home *** CD-ROM | disk | FTP | other *** search
-
- Addendum to BinkleyTerm Documentation
-
- Changes and Additions
- for BinkleyTerm Version 2.40
-
- Copyright (C) 1990 Bit Bucket Software, Co.
-
-
- INTRODUCTION
-
- Rather than update the BinkleyTerm documentation as we have done
- in the past, we are issuing this addendum file. It is important
- that you read this file thoroughly, as some of the information
- herein will supersede what is shown in the manual itself.
-
- By issuing this addendum, the printed versions of the BinkleyTerm
- manual now in circulation (and still available from Bit Bucket
- Software) will continue to be current (except for this addendum).
- The printed manuals were produced at great expense, and it has
- taken us a great deal of time to recoup our expenses. We hope to
- produce a printed manual again in the future, but for this
- release, the BinkleyTerm Version 2.30 docs (printed or otherwise)
- will remain current with this addendum.
-
- The mailing address for Bit Bucket Software has changed. If you
- wish to get ahold of us by mail for any reason, our address is:
-
- Bit Bucket Software, Co.
- P. O. Box 460398
- Aurora, CO 80046
-
- Please - do not write for technical support. Support is provided
- EXCLUSIVELY through the international BINKLEY EchoMail
- conference. When sending correspondence for other reasons,
- please include a self-addressed stamped envelope for replies.
- (Those persons not in the United States should enclose an
- International Postal Reply Coupon.)
-
- PRINTED MANUALS
-
- As mentioned previously, printed BinkleyTerm manuals are still
- available. Pricing covers the cost of printing, processing your
- request, and mailing. The prices are as follows:
-
- Within the United States:
- $15.00 Manual Only
- $25.00 Manual and Disk
-
- Outside the United States:
- $25.00 USD Manual Only
- $35.00 USD Manual and Disk
-
- All manuals will be delivered via regular mail.
-
- ----------------------------------
- USER'S GUIDE CHANGES AND ADDITIONS
- ----------------------------------
-
- ---------
- SECTION 3 Operation as an Automated Electronic Mailer
- ---------
-
- Janus Mail Protocol
-
- BinkleyTerm now features an experimental mail transfer
- protocol called "Janus." It is a bi-directional, full-
- duplex protocol, and generally requires a full-duplex modem
- to work properly (USRobotics Courier HST modems, for
- example, are not full-duplex and cannot use Janus
- effectively). Under ideal conditions, Janus allows you to
- transfer mail simultaneously in both directions with Zmodem-
- like performance.
-
- Due to the depth of the subject, Janus is covered completely
- in its own section toward the end of the document.
-
- Domain Support
-
- BinkleyTerm now features support for "domain" addressing.
- Due to the depth of the subject, domain addressing is
- covered completely in its own section toward the end of this
- document.
-
- Assumptions
-
- BinkleyTerm supports zone, net and domain assumption. If
- you have more than one address and different zones, nets, or
- domains are designated in the configuration file, then
- BinkleyTerm will use whichever address is appropriate when
- transacting mail.
-
- For example, net assumption might work as follows. If I
- have two addresses - 104/36 (primary address) and 1052/1
- (secondary address) - and someone calls from net 1052, then
- my system will identify itself at 1052/1. In all other
- cases, my system will identify itself as 104/36 (since it's
- my primary address). The purpose is that your system will
- identify itself as the most appropriate address depending on
- the address of the calling system.
-
- File Requests
-
- BinkleyTerm will no longer place calls for a stand-alone
- .REQ file. In order for a call to be placed, a packet or
- file attach of the proper flavor must also exist. As
- always, a manual poll will also allow a call to be placed.
-
- More Connect Messages
-
- Support for the following connect messages has been added:
-
- CONNECT 75 (Giving 1200/75 bps)
- CONNECT 103 (Giving 300 bps)
- CONNECT 12 (Giving 1200 bps)
- CONNECT 212 (Giving 1200 bps)
-
- -------------------------------------
- REFERENCE GUIDE CHANGES AND ADDITIONS
- -------------------------------------
-
- ---------
- SECTION 1 Configuring BinkleyTerm
- ---------
-
- CONFIGURATION FILE
-
- Colors <brdr> <sett> <today> <pend> <act> <txfr> <rev> <popwin>
-
- Identical as documented in the manual, except the addition
- of two more parameters. The <rev> parameter designates the
- reverse video color used in the Pending Outbound window to
- mark the node you are calling. The <popwin> parameter
- designates the color of pop-up windows (such as those
- produced with the Alt-G and Alt-S commands in Unattended
- Mode).
