success: A reply datagram containing "ident = 4027 ".
-
- Failure: Any response other than the display of the
- requested reply datagram. The actual failure probably
- occurred during tests 4013-4026.
-
- Test 4028 truncated stream identification option
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 4-byte option field. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. The first byte of the option field requested to be
- sent is a no operation option. This is followed by a truncated
- stream identification option. The IUT is required to inform
- its Remote Driver that the request is invalid. The Remote
- Driver should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4028 -error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4029 stream identification option length bumped by 1
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 4-byte option field. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid stream identification option
- whose option length has been bumped by 1. The IUT is required
- to inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4029 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4030 stream identification option one byte too long
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid stream identification option
- that is one byte too long. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4030 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4031 stream identification option one byte too short
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 4-byte option field. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid stream identification option
- that is one byte too short. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4031 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4032 stream identification option length of 0
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 4-byte option field. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid stream identification option
- whose option length is set to 0. The IUT is required to inform
- its Remote Driver that the request is invalid. The Remote
- Driver should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4032 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4033 stream identification option length of 377 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid stream identification option
- whose option length is set to 377 octal. The IUT is required
- to inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4033 error" in its 18-
- byte data field. The IP Tester should slso display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4034 stream identification option length of 353 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 4lbyte option field. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid stream identification option
- whose option length is set to 353 octal. The IUT is required
- to inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send sn IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4034 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4035 stream identification option length of 177 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 4-byte option field. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid stream identification option
- whose option length is set to 177 octal. The IUT is required
- to inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4035 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4036 stream identification option length of 200 octal
-
- 1 Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 4-byte option field. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid stream identification option
- whose option length is set to 200 octal. The IUT is required
- to inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4036 error" in its 181
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4037 stream identification option length of 204 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 4-byte option field. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid stream identification option
- whose option length is set to 204 octal. The IUT is required
- to inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4039 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4040 bad security option plus good stream identification
- option
-
- - Can the IUT detect an option field that isn't well-formed:
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 16-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a security option with an invalid
- security level and a legal stream ID option. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification- error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4040 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4041 bad security option plus good stream identification
- option
-
- - Can the IUT detect an option field that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 16-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a security option with an invalid option
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4039 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4040 bad security option plus good stream identification
- option
-
- - Can the IUT detect an option field that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 16-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a security option with an invalid
- security level and a legal stream ID option. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4040 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4041 bad security option plus good stream identification
- option
-
- - Can the IUT detect an option field that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 16-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a security option with an invalid option
- length and a legal stream ID option. The IUT is required to
- inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- 1 Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4041 error" in its 181
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4042 ordinary datagram after bad stream ID option tests
-
- - Can the IUT send a datagram after processing nastygrams?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 4042 " in its 13-byte
- data field.
-
- Success: A reply datagram containing "ident = 4042 ".
-
- Failure: Any response other than the display of the
- requested reply datagram. The actual failure probably
- occurred during tests 4028-4041.
-
- Test 4043 truncated record route option
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8lbyte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. The first two bytes of the option field requested to
- be sent are no operation options. They are followed by a
- truncated record route option. The IUT is required to inform
- its Remote Driver that the request is invalid. The Remote
- Driver should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4043 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4044 record route option length bumped by 1
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option whose option
- length has been bumped by 1. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4044 error" in its 181
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4045 record route option one byte too long
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option that is one byte
- too long. The IUT is required to inform its Remote Driver that
- the request is invalid. The Remote Driver should then request
- the IUT to send an IP Remote Driver Specification error
- message to the IP Tester.
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4045 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4046 record route option one byte too short
-
- 1 Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option that is one byte
- too short. The IUT is required to inform its Remote Driver
- that the request is invalid. The Remote Driver should then
- request the IUT to send an IP Remote Driver Specification
- error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4046 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4047 record route option length of 0
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option whose option
- length is set to 0. The IUT is required to inform its Remote
- Driver that the request is invalid. The Remote Driver should
- then request the IUT to send an IP Remote Driver Specification
- error message to the IP Tester.
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4047 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4048 record route option length of 377 octal
-
- 1 Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option whose option
- length is set to 377 octal. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4048 error" in its 181
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4049 record route option length of 353 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option whose option
- length is set to 353 octal. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4049 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4050 record route option length of 177 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option whose option
- length is set to 177 octal. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4050 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4051 record route option length of 200 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option whose option
- length is set to 200 octal. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4051 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4052 record route option length of 207 octal
-
- 1 Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option whose option
- length is set to 207 octal. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4052 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4053 record route option pointer bumped by 1
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option whose option
- pointer is one more than it should be. The IUT is required to
- inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4053 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4054 record route option pointer one short
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option whose option
- pointer is one less than it should be. The IUT is required to
- inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4054 error" in its 181
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4055 record route option pointer of 300 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option whose option
- pointer is set to 300 octal. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4055 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4056 record route option pointer of 174 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option whose option
- pointer is set to 174 octal. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4056 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4057 record route option with bad option length and option
- pointer
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option whose option
- length and option pointer have both been bumped by 12. The IUT
- is required to inform its Remote Driver that the request is
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4055 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4056 record route option pointer of 174 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option whose option
- pointer is set to 174 octal. The IUT is required to inform its
- Remote Driver that the request is invalid. The Remote Driver
- should then request the IUT to send an IP Remote Driver
- Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4056 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4057 record route option with bad option length and option
- pointer
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option whose option
- length and option pointer have both been bumped by 12. The IUT
- is required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4057 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4058 record route option with bad option pointer
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a record route option whose option
- pointer just exceeds its maximum legal value. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4058 error" in its 181
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4059 record route option with bad option pointer
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a two address field record route option
- whose option pointer just exceeds its maximum legal value. The
- IUT is required to inform its Remote Driver that the request
- is invalid. The Remote Driver should then request the IUT to
- send an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4059 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4060 record route option duplicated
-
- - Can the IUT detect an option field that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 24-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains two identical and perfectly legal record
- route options. The IUT is required to inform its Remote Driver
- that the request is invalid. The Remote Driver should then
- request the IUT to send an IP Remote Driver Specification
- error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4060 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4061 two record route options
-
- - Can the IUT detect an option field that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 28-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains two perfectly legal but different record
- route options. The IUT is required to inform its Remote Driver
- that the request is invalid. The Remote Driver should then
- request the IUT to send an IP Remote Driver Specification
- error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4061 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4062 ordinary datagram after bad record route option tests
-
- - Can the IUT send a datagram after processing nastygrams?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 4062 " in its 13-byte
- data field.
-
- Success: A reply datagram containing "ident = 4062 ".
-
- Failure: Any response other than the display of the
- requested reply datagram. The actual failure probably
- occurred during tests 4043-4061.
-
- Test 4063 truncated timestamp option
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8lbyte option field. This datagram should
- be passed by tne IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. The first byte of the option field requested to be
- sent is a no operation option. It is followed by a truncated
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid timestamp only timestamp
- option that is one byte too long. The IUT is required to
- inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4065 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4066 timestamp option one byte too short
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid timestamp only timestamp
- option that is one byte too short. The IUT is required to
- inform its Remote Driver that the request is invalid. The
- Remote Driver should, then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4066 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4067 timestamp option length of 0
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid timestamp only timestamp
- option whose option length is set to 0. The IUT is required to
- inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4067 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4068 timestamp option length of 374 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid timestamp only timestamp
- option whose option length is set to 374 octal. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4068 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4069 timestamp option length of 354 octal
-
- - Can the IUT detect an option that isn't well-formed?
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid timestamp only timestamp
- option whose option length is set to 354 octal. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4069 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4070 timestamp option length of 174 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid timestamp only timestamp
- option whose option length is set to 174 octal. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- 1 Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4070 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
- Test 4071 timestamp option length of 200 octal
-
- - Can the IUT detect an optiom that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid timestamp only timestamp
- option whose option length is set to 200 octal. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4071 error" in its 181
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4072 timestamp option length of 210 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid timestamp only timestamp
- option whose option length is set to 210 octal (sign bit set).
- The IUT is required to inform its Remote Driver that the
- request is invalid. The Remote Driver should then request the
- IUT to send an IP Remote Driver Specification error message to
- the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4072 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4073 timestamp option pointer bumped by 1
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid timestamp only timestamp
- option whose option pointer is one more than it should be. The
- IUT is required to inform its Remote Driver that the request
- is invalid. The Remote Driver should then request the IUT to
- send an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4073 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4074 timestamp option pointer one short
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid timestamp only timestamp
- option whose option pointer is one less than it should be. The
- IUT is required to inform its Remote Driver that the request
- is invalid. The Remote Driver should then request the IUT to
- send an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4074 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4075 timestamp option pointer of 301 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid timestamp only timestamp
- option whose option pointer is set to 301 octal. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4075 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4076 timestamp option pointer of 175 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid timestamp only timestamp
- option whose option pointer is set to 175 octal. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4076 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4077 timestamp option with bad option length and option
- pointer
-
- - Can the IUT detect an option that isn't well-formed?-
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a timestamp only timestamp option whose
- option length and option pointer have both been bumped by 12.
- The IUT is required to inform its Remote Driver that the
- request is invalid. The Remote Driver should then request the
- IUT to send an IP Remote Driver Specification error message to
- the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4077 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4078 timestamp option with bad option pointer
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an 8-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid timestamp only timestamp
- option whose option pointer just exceeds its maximum legal
- value. The IUT is required to inform its Remote Driver that
- the request is invalid. The Remote Driver should then request
- the IUT to send an IP Remote Driver Specification error
- message to the IP Tester.
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The LP Tester will display the error message
- datagram that must contain "ident = 4080 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4081 two timestamp options
-
- 1 Can the IUT detect an option field that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 28-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains two perfectly legal but different
- timestamp only timestamp options. The IUT is required to
- inform its Remote Driver that the request is invalid. The-
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4081 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4082 timestamp option with bad timestamp option format
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains a timestamp option with an invalid
- format value. The IUT is required to inform its Remote Driver
- that the request is invalid. The Remote Driver should then
- request the IUT to send an IP Remote Driver Specification
- error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4082 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4083 truncated timestamp option
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. The first byte of the option field requested to be
- sent is a no operation option. It is followed by a truncated
- address and timestamp timestamp option. The IUT is required to
- inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4083 error" in its 18-
- byte-data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4084 timestamp option length bumped by 1
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid prespecified timestamp option
- whose option length is one more than it should be. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4084 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4085 timestamp option one byte too long
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 16-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid address and timestamp
- timestamp option that is one byte too long. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4085 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4086 timestamp option four bytes too short
-
- - Can the IUT detect an option that isn't well-formed?
