home *** CD-ROM | disk | FTP | other *** search
- To PRINT README file to use as reference manual type;
- PRINT README <Return>
-
-
- U-NET INSTALLATION
-
- The following files need to be on your Installation Diskette;
- UINSWKST.CFG INSTALL.EXE S-PRINT.EXE
- UNET.SYS UNET.EXE W-PRINT.EXE
- UINSHOST.CFG
- Insert the Installation Diskette in Drive A of the computer designated to
- become the SERVER (the computer whose hard disk drive(s) and printer you wish
- to share) and type in; A: <Return>
- INSTALL <Return>
- Select the appropriate option (SERVER) using the arrow keys and INSTALL will
- copy the appropriate files to the hard disk drive of the computer designated
- as the SERVER. Select Exit when this is completed.
-
- Now insert the Installation Diskette in the other computer (called the
- WORKSTATION) and type in; A: <Return>
- INSTALL <Return>
- Select the appropriate WORKSTATION option depending if the WORKSTATION
- Computer has a hard disk drive or just floppy drive(s). You will be prompted
- to change diskettes several times if you have only floppy drive(s) on your
- WORKSTATION Computer. Ensure that you have at least 15Kb free space available
- to allow for copying of files onto your boot disk. Select Exit when completed.
-
-
- RUNNING U-NET
-
- Simply type on the SERVER;
- C: <Return>
- UNET <Return>
- Be sure to REBOOT the WORKSTATION once the cable is connected between the
- Parallel Ports on the computers. The cable should be connected to LPT2 if
- there is more than one Parallel Port in the computer. (See next section for
- Cable Requirement)
-
- You will notice on the WORKSTATION that extra virtual drives appear (being
- the SERVER'S drives). They can be accessed as though they were physically
- present in the WORKSTATION Computer by using normal DOS commands.
-
- Both the SERVER and the WORKSTATION retain all of the features they had as
- standalone computers, however now the WORKSTATION can concurrently access
- the SERVER'S hard disk drive(s) and printer.
-
- To access the SERVER'S printer from the WORKSTATION type at the DOS prompt;
- S-PRINT <Return>
- and if you wish to print locally at the WORKSTATION printer then type;
- W-PRINT <Return>
- The WORKSTATION printing normally defaults to it's local printer on booting up.
-
-
-
- CABLE REQUIREMENTS
-
- U-Net requires linking together of the two computers using standard Parallel
- Ports with a special cable. You can either make this yourself as described
- below or order at low cost from the Authors (see later section).
-
- We recommend a maximum distance of 50ft between computers and have available
- standard 20ft(6m) and 50ft(15m) fully tested data grade cables.
-
- Use data grade cable, 11 wires with shield and male DB-25 connectors. Wiring
- is as follows;
-
- Pin 2 to Pin 15
- 3 -- --- 13
- 4 -- --- 12
- 5 -- --- 10
- 6 -- --- 11
- 10 -- --- 5
- 11 -- --- 6
- 12 -- --- 4
- 13 -- --- 3
- 15 -- --- 2
- 25 (Also connect to shield) 25 (Also connect to shield)
-
-
-
- CABLES, REGISTRATION & EXTRA PARALLEL PORTS
-
- CABLES Standard 20ft (6m) $19.95 + $5.00 shipping
- Standard 50ft (15m) $39.95 + $5.00 shipping
- (Note: This includes Registration of the software)
-
- REGISTRATION Registration Only $9.95
- (License, Tech Support, BBS, Upgrades, Newsletters)
-
- PARALLEL PORTS Parallel Port (ISA) $9.95 each + $5.00 shipping
-
- PAYMENT Check, Money Order, COD (Add $5.00 for CODs)
- Overseas freight collect
- Please be sure to include with your order;
- NAME & SHIPPING ADDRESS
- PHONE NUMBER
- CHECK or MONEY ORDER (No Credit Card Payments)
- ADD $5.00 if you require C.O.D. (only available in USA)
- THE PRODUCTS YOU REQUIRE
-
- The address to send to is;
- Creative Technology
- P O Box 14153, Scottsdale
- AZ 85267-4153, USA
-
-
-
-
- U-NET FEATURES
-
- * Easy installation on any IBM Compatible Computer (including PS/2
- Microchannel) by simply plugging into the Parallel Port on each computer.
-
- * No learning required as U-Net is transparent to the user who is left in
- a familiar DOS environment. The SERVER Computer's hard drive(s) are
- simply appended to the WORKSTATION Computer's drive(s) as additional
- virtual drives and accessed in a normal DOS manner.
