home *** CD-ROM | disk | FTP | other *** search
/ Liren Large Software Subsidy 13 / 13.iso / p / p069 / 4.img / HELP5.LIF / 52.HLP < prev    next >
Encoding:
Text File  |  1992-03-16  |  5.5 KB  |  151 lines

  1. PATTERN allows you to store a part-independent file
  2. containing geometry, dimensions, notes, labels, and
  3. crosshatching. You can retrieve a pattern at any time and
  4. add it to the part that you are working on. Saving a part 
  5. as a pattern file allows you to recall and display it at 
  6. any angle, in any scale, and to any level. This capability
  7. is extremely useful when you are creating a layout.
  8.  
  9. Choose one of the following options:
  10.  
  11. CREATE - to store entities as a pattern by selecting the
  12. desired entity(ies) for the pattern file, using a 
  13. Selection Menu option.
  14.  
  15. Indicate a base position for your pattern, using a 
  16. Position Menu option. This base position is used for 
  17. placing the pattern in other parts.
  18.  
  19. Enter a valid filename and press <Enter>, or accept the
  20. default name by pressing <Enter>. If you enter the 
  21. filename of an existing pattern file, you are prompted 
  22. to indicate whether you want to replace the existing file. 
  23. Choose an option from the NO/YES menu. 
  24.  
  25. RETRIEV - to retrieve a previously saved pattern file.
  26.  
  27. Enter the name of an existing pattern file, without an
  28. extension, and press <Enter>. If you include an extension
  29. (e.g., .ptn), it is ignored.
  30.  
  31. Specify whether or not the pattern file entities are to be
  32. grouped. If you choose to group the entities, assign a
  33. group name and, if necessary, a subgroup number, and press
  34. <Enter>.
  35.  
  36. Set the level assignments for entities in the pattern file
  37. in one of the following ways:
  38.  
  39. - by assigning all entities in the pattern file to the
  40. current active level when retrieved (CUR-LEV).
  41.  
  42. - by retaining the level assignment that each entity in 
  43. the pattern file had when the pattern file was created 
  44. (ENT-LEV).
  45.  
  46. - by assigning all entities in the pattern file to a 
  47. specified level (KEY-IN).
  48.  
  49. Enter a new level number for the pattern file entities.
  50. Enter the desired level number (1-256) and press <Enter>,
  51. or just press <Enter> to assign the entities to the 
  52. current active level.
  53.  
  54.  
  55. - by calculating a new level number for each entity in
  56. the pattern file by adding a user-specified integer to 
  57. each entity's current level number (OFFSET).
  58.  
  59. Enter a positive or negative integer for the desired 
  60. offset factor and press <Enter>, or just press <Enter> to
  61. retain the level assignments that were in effect when the 
  62. pattern file was created.
  63.  
  64. If the offset calculation results in an invalid level
  65. number (i.e., less than 1, greater than 256), you are
  66. prompted to press <Enter> and to enter a new offset
  67. factor.
  68.  
  69. With the DETAIL, SET, AUTO UP switch set to YES, the scale
  70. factor is applied to all entities in the pattern file
  71. except the displayed and actual values of angular
  72. dimensions, and the displayed values of manually entered
  73. dimensions.
  74.  
  75. Enter a scale factor for the pattern file and press
  76. <Enter>. To accept the default value in parentheses, press
  77. <Enter>.
  78.  
  79. The pattern can be rotated by entering a new rotation
  80. angle. Positive angle values move in a counter-clockwise
  81. direction. Negative angle values move clockwise. Enter a
  82. rotation angle and press <Enter>, or accept the current
  83. default by pressing <Enter>.
  84.  
  85. Locate a base position for the pattern within the current
  86. part by selecting an option from a Position Menu option.
  87.  
  88. The pattern is displayed in the current part file, at the
  89. specified scale and rotation angle.
  90.  
  91.  
  92. LIST/RTV (list/retrieve) - to list, select, and retrieve
  93. pattern files from a designated directory.
  94.  
  95. Enter the pathname for the pattern file directory, and
  96. press <Enter>. The default path in parentheses is the
  97. pattern file directory assigned in the CONFIG program. To
  98. accept the default directory, press <Enter>.
  99.  
  100. A listing of all pattern filenames in the designated
  101. directory is displayed on the screen. If you selected a
  102. VERBOSE filename listing (FILES, LIST FMT, VERBOSE),
  103. detailed display of information is displayed.
  104.  
  105. Choose the desired filename.
  106.  
  107. Choose from the NO/YES menu to specify whether or not the
  108. pattern file entities are to be grouped. If you choose YES
  109. to group the entities, you are then prompted to assign a
  110. group name and, if necessary, a subgroup number, and press
  111. <Enter>.
  112.  
  113. Set the level assignments for entities in the pattern file
  114. in one of the following ways:
  115.  
  116. - by assigning all entities in the pattern file a to the
  117. current active level when retrieved (CUR-LEV).
  118.  
  119. - by retaining the level assignment that each entity
  120. in the pattern file had when the pattern file was created.
  121. (ENT-LEV)
  122.  
  123. - by assigning all entities in the pattern file to a
  124. user-specified level. (KEY-IN)
  125.  
  126. - by calculating a new level number for each entity in
  127. the pattern file by adding a user-specified integer to 
  128. each entity's current level number.(OFFSET)
  129.  
  130. With the DETAIL, SET, AUTO UP switch set to YES, the scale
  131. factor is applied to all entities in the pattern file
  132. except the displayed and actual values of angular
  133. dimensions, and the displayed values of manually entered
  134. dimensions.
  135.  
  136. Enter a scale factor for the pattern file and press 
  137. <Enter>. To accept the default value in parentheses, press 
  138. <Enter>. 
  139.  
  140. The pattern can be rotated by entering a new rotation 
  141. angle. Positive angle values move in a counter-clockwise 
  142. direction. Negative angle values move clockwise. Enter a 
  143. value for the rotation angle and press <Enter>, or accept 
  144. the default value by pressing <Enter>.
  145.  
  146. Locate a base position for the pattern within the current
  147. part by selecting an option from a Position Menu option.