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 16-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid prespecified timestamp option
- whose second timestamp field has been removed. The IUT is
- required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4086 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4087 timestamp option four bytes too short
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 16-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid address and timestamp
- timestamp option whose second timestamp field has been
- removed. The IUT is required to inform its Remote Driver that
- the request is invalid. The Remote Driver should then request
- the IUT to send an IP Remote Driver Specification error
- message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4087 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
- Test 4088 timestamp option length of 374 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 16-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid prespecified timestamp option
- whose option length is set to 374 octal. The IUT is required
- to inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4088 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4089 timestamp option length of 354 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid address and timestamp
- timestamp option whose option length is set to 354 octal. The
- IUT is required to inform its Remote Driver that the request
- is invalid. The Remote Driver should then request the IUT to
- send an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4089 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4090 timestamp option length of 174 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid prespecified timestamp option
- whose option length is set to 174 octal. The IUT is required
- to inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4090 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4091 timestamp option length of 200 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid address and timestamp
- timestamp option whose option length is set to 200 octal. The
- IUT is required to inform its Remote Driver that the request
- is invalid. The Remote Driver should then request the IUT to
- send an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4091 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4092 timestamp option length of 214 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid prespecified timestamp option
- whose option length is set to 214 octal (sign bit set). The
- IUT is required to inform its Remote Driver that the request
- is invalid. The Remote Driver should then request the IUT to
- send an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4092 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4093 timestamp option pointer bumped by 4
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid address and timestamp
- timestamp option whose option pointer is four more than it
- should be. The IUT is required to inform its Remote Driver
- that the request is invalid. The Remote Driver should then
- request the IUT to send an IP Remote Driver Specification
- error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4093 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4094 timestamp option pointer four short
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid prespecified timestamp option
- whose option pointer is four less than it should be. The IUT
- is required to inform its Remote Driver that the request is
- invalid. The Remote Driver should then request the IUT to send
- an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4094 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4095 timestamp option pointer of 305 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid address and timestamp
- timestamp option whose option pointer is set to 305 octal. The
- IUT is required to inform its Remote Driver that the request
- is invalid. The Remote Driver should then request the IUT to
- send an IP Remote Driver Specification error message to the IP
- Tester.
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4095 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4096 timestamp option pointer of 175 octal
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid prespecified timestamp option
- whose option pointer is set to 175 octal. The IUT is required
- to inform its Remote Driver that the request is invalid. The
- Remote Driver should then request the IUT to send an IP Remote
- Driver Specification error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4096 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4097 timestamp option with bad option length and option
- pointer
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid address and timestamp
- timestamp option whose option length and option pointer have
- been bumped by 16. The IUT is required to inform its Remote
- Driver that the request is invalid. The Remote Driver should
- then request the IUT to send an IP Remote Driver Specification
- error message to the IP Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4097 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4098 timestamp option with bad option pointer
-
- - Can the IUT detect an option that isn't well-formed?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a 12-byte option field. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester. This contains an invalid prespecified timestamp option
- whose option pointer just exceeds its maximum legal value. The
- IUT is required to inform its Remote Driver that the request
- is invalid. The Remote Driver should then request the IUT to
- send an IP Remote Driver Specification error message to the IP
- Tester.
-
- - Verification: The IP Tester will display the error message
- datagram that must contain "ident = 4098 error" in its 18-
- byte data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the error message datagram does not contain
- the invalid option field in its IP header.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Test 4099 ordinary datagram after bad timestamp option tests
-
- - Can the IUT send a datagram after processing nastygrams?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 4099
- data field.
-
- Success: A reply datagram containing "ident = 4099 ".
-
- Failure: Any response other than the display of the
- requested reply datagram. The actual failure probably
- occurred during tests 4063-4098.
- Scenario File OptGdBotTest: "Bottom-up Good Option Field" datagrams
-
- 1000 end of options list option
-
- 1001 no operation option
-
- 1002 two no operation options
-
- 1003 three no operation options
-
- 1004 four no operation options
-
- 1005 unclassified security option
-
- 1006 confidential security option
-
- 1007 EFTO security option
-
- 1008 MMMM security option
-
- 1009 PROG security option
-
- 1010 restricted security option
-
- 1011 secret security option
-
- 1012 top secret security option
-
- 1013 stream ID option with an ID of 0
-
- 1014 stream ID option with an ID of 64
-
- 1015 stream ID option with an ID of 128
-
- 1016 stream ID option with an ID of 255
-
- 1017 stream ID option with an ID of 16384
-
- 1018 stream ID option with an ID of 16448
-
- 1019 stream ID option with an ID of 16512
-
- 1020 stream ID option with an ID of 16639
-
- 1021 stream ID option with an ID of 32768
-
- 1022 stream ID option with an ID of 32832
-
- 1023 stream ID option with an ID of 32896
-
- 1024 stream ID option with an ID of 33023
-
- 1025 stream ID option with an ID of 65280
- 1026 stream ID option with an ID of 65344
-
- 1027 stream ID option with an ID of 65408
-
- 1028 stream ID option with an ID of 65535
-
- 1029 stream ID option with an ID of 43605
-
- 1030 stream ID option with an ID of 21930
-
- 1031 mixture of good options
-
- 1032 one address record route option
-
- 1033 two address record route option
-
- 1034 nine address record route option
-
- 1035 fragmented datagram with nine address record route option
-
- 1036 eight btye timestamp only option
-
- 1037 16 byte timestamp only option
-
- 1038 44 byte timestamp only option
-
- 1039 fragmented datagram with 44 byte timestamp only option
-
- 1040 12 byte address timestamp and addressoption
-
- 1041 20 byte timestamp and address option
-
- 1042 36 byte timestamp and address option
-
- 1043 fragmented datagram with 36 byte timestamp and address
- option
-
- 1044 12 byte prespecified timestamp option
-
- 1045 20 byte prespecified timestamp option
-
- 1046 28 byte prespecified timestamp option
-
- 1047 fragmented datagram with 36 byte prespecified timestamp opti
-
-
-
- Test 1000 end of options list option
-
- - Can the IUT receive a datagram with end of options list option
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing an end of options list option. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote Drive
- should request the IUT to send the reply datagram required by
- the IP Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1000 " in its 13-byte
- data field. The IP Tester should also display "HL5"
- (internet header length is 5 four-octet units long) to
- indicate that the reply datagram does not contain an option
- field in its IP header.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1001 no operation option
-
- - Can the IUT receive a datagram with a no operation option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a no operation option. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1001 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1002 two no operation options
-
- - Can the IUT receive a datagram with two no operation
- options?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing two no operation options. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1002 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1003 three no operation options
-
- - Can the IUT receive a datagram with three no operation
- options?
-
- - Action: Send a datagram to the IP Implementatiom Under Test
- containing three no operation options. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1003 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1004 four no operation options
-
- - Can the IUT receive a datagram with four no operation
- options?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing four no operation options. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1004 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1005 unclassified security option
-
- - Can the IUT receive a datagram with an unclassified security
- option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing an unclassified security option. This datagram
- should be passed by the IUT to its Remote Driver. The IUT's
- Remote Driver should request the IUT to send the reply
- datagram required by the IP Remote Driver Specification to the
- IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1005 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1006 confidential security option
-
- - Can the IUT receive a datagram with a confidential security
- option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a confidential security option. This datagram
- should be passed by the IUT to its Remote Driver. The IUT's
- Remote Driver should request the IUT to send the reply
- datagram required by the IP Remote Driver Specification to the
- IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1006 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1007 EFTO security option
-
- - Can the IUT receive a datagram with an EFTO security
- option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing an EFTO security option. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1007 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
- Test 1008 MMMM security option
-
- - Can the IUT receive a datagram with a MMMM security option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a MMMM security option. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1008 " in Its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1009 PROG security option
-
- - Can the IUT receive a datagram with a PROG security option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a PROG security option. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1009 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1010 restricted security option
-
- - Can the IUT receive a datagram with a restricted security
- option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a restricted security option. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1010 " in its 13-byte
- data field.
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1011 secret security option
-
- - Can the IUT receive a datagram with a secret security
- option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a secret security option. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1011 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1012 top secret security option
-
- - Can the IUT receive a datagram with a top secret security
- option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a top secret security option. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1012 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1013 stream ID option with an ID of 0
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream lD option whose ID bytes are clear. This
- datagram should be passed by the IUT to its Remote Driver. The
- IUT's Remote Driver should request the IUT to send the reply
- datagram required by the IP Remote Driver Specification to the
- IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1013 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1014 stream ID option with an ID of 64
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option (upper ID byte clear, lower ID
- byte 100 octal). This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1014 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1015 stream ID option with an ID of 128
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option (upper ID byte clear, lower ID
- byte sign bit set.) This datagram should be passed by the IUT
- to its Remote Driver. The IUT's Remote Driver should request
- the IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1015 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1016 stream ID option with an ID of 255
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option (upper ID byte clear, lower ID
- byte bits set). This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1016 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1017 stream ID option with an ID of 16384
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option (upper ID byte 100 octal, lower
- ID byte clear). This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1017 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1018 stream ID option with an ID of 16448
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option whose ID bytes are set to 100
- octal. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- - Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1018 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1019 stream ID option with an ID of 16512
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option (upper ID byte 100 octal, lower
- ID byte sign bit set). This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1019 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1020 stream ID option with an ID of 16639
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option (upper ID byte 100 octal, Lower
- ID byte bits set). This datagram should be passed by the IUT
- to its Remote Driver. The IUT's Remote Driver should request
- the IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1020 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1021 stream ID option with an ID of 32768
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option (upper ID byte sign bit set,
- lower ID byte clear). This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1021 " in
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1022 stream ID option with an ID of 32832
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option (upper ID byte sign bit set,
- lower ID byte 100 octal). This datagram should be passed by
- the IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1022 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1023 stream ID option with an ID of 32896
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option whose ID bytes have their sign
- bits set. This datagram should be passed by the IUT to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1023 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1024 stream ID option with an ID of 33023
-
- - Can the IUT receive a datagram with a stream ID option?
