- ; USRobotics Courier V.32
-
- ;================================================
- ; Last revision date: 07/13/93 (update this date
- ; each time you edit; it is also advisable to rename
- ; your edited file [use Save As, rather than Save
- ; option] to avoid later confusion and to keep the
- ; original .MDM file intact).
-
- ; NOTE: Refer to the file TEMPLATE.MDM (A Sample Modem
- ; Command File) for a description of modem command
- ; files and how they work. "A Sample Modem Command
- ; File" is user selectable within the Lotus Notes
- ; Setup dialog "Modem Type" listbox in which you found
- ; this modem command file (see end of listings,
- ; beginning with a period) and is a printable ASCII
- ; text file (approximately 15 pages).
-
- ; Additional information may be obtained from either of
- ; the two so-called "generic" modem command files
- ; (alphabetically listed under letter G, designed for
- ; use with Notes Releases 2.x and 3.x, 9600 bps and
- ; 14400 bps maximum, respectively), each of which may
- ; first be tried as-is with unlisted modems, then edited
- ; if required (within the Notes edit box, or outside of
- ; Notes, with any text editor) according to the printed
- ; instructions within each file, and in compliance with
- ; the vendor's command set, result codes, DIP switch
- ; settings, and technical specifications as listed in
- ; the equipment's users manual.
-
- ; For the specific modem(s) listed under this heading:
- ;=====================================================
-
- ; Switch settings:
- ; Large switch: UP
- ; DIP switches: 1,2,4,6,7 = UP, all others DOWN
-
- [attributes]
-
- MODELS=USRobotics Courier V.32
- DEFAULT SPEED=38400
- MAXIMUM SPEED=38400
- NULL MODEM=0
-
- [commands]
-
- ESCAPE=+++
- ATTENTION=ATE0V1
- HANGUP=ATH0
- SETUP=AT&F
- SETUP=ATE0&A2B0&N0S10=15&B1
- SETUP=ATV1Q0S0=0S7=60X4
- RTS/CTS ENABLED=AT&H1&R2&K2
- RTS/CTS IGNORED=AT&H0&R1&K0
- VOLUME OFF=ATM0
- VOLUME LOW=ATM1
- VOLUME MEDIUM=ATM1
- VOLUME HIGH=ATM1
- ANSWER=ATA
- MANUAL DIAL=ATX3S9=1D,
- AUTO DIAL SETUP=ATS9=6
- AUTO PULSE DIAL=ATDP
- AUTO TONE DIAL=ATDT
- AUTO DIAL SUFFIX=,
-
- [responses]
-
- OK=OK
-
- RING=RING
-
- BUSY=BUSY
-
- NO DIALTONE=NO DIAL TONE
-
- NO ANSWER=NO ANSWER
-
- NO CARRIER=NO CARRIER
-
- ERROR=ERROR
-
- CONNECT, 38400,9600=CONNECT 9600
- CONNECT, 38400,9600=CONNECT 9600/ARQ
- CONNECT, 38400,9600=CONNECT 9600/V32
- CONNECT, 38400,9600=CONNECT 9600/ARQ/V32
-
- CONNECT, 38400,4800=CONNECT 4800
- CONNECT, 38400,4800=CONNECT 4800/ARQ
- CONNECT, 38400,4800=CONNECT 4800/V32
- CONNECT, 38400,4800=CONNECT 4800/ARQ/V32
-
- CONNECT, 38400,2400=CONNECT 2400
- CONNECT, 38400,2400=CONNECT 2400/ARQ
-
- CONNECT, 38400,1200=CONNECT 1200
- CONNECT, 38400,1200=CONNECT 1200/ARQ
-
-