-
- Flags <dir>
-
- The directory name specified is used by BinkleyTerm to create
- task identification files. The filename is TASK.# where # is
- the task number. These files can be used to determine if any
- given Binkley task is currently running. The file is created
- whenever Binkley has carrier present and a mail session is
- in progress.
-
- FTS-0001
-
- When used, this statement will force BinkleyTerm to use only
- base FidoNet protocol (FTS-0001), effectively enabling the
- equivalent of the following statements: NoWaZOO, NoResync,
- NoSLO and NoSEAlink. Used mostly for debugging and testing
- of FidoNet policy compliance; not for regular use.
-
- JanusBaud
- JanusOK
-
- Controls whether Janus bi-directional protocol will be used
- during WaZOO sessions. Please refer to the complete Janus
- explanation later in this document.
-
- KnownMaxBytes
-
- See 'MaxBytes' for information.
-
- LockBaud [<lock_rate>]
-
- Works the same as what is documented in the manual, except
- it now accepts an optional parameter. The <lock_rate>
- parameter tells BinkleyTerm what baud rate at which locking
- should occur. This is useful for modems that allow a
- floating baud rate to a certain speed, then are locked at
- higher connect rates.
- Most ROM revisions of the USRobotics Courier HST 14.4k model
- and the USRobotics Courier HST Dual Standard allow this type
- of operation by setting the modem for &B0 which floats the
- baud rate at 2400 bps or lower. Bit 7 (and perhaps Bit 6)
- of the S27 register also need to be set appropriately.
-
- TO LOCK AT 19200 AND FLOAT AT SLOW SPEEDS: Use the
- 'Baud 19200' and 'LockBaud 4800' statements in your
- configuration file, and set the modem for &B0 and S27=128.
-
- TO LOCK AT 38400 AND FLOAT AT SLOW SPEEDS: Use the
- 'Baud 38400' and 'LockBaud 4800' statements in your
- configuration file, and set the modem for &B0 and S27=192.
-
- MaxBytes
-
- Together with the 'ProtMaxBytes' and 'KnownMaxBytes'
- statements, you can control file requests by number of bytes
- sent. These three statements work in the same manner as the
- other file request limiting statements detailed in the
- documentation. NOTE: There is a response file "Type 6"
- response now, which indicates that the caller has exceeded
- the byte limits.
-
- NoResync
-
- When used, this statement will tell BinkleyTerm not to allow
- SEAlink Resync (an ability to restart failed SEAlink mail
- sessions). Used mostly for debugging purposes; not for
- regular use.
-
- NoSEAlink
-
- When used, this statement will tell BinkleyTerm not to allow
- SEAlink mail sessions at all, including SEAlink extensions
- to base FidoNet protocol (FTS-0007) and WaZOO/DietIFNA
- sessions.
-
- NoZedZap
-
- When used, this statement will tell BinkleyTerm not to allow
- ZedZap (Zmodem) transfers during a WaZOO session. It is
- primarily intended to force BinkleyTerm to use DietIFNA mode
- (SEAlink) during WaZOO sessions. Used mostly for debugging
- purposes; not for regular use.
-
- ProtMaxBytes
-
- See 'MaxBytes' for information.
-
- ScreenBlank [<method>]
-
- Identical in function to what is documented in the manual,
- but now accepts an optional parameter. The <method>
- parameter may be "Key" or "Call" and tells BinkleyTerm which
- method to use to "unblank" the display. "Key" tells it to
- unblank upon a keypress (and is the default); "Call" tells
- it to unblank when a call comes in or is placed.
-
- TaskNumber <number>
-
- This statement performs two functions for persons operating
- in multi-processing or multi-line environments (through a
- LAN or multi-tasker).
-
- First, it designates a task number for the BinkleyTerm that
- uses the configuration file that this statement appears
- inside of. The <number> parameter must be greater than zero
- (0).
-
- Second, it tells BinkleyTerm to operate in "multi-processor
- smart mode." If BinkleyTerm is transacting with a
- particular system, it will create a "xxxxyyyy.BSY" file for
- that node, named in the conventional packet form (xxxx = net
- number in hex, yyyy = node number in hex). This file can
- serve as a flag to other BinkleyTerm tasks, or to compatible
- mail processing packages so that other tasks or processors
- will not handle any mail for the particular node until the
- ".BSY" file is gone. Additionally, BinkleyTerm will not
- send files to any node for which there is a ".BSY" file.