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option (upper ID byte sign bit set,
- lower ID byte bits set.) This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1024 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1025 stream ID option with an ID of 65280
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option (upper ID byte bits set, lower
- ID byte clear). This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1025" in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1026 stream ID option with an ID of 65344
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option (upper ID byte bits set, lower
- ID byte 100 octal.) This datagram should be passed by the IUT
- to its Remote Driver. The IUT's Remote Driver should request
- the IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1026" in its 13-byte
- data field.
-
- Success: Display of reply datagram.
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1027 stream ID option with an ID of 65408
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option (upper ID byte bits set, lower
- ID byte sign bit set). This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1027 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1028 stream ID option with an ID of 65535
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option whose ID bytes have all their
- bits set. This datagram should be passed by the IUT to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1028 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1029 stream ID option with an ID of 43605
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option with alternating ID bits set.
- This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
- Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1029 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1030 stream ID option with an ID of 21930
-
- - Can the IUT receive a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a stream ID option with alternating ID bits set.
- This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1030 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1031 mixture of good options
-
- - Can the IUT receive a datagram with a mixture of options?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing an unclassified security option, a no operation
- option, and a stream ID option. This datagram should be passed
- by the IUT to its Remote Driver. The IUT's Remote Driver
- should request the IUT to send the reply datagram required by
- the IP Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1031" in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1032 one address record route option
-
- - Can the IUT receive a datagram with a record route option?
- - Action: Send a datagram to the IP Implementation Under Test
- containing a perfectly legal one address field record route
- option. This datagram should be passed by the IUT to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagram required by the lP Remote Driver
- Specification to the lP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1032" in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1033 two address record route option
-
- - Can the IUT receive a datagram with a record route option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a perfectly legal two address field record route
- option. This datagram should be passed by the IUT to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1033." in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1034 nine address record route option
-
- - Can the IUT receive a datagram with a record route option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a perfectly legal nine address field record route
- option. This datagram should be passed by the IUT to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the-reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1034 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1035 fragmented datagram with nine address record route option
-
- - Can the IUT reassemble a datagram with a record route
- option?
-
- - Action: Send a fragmented datagram to the IP Implementation
- Under Test containing a perfectly legal nine address field
- record route option. This datagram should be passed by the IUT
- to its Remote Driver. The IUT's Remote Driver should request
- the IUT to send the reply datagram required by the IP-Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1035 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1036 eight byte timestamp only option
-
- - Can the IUT receive a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a perfectly legal eight byte timestamp only
- timestamp option. This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1036 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1037 12 byte timestamp option
-
- - Can the IUT receive a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a perfectly legal 12 byte timestamp only timestamp
- option. This datagram should be passed by the IUT to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1037 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1038 44 byte timestamp option
-
- - Can the IUT receive a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a perfectly legal 44 byte field timestamp only
- timestamp option. This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1038 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1039 fragmented datagram with 44 byte timestamp only option
-
- - Can the IUT reassemble a datagram with a timestamp option?
-
- - Action: Send a fragmented datagram to the IP Implementation
- Under Test containing a perfectly legal timestamp only
- timestamp option. This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1039 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1040 12 byte timestamp and address option
-
- - Can the IUT receive a datagram with a timestamp option?
- - Action: Send a datagram to the IP Implementation Under Test
- containing a perfectly legal 12 byte timestamp and address
- option. This datagram should be passed by the IUT to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1040 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1041 20 byte timestamp and address
-
- - Can the IUT receive a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a perfectly legal 20 byte timestamp and address
- option. This datagram should be passed,by the IUT to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1041 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1042 36 byte timestamp and address option
-
- - Can the IUT receive a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a perfectly legal 36 byte timestamp and address
- option. This datagram should be passed by the IUT to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1042 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1043 fragmented datagram with 36 byte timestamp and address
- option
-
- - Can the IUT reassemble a datagram with a timestamp option?
-
- - Action: Send a fragmented datagram to the IP Implementation
- Under Test containing a perfectly legal 36 byte timstamp and
- address option. This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1043 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1044 12 byte prespecified timestamp option
-
- - Can the IUT receive a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a perfectly legal 12 byte field prespecified
- timestamp option. This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 1044 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 1045 20 byte prespecified option
-
- - Can the IUT receive a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a perfectly legal 20 bytes prespecified timestamp
- option. This datagram should be passed by the IUT to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
- 3028 stream ID option with an ID of 65535
-
- 3029 stream ID option with an ID of 43605
-
- 3030 stream ID option with an ID of 21930
-
- 3031 mixture of good options
-
- 3032 one address record route option
-
- 3033 two address record route option
-
- 3034 nine address record route option
-
- 3035 fragmented datagram with nine address record route option
-
- 3036 eight byte timestamp only option
-
- 3037 16 byte timestamp only option
-
- 3038 44 byte timestamp only option
-
- 3039 fragmented datagram with 44 byte timestamp only option
-
- 3040 12 byte timestamp only option
-
- 3041 20 byte timestamp option
-
- 3042 36 byte timestamp option
-
- 3043 fragmented datagram with 36 byte timestamp option
-
- 3044 12 byte prespecified timestamp option
-
- 3045 20 byte prespecified timestamp option
-
- 3046 36 byte prespecified timestamp option
-
- 3047 fragmented datagram with 36 byte prespecified timestamp
- option
-
-
-
- Test 3000 end of options list option
-
- - Can the IUT send a datagram with end of options list
- option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an end of options list option. This datagram
- should be passed by the IUT to its Remote Driver. The IUT's
- Remote Driver should request the IUT to send the reply
- datagram required by the IP Remote Driver Specification to the
- IP Tester.
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3000 in
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3001 no operation option
-
- - Can the IUT send a datagram with a no operation option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a no operation option. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3001 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3002 two no operation options
-
- - Can the IUT send a datagram with two no operation options?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with two no operation options. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IF Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3002 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other tham the display of the reply
- datagram.
-
- Test 3003 three no operation options
- - Can the IUT send a datagram with three no operation
- options?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with three no operation options. This datagram
- should be passed by the IUT to its Remote Driver. The IUT's
- Remote Driver should request the IUT to send the reply
- datagram required by the IP Remote Driver Specification to the
- IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3003 " in its 13=byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3004 four no operation options
-
- - Can the IUT send a datagram with four no operation options?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with four no operation options. This datagram
- should be passed by the IUT to its Remote Driver. The IUT's
- Remote Driver should request the IUT to send the reply
- datagram required by the IP Remote Driver Specification to the
- IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3004 " in its 13-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3005 unclassified security option
-
- - Can the IUT send a datagram with an unclassified security
- option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an unclassified security option. This datagram
- should be passed by the IUT to its Remote Driver. The IUT's
- Remote Driver should request the IUT to send the reply
- datagram required by the IP Remote Driver Specification to the
- IP Tester.
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3005 " in its 13-byte
- data field. The display should also contain "SEC UNCL
- comp=00000 hand=hh tcc=tcc".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3006 confidential security option
-
- - Can the IUT send a datagram with a confidential security
- option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a confidential security option. This datagram
- should be passed by the IUT to its Remote Driver. The IUT's
- Remote Driver should request the IUT to send the reply
- datagram required by the IP Remote Driver Specification to the
- IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3006 " in its 13-byte
- data field. The display should also contain "SEC CONF
- comp=00000 hand=hh tcc=tcc".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3007 EFTO security option
-
- - Can the IUT send a datagram with an EFTO security option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an EFTO security option. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- -Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3007 " in its 13-byte
- data field. The display should also contain "SEC EFTO
- comp=00000 hand=hh tcc=tcc".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
- Test 3008 MMMM security option
-
- - Can the IUT send a datagram with a MMMM security option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a MMMM security option. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3008 " in its 13-byte
- data field. The display should also contain "SEC MMMM
- comp=00000 hand=hh tcc=tcc".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3009 PROC security option
-
- - Can the IUT send a datagram with a PROC security option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a PROG security option. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3009 " in its 13-byte
- data field. The display should also contain "SEC PROC
- comp=00000 hand=hh tcc=tcc".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3010 restricted security option
-
- - Can the IUT send a datagram with a restricted security
- option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a restricted security option. This datagram
- should be passed by the IUT to its Remote Driver. The IUT's
- Remote Driver should request the IUT to send the reply
- datagram required by the IP Remote Driver Specification to the
- IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3010 " in its 13-byte
- data field. The display should also contain "SEC REST
- comp=00000 hand=hh tcc=tcc".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3011 secret security option
-
- - Can the IUT send a datagram with a secret security option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a secret security option. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3011 " in its 13-byte
- data field. The display should also contain "SEC SECT
- comp=00000 hand=hh tcc=tcc".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3012 top secret security option
-
- - Can the IUT send a datagram with a top secret security
- option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a top secret security option. This datagram
- should be passed by the IUT to its Remote Driver. The IUT's
- Remote Driver should request the IUT to send the reply
- datagram required by the IP Remote Driver Specification to the
- IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3012 " in its 13-byte
- data field. The display should also contain "SEC TSEC
- comp=00000 hand=hh tcc=tcc".
-
- Success: Display of reply datagram.
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3013 stream ID option with an ID of 0
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option whose ID bytes are clear.
- This datagram should be passed by the IUT to its. Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3013 " in its 13-byte
- data field. The display should also contain "STREAM 00000".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3014 stream ID option with an ID of 64
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option (upper ID byte clear, lower
- ID byte 100 octal). This datagram should be passed by the IUT
- to its Remote Driver. The IUT's Remote Driver should request
- the IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3014 " in its 13 byte
- data field. The display should also contain "STREAM 00064".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3015 stream ID option with an ID of 128
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option (upper ID byte clear, lower
- ID byte sign bit set). This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3015 " in its 13-byte
- data field. The display should also contain "STREAM 00128".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3016 stream ID option with an ID of 255
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option (upper ID byte clear, lower
- ID byte bits set). This datagram should be passed by the IUT
- to its Remote Driver. The IUT's Remote Driver should request
- the IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3016 " in its 13-byte
- data field. The display should also contain "STREAM 00255".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3017 stream ID option with an ID of 16384
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option (upper ID byte 100 octal,
- lower ID byte clear.) This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3017 " in its 13-byte
- data field. The display should also contain "STREAM 16384".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
- Test 3018 stream ID option with an ID of 16448
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option whose ID bytes are set to
- 100 octal. This datagram should be passed by the IUT to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3018 " in its 13-byte
- data field. The display should also contain "STREAM 16448".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3019 stream ID option with an ID of 16512
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option (upper ID byte 100 octal,
- lower ID byte sign bit set). This datagram should be passed
- by the IUT to its Remote Driver. The IUTs Remote Driver
- should request the IUT to send the reply datagram required by
- the IP Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3019 " in its 13-byte
- data field. The display should also contain "STREAM 16512".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3020 stream ID option with an ID of 16639
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option (upper ID byte 100 octal,
- lower ID byte bits set). This datagram should be passed by
- the IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3020 " in its 13-byte
- data field. The display should also contain "STREAM 16639".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3021 stream ID option with an ID of 32768
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option (upper ID byte sign bit
- set, lower ID byte clear). This datagram should be passed by
- the IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3021 " in its 13-byte
- data field. The display should also contain "STREAM 32768".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3022 stream ID option with an ID of 32832
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option (upper ID byte sign bit
- set, lower ID byte 100 octal). This datagram should be passed
- by the IUT to its Remote Driver. The IUT's Remote Driver
- should request the IUT to send the reply datagram required by
- the IP Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3022 " in its 13-byte
- data field. The display should also contain "STREAM 32832".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3023 stream ID option with an ID of 32896
-
- - Can the IUT send a datagram with a stream ID option?
