home *** CD-ROM | disk | FTP | other *** search
- WREPL Menu: (MWALS) MWEDT
- ===============================================================================
- Replaces multi-layer walls with other multi-layer walls.
-
- 1. (CHAR) option: i - single wall, s - selection group, a - all
- 2.* (CHAR) replace: c-by current wall, w-indicated wall, n-name, <ENT>-lib.
- for all options of prompt 1 if `w' is selected (in prompt 2):
- 3.* (IND) indicate sample wall
- 4.* (Y/N) confirm choice
- for all options of prompt 1 if `n' is selected (in prompt 2):
- 3.* (CHAR) name of wall (1-8 char., ln-xxxxx)
- if `i' is selected in prompt 1:
- 5.* (IND) indicate wall to be replaced
- 6.* (Y/N) confirm choice
- if there are 3D wall solids:
- 7.* (Y/N) keep 3D display? <y>
- for all options:
- 8.* (Y/N) keep the result ?
-
- Description
- This command replaces a single or group of multi-layer wall(s) with
- another multi-layer wall.
-
- Specify whether you want to replace a single wall, a selected group
- of walls, or all the walls. Select a replacement option for the replacing
- wall; use the current wall, indicate a sample wall, use a wall name
- or select a wall from the graphic library.
-
- If you choose to indicate the replacing wall, indicate and confirm it.
-
- If you choose for the replacing wall to be specified by its name,
- specify its name in the proper format, i.e., ln-xxxxx,
-
- where: l is the letter `l',
- n is the number of layers the wall contains,
- - is a hyphen, and
- xxxxx is the characters of the wall name (max. 5).
- For example: l3-20cm.
-
- If you choose to select the replacing wall from the graphic library,
- the library appears on the screen. Select a wall from the library.
-
- If you are replacing a single wall, indicate and confirm the wall
- to be replaced. The indicated wall will be replaced.
-
- If you are replacing a selection group, all the walls that are selected
- will be replaced.
-
- If you are replacing all the walls, all the walls will be replaced.
-
- If there are 3D wall solids you are asked whether the 3D display is to be
- kept or not. You are then asked if you want to keep the result or cancel
- the change.
-
- The replacement will be executed using the alignment
- axis as the guide line for the replacing wall.
-
- The replacement of the opening combinations within
- the walls are carried out according to the following rules:
-
- Condition Replacement
-
- If the combination contains Combination with end
- library end conditions conditions of same names
- or as in original applied.
- if one or both end
-
- conditions are missing:
-
- If both end conditions Default combination
- are SYSTEM applied.
- or
- if there is no combination
- with matching end
- condition names:
-
- If one side is "open" The first combination
- (no end condition) and which has only one end
- the other side is the condition on the same side
- SYSTEM end condition: irrespective of its name
- will be applied.
-
- If no combination for the The opening from the
- new wall and opening general opening library is
- exists: applied together with the
- system end conditions.