-
- TermInit <modem_string>
-
- Identical in structure to the 'Init' statement, this
- statement provides a modem initialization string that
- BinkleyTerm will use in Terminal Mode. The string will be
- sent to the modem if BinkleyTerm is initialized in Terminal
- Mode, or when switched to Terminal Mode from Unattended
- Mode. The string will also be sent when an Alt-I command is
- issued in Terminal Mode. NOTE: The 'PreInit' statement, if
- designated, will NOT be used in conjunction with this
- initialization string.
-
- SCHEDULING EVENTS CHANGES AND ADDITIONS
-
- Event Exits
-
- Event exits E4-E9 can now be followed by a three character
- string. If that string is matched in the file extension of
- a received file, then the designated errorlevel exit will be
- taken. For example:
-
- E4=100,TIC (Received .TIC Files Cause Exit 100)
- E5=100,FLE (Received .FLE Files Cause Exit 100)
- E6=110,REQ (Received .REQ Files Cause Exit 110)
- E7=120,MO? (Received .MO? Files Cause Exit 120)
-
- The order of exit precedence is as follows:
-
- E3
- E4-E9
- E2
- AfterMail
-
- When more than one E4-E9 exit applies, the first one is the
- one taken.
-
- Send Only Events
-
- The "S" event parameter was not documented in the manual.
- It designates an event which is "send only" meaning that
- BinkleyTerm will continue to send normally, but will not
- answer the phone (or if the modem is in auto-answer mode,
- BinkleyTerm will not respond).
-
- ---------
- SECTION 2 General Reference Information
- ---------
-
-
- TERMINAL MODE KEYSTROKES CHANGES AND ADDITIONS
-
- Alt-E
-
- Erases the display screen.
-
- Alt-I
-
- Re-initializes the modem.
-
- UNATTENDED MODE KEYSTROKES CHANGES AND ADDITIONS
-
- Alt-G
-
- Allows the generation of an outbound file request. When
- executed, this command will pop-up a window on the screen
- where you will be prompted to provide information
- appropriate to creating a file request. See 'Colors' in
- "Configuration File" for related information.
-
- Alt-I
-
- Re-initializes the modem (equivalent to Alt-T/Alt-U in
- previous BinkleyTerm versions). Also causes BinkleyTerm to
- re-read the outbound mail holding area.
-
- Alt-K
-
- Allows you to kill all mail for a particular node. When
- executed, you will be prompted for the appropriate
- information.
-
- Alt-S
-
- Allows the generation of an outbound file attach. When
- executed, this command will pop-up a window on the screen
- where you will be prompted to provide information
- appropriate to creating a file attach. See 'Colors' in
- "Configuration File" for related information.
-
- Alt-Y
-
- Polls the boss node (same as Alt-Y in Terminal Mode).
-
-
- --------------------------------------------------
- MISCELLANEOUS NOTABLE ITEMS ABOUT BINKLEYTERM 2.40
- --------------------------------------------------
-
- Time Slice Release
-
- In situations where BinkleyTerm would normally release time
- slice when used in a multi-tasking environment, it will now
- call the MS-DOS scheduler interrupt (int 28h for the
- technical among us) when running in a straight DOS
- environment. This will improve performance of any
- background tasks like print spoolers and networks.
-
- Mode Switching
-
- When switching from Terminal Mode to Unattended Mode,
- BinkleyTerm will switch back to using the port shown in the
- configuration file (if changed while in Terminal Mode).
-
- Multi-Taskers
-
- The PC-MOS operating system is now detected by BinkleyTerm
- at start-up, and if identified, time slice will be properly
- released when appropriate by BinkleyTerm to improve overall
- system performance.
-
- Foreign Language Capabilities
-
- This release of BinkleyTerm allows you to generate your own
- translations or modifications of much of the BinkleyTerm
- internal text. Enclosed with this release is a file named
- ENGLISH.TXT, which is the raw English language text created
- by the authors, and BINKLEY.LNG which is the compiled binary
- representation of ENGLISH.TXT for BinkleyTerm's use.
-
- To create your own translation of BinkleyTerm's text
- strings, copy the ENGLISH.TXT file to a file of your choice
- for editing. Use a standard ASCII flat text file editor
- (such as DOS EDLIN or your favorite word processor in non-
- document mode) to edit the file for your needs. The strings
- should in most cases be self-explanatory.