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option whose ID bytes have their
- sign bits set. This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3023 " in its 13-byte
- data field. The display should also contain "STREAM 32896".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3024 stream ID option with an ID of 33023
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option (upper ID byte sign bit
- set, lower ID byte bits set). This datagram should be passed
- by the IUT to its Remote Driver. The IUT's Remote Driver
- should request the IUT to send the reply datagram required by
- the IP Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3024 " in its 13-byte
- data field. The display should also contain "STREAM 33023".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3025 stream ID option with an ID of 65280
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option (upper ID byte bits set,
- lower ID byte clear). This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3025 " in its 13-byte
- data field. The display should also contain "STREAM 65280".
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3026 stream ID option with an ID of 65344
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option (upper ID byte bits set,
- lower ID byte 100 octal). This datagram should be passed by
- the IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the repIy datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3026 " in its 13-byte
- data field. The display should also contain "STREAM 65344".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3027 stream ID option with an ID of 65408
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option (upper ID byte bits set,
- lower ID byte sign bit set.) This datagram should be passed by
- the IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3027 " in its 13-byte
- data field. The display should also contain "STREAM 65408".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3028 stream ID option with an ID of 65535
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option whose ID bytes have all
- their bits set. This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3028 " in its 13-byte
- data field. The display should also contain "STREAM 65535".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3029 stream ID option with an ID of 43605
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option with alternating ID bits
- set. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3029 " in its 13-byte
- data field. The display should also contain "STREAM 43605".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3030 stream ID option with an ID of 21930
-
- - Can the IUT send a datagram with a stream ID option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a stream ID option with alternating ID bits
- set. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3030 " in its 13-byte
- data field. The display should also contain "STREAM 21930".
-
- Success: Display of reply datagram.
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3031 mixture of good options
-
- - Can the IUT send a datagram with a mixture of options?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with an unclassified security option, a no
- operation option, and a stream ID option. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3031 " in its 13-byte
- data field. The display should also contain "SEC UNCL
- comp=00000 hand=hh tcc=tcc" followed by "STREAM 21930".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3032 one address record route option
-
- - Can the IUT send a datagram with a record route option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a perfectly legal one address field record
- route option. This datagram should be passed by the IUT to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3032 " in its 13-byte
- data field. The display should also contain "ROUTE len=007
- ptr=004 00000000000".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3033 two address record route option
-
- - Can the IUT send a datagram with a record route option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a perfectly legal two address field record
- route option. This datagram should be passed by the IUT to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3033 " in its 13-byte
- data field. The display should also contain "ROUTE len=011
- ptr=004 00000000000 00000000000,.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3034 nine address record route option
-
- - Can the IUT send a datagram with a record route option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a perfectly legal nine address field record
- route option. This datagram should be passed by the IUT to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3034 ." in its 13-byte
- data field. The display should also contain "ROUTE len=039
- ptr=004 00000000000 00000000000 00000000000 00000000000
- 00000000000 00000000000 00000000000 00000000000
- 00000000000,.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3036 eight byte timestamp only option
-
- - Can the IUT send a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a perfectly legal eight byte timestamp only
- timestamp option. This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3036 " in its 13-byte
- data field. The display should also contain "TIMESTAMP
- len=008 ptr=005 ovr=00 TIMSO 00000000000".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3037 12 byte timestamp only option
-
- - Can the IUT send a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a perfectly legal two timestamp field
- timestamp only timestamp option. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3D37 " in its 13-byte
- data field. The display should also contain "TIMESTAMP
- len=012 ptr=005 ovr=00 TIMSO 00000000000000000000000,.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3038 44 byte timestamp only option
-
- - Can the IUT send a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under
- Test containing a Remote Driver command request for the IUT
- to send a datagram with a perfectly Iegal 44 byte field
- timestamp only timestamp option. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3038 " in its 13-byte
- data field. The display should also contain "TIMESTAMP
- len=040 ptr=005 ovr=00 TIMSO 00000000000 00000000000
- 00000000000 00000000000 00000000000 00000000000 00000000000
- 00000000000 00000000000,.
-
- Success: Display of reply datagram.
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3040 12 byte timestamp and address option
-
- - Can the IUT send a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a perfectly legal 12 byte option. This
- datagram should be passed by the IUT to its Remote Driver. The
- IUT's Remote Driver should request the IUT to send the reply
- datagram required by the IP Remote Driver Specification to the
- IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3040 " in its 13-byte
- data field. The display should also contain "TIMESTAMP
- len=012 ptr=005 ovr=00 ALLGT 00000000000 00000000000".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3041 20 byte timestamp and address option
-
- - Can the IUT send a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a perfectly legal 20 byte timestamp and
- address option. This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3041 " in its 13-byte
- data field. The display should also contain "TIMESTAMP
- len=020 ptr=005 ovr=00 ALLOT 00000000000 00000000000
- 00000000000 00000000000,.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3042 44 byte tinestamp and address option
-
- - Can the IUT send a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a perfectly legal four timestamp field address
- and timestamp timestamp option. This datagram should be passed
- by the IUT to its Remote Driver. The IUT's Remote Driver
- should request the IUT to send the reply datagram required by
- the IP Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3042 " in its 13-byte
- data field. The display should also contain "TIMESTAMP
- len=036 ptr=005 ovr=00 ALLGT 00000000000 00000000000
- 00000000000000000000000 00000000000 00000000000 00000000000
- 00000000000,.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3044 12 byte prespecified timestamp option
-
- - Can the IUT send a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a perfectly legal 12 byte prespecified
- timestamp option. This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3044 " in its 13-byte
- data field. The display should also contain "TIMESTAMP
- len=012 ptr=005 ovr=00 MATCM 01200200001 00000000000".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3045 two timestamp timestamp option
-
- - Can the IUT send a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a perfectly legal 20 byte prespecified
- timestamp option. This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3045 " in its 13-byte
- data field. The display should also contain "TIMESTAMP
- len=020 ptr=005 ovr=00 MATCH 01200200001 00000000000
- 00700200002 00000000000,.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 3046 28 byte prespecified option
-
- - Can the IUT send a datagram with a timestamp option?
-
- - Action: Send a datagram to the IP Implementation Under Test
- containing a Remote Driver command request for the IUT to send
- a datagram with a perfectly legal 36 byte prespecified
- timestamp option. This datagram should be passed by the IUT to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 3046 " in its 13-byte
- data field. The display should also contain "TIMESTAMP
- 1en=028 ptr=005 ovr=00 MATCH 00701400002 00000000000
- 01200200001 00000000000 00700200002 00000000000".
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
- Scenario File PrecBotTest: "Bottom-up Precedence Test" datagrams
-
- WARNING: This test depends on the IMPs to deliver a successive
- datagram with a lower precedence than a preceding datagram after
- the preceding datagram. A failure of the network to deliver the
- datagrams as indicated is primarily a reflection of the quality the
- network and not of the IUT. The IUT is only required to accept all
- eight datagrams and send eight reply datagrams. As of the date this
- was written, this test has never failed to deliver the indicated
- results.
-
- 200 precedence 7
-
- 201 precedence 6
-
- 202 precedence 5
-
- 203 precedence 4
-
- 204 precedence 3
-
- 205 precedence 2
-
- 206 precedence 1
-
- 207 precedence 0
-
-
-
-
- Test 200 precedence 7
-
- - Can the IUT receive a datagram with precedence 7?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a precedence of 7. This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 200 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 201 precedence 6
-
- - Can the IUT receive a datagram with precedence 6?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a precedence of 6. This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 201 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 202 precedence 5
-
- - Can the IUT receive a datagram with precedence 5?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a precedence of 5. This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 202 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 203 precedence 4
-
- - Can the IUT receive a datagram with precedence 4?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a precedence of 4. This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 203 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 204 precedence 3
-
- - Can the IUT receive a datagram with precedence 3?
- - Action: Send a datagram to the IP Implementation Under Test
- with a precedence of 3. This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 204 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 205 precedence 2
-
- - Can the IUT receive a datagram with precedence 2?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a precedence of 2. This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 205 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 206 precedence 1
-
- - Can the IUT receive a datagram with precedence 1?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a precedence of 1. This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 206 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 207 precedence 0
- - Can the IUT receive a datagram with precedence 0?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a precedence of 0. This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 207 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Scenario File PrecEffTest: "Precedence Effect Test" datagrams
-
- NOTICE: The race conditions introduced by precedence are to be
- considered desirable. The more out of order the reply datagrams
- are, the better the system is
-
- 216 precedence effect
-
-
-
-
- Test 216 precedence effect
-
- - Can the IUT take advantage of network precedence?
-
- - Action: The IP Tester will send eight datagrams in order of
- increasing precedence to the IUT. The IUT should pass each one
- to its Remote Driver that should send each reply datagram
- required by the IP Remote Driver Specification at the same
- precedence as each datagram received by the IUT.
-
- - Verification: The IP Tester will display each reply
- datagram as it arrives at the IP Tester. If their 12-byte
- data fields are displayed in the order "ident = 223", "ident
- = 222", "ident = 221", "ident = 220", "ident = 219", "ident
- = 218", "ident = 217", "ident = 216", the test was highly
- successful. If displayed by order of their "ident" number,
- the test was marginally successful.
-
- The summation of the absolute value of the "ident" value of
- the Nth datagram sent minus the "ident" value of the Nth
- datagram received in reply by the IP Tester may be used to
- derive a figure of merit. The best figure is 32 and the
- worst figure is 0.