-
- * U-Net allows the concurrent sharing of the SERVER (or Host) computer's
- hard disk drive(s), (including RAM disks and some CDROMs) and printer
- attached to LPT1.
-
- * U-Net gives you the ability to share software and datafiles when using
- LAN or multi-user versions of your application software by running SHARE
- (a DOS program included in DOS 3.3 and later) which gives you file and
- record locking facilities.
-
- * Printing from the WORKSTATION computer can be redirected to the SERVER'S
- printer by typing S-PRINT (SERVER Printing) and W-PRINT (WORKSTATION
- Printing) when at the DOS prompt. (Default is W-PRINT, setting remains
- the same until printer command is changed or WORKSTATION is rebooted).
-
-
-
- U-NET PROGRAM FILES
-
- UINSWKST.CFG - This file stores the WORKSTATION Computer parameters U-Net
- requires.
-
- UNET.SYS - This is the device driver program that allows your WORKSTATION
- Computer to access the SERVER Computer. It adds approximately 8Kb to the memory
- used on your WORKSTATION Computer.
-
- UINSHOST.CFG - This file stores the SERVER Computer parameters U-Net requires
-
- INSTALL.EXE - This is the initial installation program that gives you the
- choice of SERVER or either WORKSTATION with a hard disk drive or WORKSTATION
- with only floppy disk drive(s). It automatically copies the appropriate files
- onto the computers, checks the port addresses and configures the system
- accordingly. It adds a line to the WORKSTATION Computer's config.sys file,
- device=unet.sys which needs removing if you do not want to run the network.
-
- UNET.EXE - This is the Terminate-Stay-Resident (TSR) program that is executed
- on the SERVER Computer to allow the WORKSTATION Computer to communicate with
- it. This program takes approximately 30Kb of the SERVER'S first 640Kb RAM.
-
- S-PRINT.EXE - This program run on the WORKSTATION Computer simply switches
- the redirection of any printing from the WORKSTATION to the SERVER'S printer.
-
- W-PRINT.EXE - This program run on the WORKSTATION Computer switches the
- redirection of printing back from the SERVER Computer's printer to the printer
- attached to the WORKSTATION.
-
-
- TECHNICAL REQUIREMENTS, RECOMENDATIONS AND TROUBLE SHOOTING
-
- * It is recommended that you use MSDOS 3.3 or later and the same version of
- DOS on both computers.
-
- * The cable must be connected to the LPT2 Port if there is more than one
- parallel port in the computer.
-
- * U-Net software takes 30Kb (approx) of the SERVER'S first 640Kb RAM and
- 8Kb on the WORKSTATION Computer.
-
- * Only use SHARE on the SERVER computer if you are using multi-user or LAN
- versions of your application software as it takes up memory and will slow
- performance.
-
- * OEM versions of DOS (such as Zenith, NEC) and some Disk Manager
- Partitioning Software which does not support standard sector lengths may
- need changing. (Usually gives execute failure or error when changing
- directories). Use DOS FDISK to format hard disk drives to avoid problems.
-
- * Some "non-compatible" IBM clones; some Tandy models, Amstrad, etc are not
- fully compatibile and will not work.
-
- * Mixtures of DOS between SERVER and WORKSTATION can give problems.
-
- * Computer Games and Formatting of Diskettes should be avoided on the
- SERVER Computer while U-Net is running as this can cause problems.
-
- * Number of files open in the Config.Sys file on the SERVER may need
- increasing as it must open enough files for the WORKSTATION also.
-
- * If WORKSTATION programs are halted abnormally then it may be necessary to
- reboot the SERVER to ensure any open files are closed.
-
- * If using different screen types (mono and color) then a sub-directory on
- the SERVER with different configurations of the software may be required.
-
- * Sometimes PATH commands and AUTOEXEC files on the WORKSTATION need
- modifying to allow for software and data files residing on different
- virtual drives.
-
- * There may be a conflict in the SERVER between the U-Net software and some
- other TSRs running. If this occurs you should ensure that U-Net loads
- first which may solve the problem.
-
- * Always carefully check that the cable is correctly connected should
- communication not be established.
-
- * Cables of too great a length or inadequate quality can give problems.
-
- * ERROR - SERVER not responding. U-Net installation cancelled - usually
- indicates that the Device Driver, UNET.SYS is in the config.sys file
- correctly on the WORKSTATION, but either the SERVER is not running the
- program UNET or the cable is not connected.