-
- When finished editing the file, use the included language
- compiler, BTLNG.EXE, to compile the text into binary format
- for BinkleyTerm's use. The command line for BTLNG.EXE is as
- follows:
-
- BTLNG <source_file> <output_file>
-
- For example, to compile the ENGLISH.TXT file, use the
- following command:
-
- BTLNG ENGLISH.TXT BINKLEY.LNG
-
- The binary language file must be named BINKLEY.LNG in order
- for BinkleyTerm to recognize it.
-
- Persons who are qualified (bilingual and sufficiently
- experienced or educated) to translate ENGLISH.TXT into
- foreign languages are encouraged to do so and to make your
- translations available to others through appropriate means.
-
- Filtering Negotiation Sequences
-
- In some situations, incoming MNP or V.42 negotiation
- sequences would cause BinkleyTerm to improperly respond to
- incoming callers. In this release, BinkleyTerm recognizes
- the negotiation sequences (if your modem does not filter or
- use them internally) and will properly discard them.
-
- ----------------------------------------------------
- DESCRIPTION AND OPERATION OF THE JANUS MAIL PROTOCOL
- ----------------------------------------------------
-
- NOTE: Janus is an EXPERIMENTAL protocol. It is not at this
- writing a documented FTSC standard. BinkleyTerm 2.40 represents
- the first implementation of Janus in a released software product,
- and is providing its first "real world" testing. With all of
- this in mind, it is important to understand that Bit Bucket
- Software cannot and does not provide any assurances or guarantees
- that Janus will work for you in your environment. PLEASE READ
- THIS SECTION IN ITS ENTIRETY IN ORDER TO UNDERSTAND AND PROPERLY
- IMPLEMENT JANUS. FAILURE TO DO SO WILL YIELD UNPREDICTABLE
- RESULTS!
-
- An Introduction to Janus
-
- Janus is a file transfer protocol specifically designed for WaZOO
- mail transfers. It can achieve Zmodem-like performance and
- reliability, with the major added benefit of being able to do
- transfers in both directions simultaneously. It is implemented
- as dual independent state machines; one for sending files, and
- one for receiving files. Both state machines run simultaneously,
- sharing the phone line. All data is exchanged in variable-length
- packets, with either a 16 or 32 bit CRC. Under ideal conditions,
- you can expect Zmodem-class performance going both ways at the
- same time.
-
- The bottom line is that when two machines exchange mail using
- Janus, the smaller of the two nodes' batches of files will be
- sent for free while the larger batch is being sent. If you poll
- your EchoMail feed nightly, and usually only send a couple of
- kilobytes while picking up a couple hundred, you won't get any
- real benefit from using Janus. But if you normally send 100kb
- and pick-up 200kb, you'll see significant time and money savings.
-
- However, even if you don't usually need to send and receive much
- data at once, and don't get much benefit from the full-duplex
- file transfers, you should get Zmodem-level performance even on
- one-way transfers, and so shouldn't have any penalty for using
- Janus rather than ZedZap (Zmodem). The idea is for the benefits
- to be there when you need them, without costing you anything
- extra if you don't.
-
- What You Should Be Aware Of
-
- There are some important considerations that you should be aware
- of before using Janus. Most importantly, Janus is a FULL DUPLEX
- protocol, and works best with a full-duplex connection. It's not
- a good idea to try and shove streaming, non-stop, full-duplex
- data through a half-duplex connection, since the modems will end
- up constantly flip-flopping the line around and retraining, and
- you'll get terrible performance.
-
- What this means is that normal low speed (1200 and 2400 baud)
- connections should work fine with Janus, and that high speed
- links that use V.32 should also work fine. High speed
- connections with high speed in one direction and a low speed back
- channel (such as an HST) will not allow Janus to work well at
- all.
-
- There are some other situations where Janus will not work very
- well. Many systems, modems and networks just don't seem to have
- the sustained bandwidth to allow full-duplex streaming data to be
- transferred accurately.
-
- Telenet's PC Pursuit service is a good example. The service has
- great difficulty with Janus, frequently dropping and mangling
- data. Janus simply saturates the capabilities of the packet
- switched connection.
-
- Some modems and even some serial port hardware doesn't seem to
- bear up very well under the tremendous load Janus can put on them
- either. This is probably to be expected, since full-duplex
- streaming protocols are rare, and the hardware has probably never
- been tested under this type of extreme, sustained load.