-
- Success: Display of reply datagrams.
- Failure: Any response other than the display of the reply
- datagrams in any order.
-
- Scenario File PrecMxdTest: "Mixed Precedence Test" datagrams
-
- NOTICE: This test scenario has been dropped because it's
- useless.
-
- Scenario File PrecTopTest: "Top-down Precedence Test" datagrams
-
- WARNING: This test depends on the IMPs to deliver a successive
- datagram with a lower precedence than a preceding datagram after
- the preceding datagram. A failure of the network to deliver the
- datagrams as indicated is primarily a reflection of the quality the
- network and not of the IUT. The IUT is only required to accept all
- eight datagrams and send eight reply datagrams. As of the date this
- was written, this test has never failed to deliver the indicated
- results.
-
- 208 precedence 7
-
- 209 precedence 6
-
- 210 precedence 5
-
- 211 precedence 4
-
- 212 precedence 3
-
- 213 precedence 2
-
- 214 precedence 1
-
- 215 precedence 0
-
-
-
- Test 208 precedence 7
-
- - Can the IUT send a datagram with precedence 7?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram at precedence 7 to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 208 prec = 7 " in its
- 21-byte data field. The display must contain the string
- "V4HL5P7" to indicate that the datagram was sent at
- precedence 7.
-
- Success: Display of reply datagram.
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 209 precedence 6
-
- - Can the IUT send a datagram with precedence 6?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram at precedence 6 to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 209 prec = 6 " in its
- 21-byte data field. The display must contain the string
- "V4HL5P6" to indicate that the datagram was sent at
- precedence 6.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 210 precedence 5
-
- - Can the IUT send a datagram with precedence 5?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram at precedence 5 to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 210 prec = 5 " in its
- 21-byte data field. The display must contain the string
- "V4HL5P5" to indicate that the datagram was sent at
- precedence 5.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 211 precedence 4
-
- - Can the IUT send a datagram with precedence 4?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram shouId be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram at precedence 4 to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 211 prec = 4 " in its
- 21-byte data field. The display must contain the string
- "V4HL5P4" to indicate that the datagram was sent at
- precedence 4.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 212 precedence 3
-
- - Can the IUT send a datagram with precedence 3?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram at precedence 3 to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 212 prec = 3 " in its
- 21-byte data field. The display must contain the string
- "V4HL5P3" to indicate that the datagram was sent at
- precedence 3.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 213 precedence 2
-
- - Can the IUT send a datagram with precedence 2?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram at precedence 2 to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 213 prec = 2 " in its
- 21-byte data field. The display must contain the string
- "V4HL5P2" to indicate that the datagram was sent at
- precedence 2.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 214 precedence 1
-
- - Can the IUT send a datagram with precedence 1?
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram at precedence 1 to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 214 prec = 1 " in its
- 21-byte data field. The display must contain the string
- "V4HL5P1" to indicate that the datagram was sent at
- precedence 1.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 215 precedence 0
-
- - Can the IUT send a datagram with precedence 0?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram at precedence 0 to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 215 prec = 0 " in its
- 21-byte data field. The display must contain the string
- "V4HL5PO" to indicate that the datagram was sent at
- precedence 0.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Scenario File ReasMustTest: "Basic Reassembly Test" datagrams
-
- 500 two fragments
-
- 501 three fragments
-
- 502 four fragments
-
- 503 four fragments with middle fragments out of order
-
- 504 four fragments in reverse order
-
- 505 set and restart reassembly timeout timer
-
- 506 set and properly check reassembly timeout timer
-
- 507 duplicated header fragment
- 508 duplicated middle fragment
-
- 509 duplicated tail fragment
-
- 510 missing header fragment
-
- 511 missing middle fragment
-
- 512 missing tail fragment
-
- 513-514 reassemble two datagrams at once
-
- 515-516 fragmented datagram with missing tail fragment +
- good fragmented datagram
-
- 517 identification separation
-
- 518 protocol separation
-
- 519 middle fragment only
-
- 520 reassemble a 576-byte datagram fragmented on 8-octet
- boundaries
-
- 521 reassemble a 576-byte datagram fragmented on 16-octet
- boundaries
-
- 522 reassemble a 576-byte datagram fragmented on 32-octet
- boundaries
-
- 523 reassemble a 576-byte datagram fragmented on 64-octet
- boundaries
-
- 524 reassemble a 576-byte datagram fragmented on 128-octet
- boundaries
-
- 525 reassemble a 576-byte datagram fragmented on 256-octet
- boundaries
-
-
-
- Test 500 two fragments
-
- - Can the IUT reassemble a datagram split into two fragments?
-
- --Action: Send a datagram split into two fragments to the IP
- Implementation Under Test. This datagram should be reassembled
- by the IUT and passed to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the lP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 500 " in its 12-byte
- data field.
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 501 three fragments
-
- - Can the IUT reassemble a datagram split into three fragments?
-
- - Action: Send a datagram split into three fragments to the
- IP Implementation Under Test. This datagram should be
- reassembled by the IUT and passed to its Remote Driver. The
- IUT's Remote Driver should request the IUT to send the reply
- datagram required by the IP Remote Driver Specification to the
- IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 501 reliab = 1 " in its
- 23 byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 502 four fragments
-
- - Can the IUT reassemble a datagram split into four fragments?
-
- - Action: Send a datagram split into four fragments to the IP
- Implementation Under Test. This datagram should be reassembled
- by the IUT and passed to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 502 datalen = 42 ident =
- 502 datal" in its 42-byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 503 four fragments with middle fragments out of order
-
- - Can the IUT reassemble fragments received out of order?
-
- - Action: Send a fragmented datagram to the IP Implementation
- Under Test with the second and third fragments out of order.
- This datagram should be reassembled by the IUT and passed to
- its Remote Driver. The IUT's Remote Driver should request the
- IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 503 datalen = 43 ident =
- 503 datale" in its 43-byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 504 four fragments in reverse order
-
- - Can the IUT reassemble fragments received out of order?
-
- - Action: Send a fragmented datagram to the IP Implementation
- Under Test with fragments in reverse order. This datagram
- should be reassembled by the IUT and passed to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 504 datalen = 44 ident =
- 504 datalen" in its 44-byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 505 set and restart reassembly timeout timer
-
- - Can the LUT manage its reassembly timeout timer?
-
- - Action: Send a fragmented datagram to the IP Implementation
- Under Test. The first fragment is sent with a time to live
- value of 70 seconds. The IP Test Controller will wait for 55
- seconds before sending the next fragment with a time to live
- of 60 seconds. Since the reassembly timer should be down to
- around 14 seconds, it should be restarted. The IP Test
- Controller will wait for 45 seconds before sending the final
- fragment. The datagram should then be reassembled by the IUT
- and passed to its Remote Driver. The IUT's Remote Driver
- should request the IUT to send the reply datagram required by
- the IP Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 505 datalen = 45 ident =
- 505 datalen " in its 45-byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
- Test 506 set and properly check reassembly timeout timer
-
- - Can the IUT manage its reassembly timeout timer?
-
- - Action: Send a fragmented datagram to the IP Implementa-
- tion Under Test. The first fragment is sent with a time to
- live value of 20 seconds. The IP Test Controller will wait for
- 6 seconds before sending the next fragment with a time to live
- of 2 seconds. Since the reassembly timer should be down to
- around 13 seconds, it should not be restarted. The IP Test
- Controller will wait for 3 seconds before sending the final
- fragment. The datagram should then be reassembled by the IUT
- and passed to its Remote Driver. The IUT's Remote Driver
- should request the IUT to send the reply datagram required by
- the IP Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 506 datalen = 46 ident =
- 506 datalen =" in its 46-byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 507 duplicated header fragment
-
- - Can the IUT handle a duplicated header fragment?
-
- - Action: Send a fragmented datagram to the IP Implementation
- Under Test whose header fragment has been duplicated. This
- datagram should be reassembled by the IUT and passed to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 507 datalen = 47 ident =
- 507 datalen = " in its 47-byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 508 duplicated middle fragment
-
- - Can the IUT handle a duplicated middle fragment?
-
- - Action: Send a fragmented datagram to the IP Implementation
- Under Test whose middle fragment has been duplicated. This
- datagram should be reassembled by the IUT and passed to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 508 datalen = 48 ident =
- 508 datalen = 4" in its 48-byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 509 duplicated tail fragment
-
- - Can the IUT handle a duplicated tail fragment?
-
- - Action: Send a fragmented datagram to the IP Implementa-
- tion Under Test whose tail fragment has been duplicated. Both
- tail fragments are delivered out of order. This datagram
- should be reassembled by the IUT and passed to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 509 datalen = 59 ident =
- 509 datalen = 59 ident = 5" in its 59-byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 510 missing header fragment
-
- - Can the IUT handle a missing header fragment?
-
- - Action: Send a fragmented datagram to the IP Implementation
- Under Test whose header fragment is missing. The IUT's
- reassembly timeout timer should expire. The IUT may send an
- ICMP reassembly timeout message to the IP Tester.
-
- - Verification: If there is an IP Tester datagram display,
- it must contain "ICMP TIME EXCEEDED id=00510 REAS".
-
- Success: Display of optional ICMP reassembly timeout
- message.
-
- NOTICE: If there is a display of an ICMP reassembly timeout
- message, the IUT does not conform to RFC792.
-
- Failure: Any response other than the display of the ICMP
- reassembly timeout message or nothing.
-
- Test 511 missing middle fragment
-
- - Can the IUT handle a missing middle fragment?
- - Action: Send a fragmented datagram to the IP Implementation
- Under Test whose middle fragment is missing. The IUT's
- reassembly timeout timer should expire. The IUT may send an
- ICMP reassembly timeout message to the IP Tester.
-
- - Verification: If there is an IP Tester datagram display,
- it must contain "ICMP TIME EXCEEDED id=00511 REAS".
-
- Success: Display of optional ICMP reassembly timeout
- message.
-
- Failure: Any response other than the display of the ICMP
- reassembly timeout message or nothing.
-
- Test 512 missing tail fragment
-
- - Can the IUT handle a missing tail fragment?
-
- - Action: Send a fragmented datagram to the IP Implementation
- Under Test whose tail fragment is missing. The IUT's
- reassembly timeout timer should expire. The IUT may send an
- ICMP reassembly timeout message to the IP Tester.
