home *** CD-ROM | disk | FTP | other *** search
- CJUN Menu: MWALS
- ==============================================================================
- Creates a junction between three or four multi-layer walls.
-
- 1. (CHAR) no. of walls involved (3-4) <3>
- 2. (IND) first "head" wall
- 3. (Y/N) confirm choice
- 4. (IND) second "head" wall
- 5. (Y/N) confirm choice
- if `3' is selected in prompt 1:
- 6. (CHAR) "leg" wall
- 7. (Y/N) confirm choice
- 8. (Y/N) solution acceptable ?
- if `4' is selected in prompt 1:
- 6. (CHAR) first "leg" wall
- 7. (Y/N) confirm choice
- 8. (CHAR) second "leg" wall
- 9. (Y/N) confirm choice
- 10. (NUM) solution: 1-change 1st leg, 2-change 2nd leg, 3-acceptable
-
- Description
- This command creates a junction between three or four multi-layer walls. The
- rules for joining are governed by the contents of the TRULES.ARC file as in
- the creation of T-junctions (see \tjun).
-
- The first two walls (which must be of the same type, symmetry and alignment),
- behave as "heads" of the T while the third (and fourth wall if applicable)
- behaves like the "leg" of T.
-
- Specify whether the number of walls involved is three or four. Indicate and
- confirm the first and second "head" of the wall.
-
- In the case of three walls (`3' selected in prompt 1), where the leg extends
- through both sides of the head walls, the side indicated will be the side to
- remain. Indicate and confirm the "leg" of the wall. The three walls will be
- joined. Confirm if the solution is acceptable.
-
- In the case of four walls (if `4' was selected in prompt 1), indicate and
- confirm the first "leg" of the wall. Indicate and confirm the second "leg" of
- the wall. This must be on the opposite side of the first wall. The walls
- will be joined. Confirm if the solution is acceptable or specify to change
- the solution between the "heads" and the first "leg" or the second "leg" of
- the wall.
-
- If one, two or all three walls do not meet, the system will stretch or shorten
- the walls so that they meet.
-
- If all the indicated walls are the same type, the wall indicated first will
- penetrate the last walls indicated.