-
- The bottom line is that Janus may or may not work for you with
- your hardware, and if it does work, it may not work well on all
- connections. Its implementation in BinkleyTerm has been tested
- thoroughly, and works very well in many cases. You'll need to
- enable Janus (by default, Janus is not enabled) and test it
- yourself in your own environment to know whether Janus is a
- workable solution for you.
-
- +--------------------------------------------------------+
- | Bit Bucket Software cannot guarantee the performance |
- | and applicability of Janus. If Janus does not work |
- | for you in your environment, please do not bombard us |
- | with questions and comments about the protocol; simply |
- | disable Janus again (which it is by default). |
- +--------------------------------------------------------+
-
- Configuring Janus
-
- Your first consideration before using Janus is your FOSSIL driver
- buffer configuration. Janus really needs at least a 2kb receive
- buffer (or better yet, 3kb) and no more than about a 1kb transmit
- buffer (including whatever transmit buffering your modem does).
- The reason for the large receive buffer may be obvious; the
- largest packet Janus ever sends is 2kb, and while it's sending
- 2kb, you can obviously receive 2kb, which Janus won't be able to
- read from the FOSSIL until it's done sending. So up to 2kb of
- data can easily be received before Janus gets a chance to read
- any of it, and possibly a bit more in some situations. If your
- receive buffer is too small, you'll constantly lose incoming data
- and require massive numbers of retransmissions.
-
- The send buffer should be kept fairly small, because of the way
- the packets for the two directions are interleaved on the phone
- lines. If I'm receiving a large file from you while I'm sending
- you lots of small files, every time I finish sending you a small
- file I have to wait until I've received your entire send buffer's
- worth of data before I see the acknowledgement that says you
- received my file okay. If your send buffer is more than 1 or
- 2kb, this can end up wasting a lot of time.
-
- Configuration File Modifications
-
- IF YOU HAVE A LOW SPEED MODEM (2400 baud or under), then you will
- generally use the 'JanusBaud' statement in your configuration
- file. Set 'JanusBaud' to your highest supported baud rate.
-
- IF YOU HAVE A HIGH SPEED MODEM (9600 baud or above), then you
- might need to use a combination of 'JanusBaud' and 'JanusOK'
- statements in your configuration file. 'JanusBaud' should be set
- to the highest FULL DUPLEX baud rate you support. The only
- exception is if you have a multi-standard modem. Use the
- following as a guideline:
-
- Modem Type JanusBaud Statement
- -------------- -------------------
- V.32 Only JanusBaud 32767
- Non-V.32 Only JanusBaud 2400
- Multi-Standard JanusBaud 2400
-
- NOTE: 32767 is the maximum setting for 'JanusBaud.'
-
- If your high speed modem is single-standard, then 'JanusBaud' is
- all you will probably need to use. Multi-standard modems require
- 'JanusOK' statement(s) in order to take full advantage of high
- speed full duplex (V.32) connections when they occur.
-
- Your multi-standard modem should be set to return extended modem
- connect information. This information is appended to the end of
- the modem connect message, and can be used to determine what type
- of connection has been made in conjunction with the 'JanusOK'
- statement.
-
- In the case of a USRobotics HST Dual Standard, you will normally
- want to use Janus on V.32 connects, but not on HST connects. For
- example, these connect strings would indicate connections where
- Janus can be used:
-
- CONNECT 9600/Arq/V32
- CONNECT 9600/V32
-
- But a connection like this would not take advantage of Janus:
-
- CONNECT 9600/Arq/Hst
-
- NOTE: The extended connect information is not shown in all upper
- case, since BinkleyTerm will convert everything but the first
- character to lower case for display, automatically.
-
- You would permit Janus only on the desired connects, like this:
-
- JanusOK /Arq/V32
- JanusOK /V32
-
- Make certain that you also set 'JanusBaud' no higher than 2400,
- or your 'JanusOK' statements may not have the desired effect. In
- addition, you will probably want to dial out in V.32 mode if you
- frequently connect with multi-standard modems of the same make
- and model. This will allow Janus to be enabled on the maximum
- number of connections.
-
- If your multi-standard modem is not an HST Dual Standard, consult
- your modem manual for details extended connect information for
- your particular modem make and model.
-
- NOTE: In testing, it has been found that the "PEP" mode of the
- Telebit Trailblazer series modems can handle Janus, even though
- PEP mode is not full duplex. Throughput may not be as high as it
- would be on a true full duplex connection.