-
- - Verification: If there is an IP Tester datagram display,
- it must contain "ICMP TIME EXCEEDED id=00512 REAS".
-
- Success: Display of optional ICMP reassembly timeout
- message.
-
- Failure: Any response other than the display of the ICMP
- reassembly timeout message or nothing.
-
- Test 513 reassemble two datagrams at once
-
- - Can the IUT reassemble two datagrams at once?
-
- - Action: Send two fragmented datagrams to the IP
- Implementation Under Test. Each fragment of the first datagram
- is followed by a fragment from the second datagram. Each
- datagram should be reassembled by the IUT and passed to its
- Remote Driver. The IUT's Remote Driver should request the IUT
- to send the reply datagrams required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the first reply
- datagram that must contain "ident = 513 datalen = 43 ident =
- 513 datal" in its 43-byte data field. This should be
- followed by the IP Tester display the second reply datagram
- that must contain "ident = 514 datalen = 44 ident = 514
- datale" in its 44-byte data field.
-
- Success: Display of reply datagrams.
- Failure: Any response other than the display of the reply
- datagrams.
-
- Test 515 fragmented datagram with missing tail fragment +
- good fragmented datagram
-
- - Can the IUT handle two datagrams independently?
-
- - Action: Send a fragmented datagram to the IP Implementation
- Under Test whose tail fragment is missing. These are
- intermixed with a complete set of fragments for a second
- datagram also sent to the IUT. The second datagram should be
- reassembled and passed to the IUT's Remote Driver. The IUT's
- Remote Driver should request the IUT to send the reply
- datagram required by the IP Remote Driver Specification to the
- IP Tester. The IUT's reassembly timeout timer for the
- incomplete set of fragments should expire later. The IUT may
- send an ICMP reassembly timeout message to the IP Tester.
-
- - Verification: The IP Tester will display the first reply
- datagram that must contain "ident = 516 datalen = 46 ident =
- 516 datalen " in its 46-byte data field. This may be
- followed by an IP Tester datagram display containing "ICMP
- TIME EXCEEDED id=00515 REAS".
-
- Success: Display of reply datagram and optional ICMP
- reassembly timeout message.
-
- Failure: Any response other than the reply datagram and
- optional ICMP reassembly timeout message display.
-
- Test 517 identification separation
-
- - Can the IUT handle two datagrams independently?
-
- - Action: Send fragments to the IP Implementation Under Test
- that would be sufficient to reassembIe a datagram if their
- identification fields were identical. The IUT is required to
- treat these fragments as parts of two separate datagrams in
- accordance with section 9.4.1. The IUT's reassembly timeout
- timer for each reassembly should expire later. The IUT may
- send an ICMP reassembly timeout message to the IP Tester for
- each.
-
- - Verification: The IP Tester will display each ICMP
- reassembly timeout message that the IUT may send. They must
- contain "ICMP TIME EXCEEDED. id=00517 REAS" or "ICMP TIME
- EXCEEDED id=00001 REAS" and may appear in either order or
- alone. Neither may be duplicated.
-
- Success: Display of optional ICMP reassembly timeout
- message(s).
- Failure: Any response other than the optional ICMP
- reassembly timeout message(s).
-
- Test 518 protocol separation
-
- - Can the IUT handle two datagrams independently?
-
- - Action: Send fragments to the IP Implementation Under Test
- that would be sufficient to reassemble a datagram if their
- protocol fields were identical. The IUT is required to treat
- these fragments as parts of two separate datagrams in
- accordance with section 9.4.1. The IUT's reassembly timeout
- timer for each reassembly should expire later. The IUT may
- send an ICMP reassembly timeout message to the IP Tester for
- each.
-
- - Verification: The IP Tester will display each of the two
- ICMP reassembly timeout messages that the IUT may send. They
- must contain "ICMP TIME EXCEEDED id=00518 REAS".
-
- Success: Display of optional ICMP reassembly timeout
- message(s).
-
- NOTICE: If there is a display of two ICMP reassembly
- timeout messages, the IUT does not conform to RFC792.
-
- Failure: Any response other than the optional ICMP
- reassembly timeout message(s).
-
- Test 519 middle fragment only
-
- - Can the IUT handle missing header and tail fragments?
-
- - Action: Send a fragment from the middle of a datagram to
- the IP Implementation Under Test. The IUT's reassembly timeout
- timer should expire. The IUT may send an ICMP reassembly
- timeout message to the IP Tester.
-
- - Verification: If there is an IP Tester datagram display,
- it must contain "ICMP TIME EXCEEDED id=00519 REAS".
-
- Success: Display of optional ICMP reassembly timeout
- message.
-
- NOTICE: If there is a display of an ICMP reassembly timeout
- message, the IUT does not conform to RFC792.
-
- Failure: Any response other than the display of the ICMP
- reassembly timeout message or nothing.
-
- Test 520 reassemble a 576-byte datagram fragmented on 8-octet
- boundaries
-
- - Can the IUT reassemble a fragmented 576 byte datagram?
- Test 520 reassemble a 576-byte datagram fragmented on 8-octet
- boundaries
-
- - Can the IUT reassemble a fragmented 576 byte datagram?
-
- - Action: Send a 576-byte datagram fragmented on 8-octet
- boundaries to the IP Implementation Under Test. This datagram
- should be reassembled by the IUT and passed to its Remote
- Driver. The IUT's Remote Driver should then request the IUT to
- send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 520 datalen = 48 ident =
- 520 datalen = 4" in its 48-byte data field.
-
- . Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 521 reassemble a 576-byte datagram fragmented on 16-octet
- boundaries
-
- - Can the IUT reassemble a fragmented 576-byte datagram?
-
- - Action: Send a 576-byte datagram fragmented on 16-octet
- boundaries to the IP Implementation Under Test. This datagram
- should be reassembled by the IUT and passed to its Remote
- Driver. The IUT's Remote Driver should then request the IUT to
- send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 521 datalen = 48 ident =
- 521 datalen = 4" in its 48-byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 522 reassemble a 576-byte datagram fragmented on 32-octet
- boundaries
-
- - Can the IUT reassemble a fragmented 576-byte datagram?
-
- - Action: Send a 576-byte datagram fragmented on 32-octet
- boundaries to the IP Implementation Under Test. This datagram
- should be reassembled by the IUT and passed to its Remote
- Driver. The IUT's Remote Driver should then request the IUT to
- send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 522 datalen = 48 ident
- 522 datalen = 4" in its 48-byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 523 reassemble a 576-byte datagram fragmented on 64-octet
- boundaries
-
- - Can the IUT reassemble a fragmented 576-byte datagram?
-
- - Action: Send a 576-byte datagram fragmented on 64-octet
- boundaries to the IP Implementation Under Test. This datagram
- should be reassembled by the IUT and passed to its Remote
- Driver. The IUT's Remote Driver should then request the IUT to
- send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 523 datalen = 48 ident =
- 523 datalen = 4" in its 48-byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 524 reassemble a 576-byte datagram fragmented on 128-octet
- boundaries
-
- - Can the IUT reassemble a fragmented 576-byte datagram?
-
- - Action: Send a 576-byte datagram fragmented on 128-octet
- boundaries to the IP Implementation Under Test. This datagram
- should be reassembled by the IUT and passed to its Remote
- Driver. The IUT's Remote Driver should then request the IUT to
- send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 524 datalen = 48 ident =
- 524 datalen = 4" in its 48-byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 525 reassemble a 576-byte datagram fragmented on 256-octet
- boundaries
- ident = 1024 datalen = 1004 ident = 1024 datalen = 1004
- ident = 1024 datalen = 1004 ident = 1024 datalen = 1004
- ident = 1024 datalen = 1004 ident = 1024 datalen = 1004
- ident = 1024 datalen = 1004 ident = 1024 datalen = 1" in a
- 1004 byte data field
-
- or
-
- "ident = 1024 notimpl" in a 20-byte data field.
-
- The 1004-data byte reply datagram may arrive in fragments
- that will also be displayed.
-
- Success: Display of reply datagram or not implemented
- message.
-
- Failure: Any response other than the display of the reply
- datagram or not implemented message.
-
- Scenario File Send1144Test: "Send 1144-Byte Datagram Test"
-
- 1144 transmission of 1144-byte datagram
-
-
-
-
- Test 1144 transmission of 1144-byte datagram
-
- - Can the IUT send an 1144-byte datagram?
-
- - Action: Send datagram to the IP Implementation Under Test.
- The IUT should pass this datagram to its Remote Driver. The
- IUT's Remote Driver should then request the IUT to send the
- 1144-byte reply datagram required by the IP Remote Driver
- Specification to the IP Tester. If the IUT can't send it, it
- should inform its Remote Driver so the Remote Driver can
- request the IUT to send an IP Remote Driver not implemented
- message instead.
-
- - Verification: The IP Tester will display the reply
- datagram that may contain either:
-
- "ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- ident = 1144 datalen = 1124 ident = 1144 datalen = 1124
- iden" in a 1124 byte data field
-
- or
-
- "ident = 1144 notimpl" in a 20-byte data field.
-
- The 1124-data byte reply datagram may arrive in fragments
- that will also be displayed.
-
- Success: Display of reply datagram or not implemented
- message.
-
- Failure: Any response other than the display of the reply
- datagram or not implemented message.
-
- Scenario File Send576Test: "Send 576-Byte Datagram Test"
-
- 576 transmission of 576-byte datagram
-
-
-
- Test 576 transmission of 576-byte datagram
-
- - Can the IUT send an 576-byte datagram?
-
- - Action: Send datagram to the IP Implementation Under Test.
- The IUT should pass this datagram to its Remote Driver. The
- IUT's Remote Driver should then request the IUT to send the
- 576 byte reply datagram required by the IP Remote Driver
- Specification to the IP Tester. If the IUT can't send it, it
- should inform its Remote Driver so the Remote Driver can
- request the IUT to send an IP Remote Driver not implemented
- message instead.
-
- - Verification: The IP Tester will display the reply
- datagram that may contain either:
-
- "ident = 576 datalen = 556 ident = 576 datalen = 556
- ident = 576 datalen = 556 ident = 576 datalen = 556
- ident = 576 datalen = 556 ident = 576 datalen = 556
- ident = 576 datalen = 556 ident = 576 datalen = 556
- ident = 576 datalen = 556 ident = 576 datalen = 556
- ident = 576 datalen = 556 ident = 576 datalen = 556
- ident = 576 datalen = 556 ident = 576 datalen = 556
- ident = 576 datalen = 556 ident = 576 datalen = 556
- ident = 576 datalen = 556 ident = 576 datalen = 556
- ident = 576 datalen = 556 ident = 576 datalen = 556
- The 556-data byte reply datagram may arrive in fragments
- that will also be displayed.
-
- Success: Display of reply datagram or not implemented
- message.
-
- Failure: Any response other than the display of the reply
- datagram or not implemented message.
-
- Scenario File Send68Test: "Send 68-Byte Datagram Test"
-
- Test 68 transmission of 68-byte datagram
-
-
-
- Test 68 transmission of 68-byte datagram
-
- - Can the IUT send an 68-byte datagram?
-
- - Action: Send datagram to the IP Implementation Under Test.
- The IUT should pass this datagram to its Remote Driver. The
- IUT's Remote Driver should then request the lUT to send the
- 68-byte reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 68 datalen = 48 dontfrag
- = 1 ident = 68" in a 48-byte data field. The display must
- also contain "F00000" to indicate that the datagram wasn't
- fragmented.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Scenario File TOS BitBotTest: "Bottom-up Type of Service Test"
- datagrams
-
- 300 type of service bits clear
-
- 301 reliability bit set
-
- 302 throughput bit set
-
- 303 delay bit set
-
- 304 reliability + throughput bits set
-
- 305 reliability + delay bits set
-
- 306 throughput + delay bits set
-
- 307 reliability + throughput + delay bits set
- 304 reliability + throughput bits set
-
- 305 reliability + delay bits set
-
- 306 throughput + delay bits set
-
- 307 reliability + throughput + delay bits set
-
-
-
-
- Test 300 type of service bits clear
-
- - Can the IUT receive a datagram with its type of service
- bits clear?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with its type of service bits clear. This datagram should be
- passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 300 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 301 reliability bit set
-
- - Can the IUT receive a datagram with its reliability bit
- set?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with its reliability bit set. This datagram should be passed
- by the IUT to its Remote Driver. The IUT's Remote Driver
- should request the IUT to send the reply datagram required by
- the IP Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 301 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 302 throughput bit set
- - Can the IUT receive a datagram with its throughput bit set?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with its throughput bit set. This datagram should be passed by
-
- the IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply datagram
- that must contain "ident = 302 " in its 12-byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 303 delay bit set
-
- - Can the IUT receive a datagram with its delay bit set?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with its delay bit set. This datagram should be passed by the
- IUT to its Remote Driver. The IUT's Remote Driver should request
- the IUT to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply datagram
- that must contain "ident = 303 " in its 12-byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 304 reliability + throughput bits set
-
- - Can the IUT receive a datagram with its reliability and
- throughput bits set?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with its reliability and throughput bits set. This datagram
- should be passed by the IUT to its Remote Driver. The IUT's
- Remote Driver should request the IUT to send the reply data-
- gram required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply datagram
- that must contain "ident = 304 " in its 12-byte data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 305 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 306 throughput + delay bits set
-
- - Can the IUT receive a datagram with its throughput and
- delay bits set?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with its throughput and delay bits set. This datagram should
- be passed by the IUT to its Remote Driver. The IUT's Remote
- Driver should request the IUT to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 306 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 307 reliability + throughput + delay bits set
-
- - Can the IUT receive a datagram with its reliability,
- throughput, delay bits set?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with its reliability, throughput, and delay bits set. This
- datagram should be passed by the IUT to its Remote Driver. The
- IUT's Remote Driver should request the IUT to send the reply
- datagram required by the IP Remote Driver Specification to the
- IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 307 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
- Scenario File TOS BitMxdTest: "Mixed Type of Service Test"
- datagrams
-
- NOTICE: This test scenario has been dropped because it's
- useless.
-
- Scenario File TOS BitTopTest: "Top-Down Type of Service Test"
- datagrams
-
- 308 reliability + throughput + delay bits set
-
- 309 throughput + delay bits set
-
- 310 reliability + delay bits set
-
- 311 reliability + throughput bits set
-
- 312 delay bit set
-
- 313 throughput bit set
-
- 314 reliability bit set
-
- 315 type of service bits clear
-
-
-
- Test 308 reliability + throughput + delay bits set
-
- - Can the IUT send a datagram with its reliability,
- throughput, and delay bits set?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with its reliability, throughput, and delay
- bits set to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 308 reliab = 1 throu = 1
- delay = 1 " in its 43-byte data field. The display must
- contain the string "V4HL5PODTR" to indicate that the
- datagram was sent with its reliability, throughput, and
- delay bits set.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 309 throughput + delay bits set
-
- - Can the IUT send a datagram with its throughput and delay
- bits set?
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with its throughput and delay bits set to
- the IP Tester.
-
- - Verification: The IP Tester will display the reply datagram
- that must contain "ident = 309 throu = 1 delay = 1 " in its
- 32 byte data field. The display must contain the string
- "V4HL5PODT " to indicate that the datagram was sent with its
- throughput and delay bits set.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 310 reliability + delay bits set
-
- - Can the IUT send a datagram with its reliability and delay
- bits set?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with its reliability and delay bits set to
- the IP Tester.
-
- - Verification: The IP Tester will display the reply datagram
- that must contain "ident = 310 reliab = 1 delay = 1 " in its
- 33 byte data field. The display must contain the string
- "V4HL5POD R" to indicate that the datagram was sent with its
- reliability and delay bits set.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 311 reliability + throughput bits set
-
- - Can the IUT send a datagram with its reliability and
- throughput bits set?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with its reliability and throughput bits
- set to the IP Tester.
-
- - Verification: The IP Tester will display the reply datagram
- that must contain "ident = 311 reliab = 1 throu = 1 " in its
- 33-byte data field. The display must contain the string
- "V4HL5PO TR" to indicate that the datagram was sent with its
- reliability and throughput bits set.
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 312 delay bit set
-
- - Can the IUT send a datagram with its delay bit set?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with its delay bit set to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 312 delay = 1 " in its
- 22-byte data field. The display must contain the string
- "V4HL5POD " to indicate that the datagram was sent with its
- delay bit set.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 313 throughput bit set
-
- - Can the IUT send a datagram with its throughput bit set?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with its throughput bit set to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 313 throu = 1 " in its
- 22-byte data field. The display must contain the string
- "V4HL5PO T " to indicate that the datagram was sent with its
- throughput bit set.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 314 reliability bit set
-
- - Can the IUT send a datagram with its reliability bit set?
-
- -- Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with its reliability bit set to the IP
- Tester.
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 314 reliab = 1 " in its
- 23-byte data field. The display must contain the string
- "V4HL5PO R" to indicate that the datagram was sent with its
- reliability bit set.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 315 type of service bits clear
-
- - Can the IUT send a datagram with its type of service bits
- clear?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with its type of service bits clear to the
- IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 315 " in its 12-byte
- data field. The display must contain the string "V4HL5PO" to
- indicate that the datagram was sent with its type of service
- bits clear.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Scenario File TOS GateTest: "Gateway Type of Service Test"
- datagrams
-
- 400 low delay + high reliability
-
- 401 low delay + high throughput
-
- 402 maximum precedence + high reliability
-
- 403 maximum precedence + high reliability + low delay
-
- 404 maximum precedence + high throughput
-
- 405 maximum precedence + high throughput + high reliability
-
- 406 low precedence + low delay
-
- 407 low precedence + low delay + high reliability
-
- 408 very low precedence + low delay + high reliability +
- high throughput
- 409 high precedence + low delay + high reliability +
- high throughput
-
- 410 maximum precedence + low delay + high reliability +
- high throughput
-
-
-
-
- Test 400 low delay + high reliability
-
- - Can the IUT forward a datagram which should be sent with low
- delay and high reliability?
-
- - Action: Send a datagram to the gateway IUT that should be
- forwarded to the host IP with low delay and high reliability.
- It should then be passed by the host IP to its Remote Driver.
- The host IP's Remote Driver should request the host IP to
- send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 400" in its data
- field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 401 low delay + high throughput
-
- - Can the IUT forward a datagram which should be sent with low
- delay and high throughput?
-
- - Action: Send a datagram to the gateway IUT that should be
- forwarded to the host IP with low delay and high throughput.
- It should then be passed by the host IP to its Remote Driver.
- The host IP's Remote Driver should request the host IP to
- send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 401 " in its data
- field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 402 maximum precedence + high reliability
- - Can the IUT forward a datagram which should be sent with
- maximum precedence and high reliability?
-
- - Action: Send a datagram to the gateway IUT that should be
- forwarded to the host IP with maximum precedence and high
- reliability. It should then be passed by the host IP to its
- Remote Driver. The host IP's Remote Driver should request the
- host IP to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 402 " in its data
- field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 403 maximum precedence + high reliability + low delay
-
- - Can the IUT forward a datagram which should be sent with
- maximum precedence, high reliability, and low delay?
-
- - Action: Send a datagram to the gateway IUT that should be
- forwarded to the host IP with maximum precedence, high
- reliability, and low delay. It should then be passed by the
- host IP to its Remote Driver. The host IP's Remote Driver
- should request the host IP to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 403 " in its data
- field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 404 maximum precedence + high throughput
-
- - Can the IUT forward a datagram which should be sent with
- maximum precedence and high throughput?
-
- - Action: Send a datagram to the gateway IUT that should be
- forwarded to the host IP with maximum precedence and high
- throughput. It should then be passed by the host IP to its
- Remote Driver. The host IP's Remote Driver should request the
- host IP to send the reply datagram required by the IP Remote
- Driver Specification to the IP Tester.
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 404 " in its data
- field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 405 maximum precedence + high throughput + high reliability
-
- - Can the IUT forward a datagram which should be sent with
- maximum precedence, high throughput, and high reliability?
-
- - Action: Send a datagram to the gateway IUT that should be
- forwarded to the host IP with maximum precedence, high
- throughput, and high reliability. It should then be passed by
- the host IP to its Remote Driver. The host IP's Remote Driver
- should request the host IP to send the reply datagram
- required by the IP Remote Driver Specification to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 405 " in its data
- field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 406 low precedence + low delay
-
- - Can the IUT forward a datagram which should be sent with low
- precedence and low delay?
-
- - Action: Send a datagram to the gateway IUT that should be
- forwarded to the host IP with low precedence and low delay.
- It should then be passed by the host IP to its Remote Driver.