-
- ----------------------------------------------
- DESCRIPTION AND OPERATION OF DOMAIN ADDRESSING
- ----------------------------------------------
-
- Introduction
-
- Domain addressing is a relatively new concept in FidoNet, and
- represents an alternative, more complete method of designating
- various networks than the zone method now commonly in use. In
- theory, domain addressing adds an additional "layer" to address
- designation that represents a particular network. Within that
- network, zones and nets can all be specified without conflict to
- identical zones and nets in other networks.
-
- Domain support in BinkleyTerm requires you to use separate and
- distinct nodelist files for different domains. BinkleyTerm can
- now be used much more effectively in multiple network
- installations, assuming all the elements are configured properly.
-
- 'Address' Statement
-
- BinkleyTerm will accept a domain designation in any 'Address'
- statement in the configuration file. A domain is a valid
- Internet domain in most cases. For example, 1:104/501 might have
- the following in its configuration file:
-
- Address 1:104/501@fidonet.org
-
- At this writing, FidoNet is the only FidoNet technology network
- that is listed with Internet, but that is subject to change.
- Alternative networks should be designated by their "common" name
- followed by ".ftn" (for FidoNet technology network). For
- example, a node in Alternet might be designated as follows:
-
- Address 7:520/1015@alternet.ftn
-
- 'Domain' Statement
-
- There are several elements to successful domain implementation,
- in that nodelist and outbound areas change by domain. This
- information is given by you in the form of 'Domain' statements in
- your configuration file. The format of the 'Domain' statement is
- as follows:
-
- Domain <designator> <abbreviation> [<nodelist>]
-
- The <designator> is the actual domain name. As shown previously,
- FidoNet would be "fidonet.org" and Alternet would use
- "alternet.ftn" for the designator.
-
- The <abbreviation> is the abbreviated form of the domain name,
- and is LIMITED TO EIGHT (8) CHARACTERS. This name is passed in
- the packet header during a session. In most cases, this will be
- the common name of the network, such as "fidonet" or "alternet"
- in our examples.
-
- Finally, the optional <nodelist> parameter provides the base
- nodelist name to associate with this domain. If not given, it
- defaults to the same name given for the <abbreviation> parameter.
- In our examples, "nodelist" would be used for FidoNet, while
- "anetlist" would be used for Alternet.
-
- Here are two complete examples of the use of the 'Domain'
- statement, one for FidoNet, one for Alternet:
-
- Domain fidonet.org fidonet nodelist
- Domain alternet.ftn alternet anetlist
-
- NOTE: If you designate a domain in your 'Address' statement,
- then you must also create a corresponding 'Domain' statement.
-
- Outbound Area Naming
-
- The name of the outbound area also changes according the domain.
- As always, the outbound area for your primary address (including
- domain) is given with the 'Hold' statement.
-
- Outbound areas for other domains take an identical path, except
- the name of the last sub-directory is changed to the
- <abbreviation> parameter. For example, if your 'Hold' statement
- designates C:\BINKLEY\OUTBOUND for an outbound holding area (and
- you are in FidoNet), Alternet outbound mail would be held in the
- C:\BINKLEY\ALTERNET.xxx directory instead. Note that outbound
- areas for domains other than your own will ALWAYS have a zone
- extension.
-
- Working Example
-
- If you're thoroughly confused at this point, possibly a working
- example will help. Assume that a configuration file has the
- following:
-
- Hold c:\bink\outbound
- Address 1:104/501@fidonet.org
- Domain fidonet.org fidonet nodelist
- Domain alternet.ftn alternet anetlist
- Domain eggnet.ftn eggnet egglist
-
- The nodelist files would be as follows:
-
- NODELIST.* (for FidoNet)
- ANETLIST.* (for Alternet)
- EGGLIST.* (for Eggnet)
-
- The examples of outbound holding areas are as follows:
-
- c:\bink\outbound (Default Outbound)
- c:\bink\outbound.002 (FidoNet Zone 2)
- c:\bink\outbound.003 (FidoNet Zone 3)
- c:\bink\outbound.004 (FidoNet Zone 4)
- c:\bink\outbound.005 (FidoNet Zone 5)
- c:\bink\alternet.007 (Alternet Zone 7)
- c:\bink\alternet.059 (Alternet Zone 89)
- c:\bink\eggnet.063 (Eggnet Zone 99)
-
-