- The host IP's Remote Driver should request the host IP to
- send the reply datagram required by the IP Remote Driver
- Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 406 " in its data
- field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 407 low precedence + low delay + high reliability
- - Can the IUT forward a datagram which should be sent with low
- precedence, low delay, and high reliability?
-
- - Action: Send a datagram to the gateway IUT that should be
- forwarded to the host IP with low precedence, low delay, and
- high reliability. It should then be passed by the host IP to
- its Remote Driver. The host IP's Remote Driver should request
- the host IP to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 407 " in its data
- field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 408 very low precedence + low delay + high reliability +
- high throughput
-
- - Can the IUT forward a datagram which should be sent with
- very low precedence, low delay, high reliability, and high
- throughput?
-
- - Action: Send a datagram to the gateway IUT that should be
- forwarded to the host IP with very low precedence, low delay,
- high reliability, and high throughput. It should then be
- passed by the host IP to its Remote Driver. The host IP's
- Remote Driver should request the host IP to send the reply
- datagram required by the IP Remote Driver Specification to
- the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 408 " in its data
- field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 409 high precedence + low delay + high reliability +
- high throughput
-
- - Can the IUT forward a datagram which should be sent with
- high precedence, low delay, high reliability, and high
- throughput?
-
- - Action: Send a datagram to the gateway IUT that should be
- forwarded to the host IP with high precedence, low delay,
- high reliability, and high throughput. It should then be
- passed by the host IP to its Remote Driver. The host IP's
- Remote Driver should request the host IP to send the reply
- datagram required by the IP Remote Driver Specification to
- the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 409 " in its data
- field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 410 maximum precedence + low delay + high reliability +
- high throughput
-
- - Can the IUT forward a datagram which should be sent with
- maximum precedence, low delay, high reliability, and high
- throughput?
-
- - Action: Send a datagram to the gateway IUT that should be
- forwarded to the host IP with maximum precedence, low delay,
- high reliability, and high throughput. It should then be
- passed by the host IP to its Remote Driver. The host IP's
- Remote Driver should request the host IP to send the reply
- datagram required by the IP Remote Driver Specification to
- the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 410 " in its data
- field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Scenario File TTLBdDotTest: "Bad Time to Live Bottom-up Test"
- datagrams
-
- 607 time to live of 0
-
- 608 time to live of 1
-
-
-
-
- Test 607 time to live of 0
-
- - Can the IUT detect a bad time to live ?
-
- - Action: Send a datagram from the IP Tester to the IP
- Implementation Under Test whose sole defect is a time to
- live that is illegally small. This error should be caught by
- the IUT. The IUT may send an IGMP time to live exceeded
- message to the IP Tester.
- - Verification: If there is a response datagram displayed by
- the IP Tester, its display should contain the string "ICMP
- TIME EXCEEDED ID=00607 TTLE". The string "ident = 607 "
- should not appear in the display of the response datagram
- because this would indicate that the datagram was passed by
- the IUT to its Remote Driver.
-
- Success: An ICMP Parameter Problem message displayed by the
- IP Tester. The total lack of an IP Tester response datagram
- display is also an acceptable response.
-
- NOTICE: The IUT does not appear to receive datagrams sent
- with a time to live of 0. Decause the author doesn't have a
- line analyser, it is not clear what the problem is. The
- author "remembers" that the test used to function.
-
- Failure: A response datagram whose IP Tester display contains
- the string "ident = 607 ".
-
- Test 608 time to live of 1
-
- - Can the IUT detect a bad time to live ?
-
- - Action: Send a datagram from the IP Tester to the IP
- Implementation Under Test whose sole defect is a time to
- live that is too small. This error should bs caught by the
- IUT. The IUT may send an ICMP time to live exceeded message
- to the IP Tester.
-
- - Verification: If there is a response datagram displayed by
- the IP Tester, its display should contain the string "ICMP
- TIME EXCEEDED ID=00608 TTLE". The string "ident = 608
- should not appear in the display of the response datagram
- because this would indicate that the datagram was passed by
- the IUT to its Remote Driver.
-
- Success: An ICMP Parameter Problem message displayed by the
- IP Tester. The total lack of an IP Tester response datagram
- display is also an acceptable response.
-
- Failure: A response datagram whose IP Tester display contains
- the string "ident = 608
-
- Scenario File TTLDdTopTest: "Bad Time to Live Top-down Test"
- datagrams
-
- 616 time to live of 1
-
- 617 time to live of 0
-
-
-
- Test 616 time to live of 1
- - Can the IUT send a datagram with time to live of 1?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with a time to live of 1 to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 616 ipttl = 1 " in its
- 22 byte data field. The IP Tester will also display the
- string "bad time to live" to indicate that a MIL=STD-1777 IP
- will not accept the datagram.
-
- Success: Display of reply datagram and the "bad time to
- live" string.
-
- Failure: Any response other than the display of the reply
- datagram and "bad time to live" string.
-
- Test 617 time to live of 0
-
- - Can the IUT send a datagram with time to live of 0?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram shouId be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with a time to live of 0 to the IP Tester.
- The IUT is required to inform its Remote Driver that the
- request is invalid. The Remote Driver should then request the
- IUT to send an IP Remote Driver Specification error message to
- the IP Tester.
-
- - Verification: The IP Tester will display the error message
- that must contain "ident = 617 error" in its 17-byte data
- field.
-
- Success: Display of error message datagram.
-
- Failure: Any response other than the display of the error
- message datagram.
-
- Scenario File TTLGdBotTest: "Good Time to Live Bottom-up Test"
- datagrams
-
- 600 time to live 255
-
- 601 time to live 129
-
- 602 time to live 128
-
- 603 time to live 127
-
- 604 time to live 20
- 605 time to live 85
-
- 606 time to live 170
-
-
-
-
- Test 600 time to live 255
-
- - Can the IUT receive a datagram with a time to live of 255?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a time to live of 255. This datagram should be passed by
- the IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 600 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 601 time to live 129
-
- - Can the IUT receive a datagram with a time to live of 129?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a time to live of 129. This datagram should be passed by
- the IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 601 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 602 time to live 128
-
- - Can the IUT receive a datagram with a time to live of 128?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a time to live of 128. This datagram should be passed by
- the IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 602 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 603 time to live 127
-
- - Can the IUT receive a datagram with a time to live of 127?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a time to live of 127. This datagram should be passed by
- the IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 603 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 604 time to live 20
-
- - Can the IUT receive a datagram with a time to live of 20?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a time to live of 20. This datagram should be passed by
- the IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 604 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 605 time to live 85
-
- - Can the IUT receive a datagram with a time to live of 85?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a time to live of 85. This datagram should be passed by
- the IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 605 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 606 time to live 170
-
- - Can the IUT receive a datagram with a time to live of 170?
-
- - Action: Send a datagram to the IP Implementation Under Test
- with a time to live of 170. This datagram should be passed by
- the IUT to its Remote Driver. The IUT's Remote Driver should
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 606 " in its 12-byte
- data field.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Scenario File TTLGdTopTest: "Good Time to Live Top-down Test"
- datagrams
-
- 609 time to live 255:
-
- 610 time to live 129
-
- 611 time to live 128
-
- 612 time to live 127
-
- 613 time to live 20
-
- 614 time to live 85
-
- 615 time to live 170
-
-
-
- Test 609 time to live 255
-
- - Can the IUT send a datagram with a time to live of 255?
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with a time to live of 255 to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 609 ipttl = 255 " in its
- 24-byte data field. The display must contain the string
- "TTL255" to indicate that the datagram was sent with a time
- to live of 255.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 610 time to live 129
-
- - Can the IUT send a datagram with a time to live of 129?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with a time to live of 129 to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 610 ipttl = 129 " in its
- 24 byte data field. The display must contain the string
- "TTL129" to indicate that the datagram was sent with a time
- to live of 129.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 611 time to live 128
-
- - Can the IUT send a datagram with a time to live of 128?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with a time to live of 128 to the IP
- Tester.
-
- -- Verification: The IP Tester will display the reply
- datagram that must contain "ident = 611 ipttl = 128 " in its
- 24-byte data field. The display must contain the string
- "TTL128" to indicate that the datagram was sent with a time
- to live of 128.
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 612 time to live 127
-
- - Can the IUT send a datagram with a time to live of 127?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with a time to live of 127 to the IP
- Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 612 ipttl = 127 " in its
- 24-byte data field. The display must contain the string
- "TTL127" to indicate that the datagram was sent with a time
- to live of 127.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 613 time to live 20
-
- - Can the IUT send a datagram with a time to live of 20?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with a time to live of 20 to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 613 ipttl = 20 " in its
- 23-byte data field. The display must contain the string
- "TTL020" to indicate that the datagram was sent with a time
- to live of 20.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 614 time to live 85
-
- - Can the IUT send a datagram with a time to live of 85?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with a time to live of 85 to the IP Tester.
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 614 ipttl = 85 " in its
- 23-byte data field. The display must contain the string
- "TTL085" to indicate that the datagram was sent with a time
- to live of 85.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Test 615 time to live 170
-
- - Can the IUT send a datagram with a time to live of 170?
-
- - Action: Send a datagram to the IP Implementation Under
- Test. This datagram should be passed by the IUT to its Remote
- Driver. The IUT's Remote Driver should request the IUT to send
- the reply datagram with a time to live of 170 to the IP
- Tester.
-
- -- Verification: The IP Tester will display the reply
- datagram that must contain "ident = 615 ipttl = 170 " in its
- 24-byte data field. The display must contain the string
- "TTL170" to indicate that the datagram was sent with a time
- to live of 170.
-
- Success: Display of reply datagram.
-
- Failure: Any response other than the display of the reply
- datagram.
-
- Scenario File Whole576Test: "Accept 576-Byte Datagram Test"
-
- 576 accept 576-byte datagram
-
-
-
- Test 576 accept 576-byte datagram
-
- - Can the IUT accept a 576 byte datagram?
-
- - Action: Send an unfragmented 576-byte datagram to the IP
- Implementation Under Test. The IUT should pass this datagram
- to its Remote Driver. The IUT's Remote Driver should then
- request the IUT to send the reply datagram required by the IP
- Remote Driver Specification to the IP Tester.
-
- - Verification: The IP Tester will display the reply
- datagram that must contain "ident = 576 datalen = 048
- datalen = 048 datalen " in a 48-byte data field.
-
- Success: Display of reply datagram.
- Failure: Any response other than the display of the reply
- datagram.