home *** CD-ROM | disk | FTP | other *** search
/ ProfitPress Mega CDROM2 …eeware (MSDOS)(1992)(Eng) / ProfitPress-MegaCDROM2.B6I / MISC / HANDICAP / FUTUR201.ZIP / README < prev    next >
Encoding:
Text File  |  1992-01-22  |  9.3 KB  |  230 lines

  1. ╒════════════════╕
  2. │ FUTURA TDD II  │        Full version 2.01                 January 23, 1991
  3. ╘════════════════╛
  4.  
  5. Written by Norman Williams, a deaf programmer.
  6.  
  7.     Futura Wave Communications
  8.     Norman Williams
  9.     3506 Commodore Barney Dr. NE #T-2
  10.     Washington, DC 20018
  11.  
  12.     (c) Copyright '90, '91, and '92. All Rights Reserved.
  13.  
  14.  
  15.  
  16. ──────────────────────────
  17.     Please upload this unmodified FUTUR201.ZIP file to any BBS, even
  18.     if you don't use a TDD. There are a lot of people who want to
  19.     communicate with deaf people on the phone. Very few BBS have a
  20.     program to work with a TDD. So please do not modify this program.
  21.  
  22.  
  23. FOR PEOPLE WHO NEED TO KNOW WHAT A TDD IS:
  24. ──────────────────────────────────────────
  25.     TDD is an abbreviation of Telephone Device for the Deaf.
  26.     Deaf people communicate with each other using the old─fashioned baudot
  27.     mode with 5 bits, at 45.45 baud. Hayes compatible modems are NOT
  28.     compatible with TDDs. This is due to different tones generated by the
  29.     TDD modem which uses frequencies at 1800 and 1400 hertz. So a special
  30.     modem for the deaf is needed.
  31.  
  32.  
  33. REQUIREMENTS:
  34. ─────────────
  35.     ■ Krown Research Smart Modem SM─85H, or Ultratec Intele─Modem,
  36.       Hayes or Phone─TTY CM─4 TDD Modem.
  37.     ■ IBM PC, XT, AT, PS/2, or 100% compatibles.
  38.     ■ Monochrome Display Adapter, Color Graphics Adapter (CGA),
  39.       Enhanced Graphics Adapter (EGA), Multi─Color Graphics Array
  40.       (MCGA), or Video Graphics Array (VGA).
  41.     ■ Serial Port (COM 1─4).
  42.     ■ 240K minimum RAM.
  43.     ■ DOS version 2.0 or higher.
  44.  
  45. INSTALLATION:
  46. ─────────────────────────
  47.     Just type INSTALL and press ENTER. Follow the instructions on the
  48.     screen.
  49.  
  50. EXECUTING AND SHORT─CUTS:
  51. ─────────────────────────
  52.     Execute the program by typing TDD and press ENTER at your DOS prompt.
  53.     Your best friend for learning how to use the program is using ALT-Z in
  54.     any part of the program. To press ALT-Z key, just press and hold the
  55.     ALT key and press Z key. The ALT-Z is a help screen related to current
  56.     functions. In other words, not all help screens are the same for each
  57.     function. After playing with every command outlined in all help screens,
  58.     you should be able to master this TDD program.  When modem selection
  59.     is set to "None", press NUMS Lock to simulate other user's typing.
  60.     This way you can try out the Futura-TDD software without a modem. With
  61.     a Hayes compatible modem, you can try a call to a relay service in ASCII.
  62.  
  63.  The command lines for the TDD program are:
  64.      TDD -A to ANSWER incoming line now.
  65.      TDD -Ax to ANSWER incoming line now with function key #x [x=1..10].
  66.      TDD -D to go to DIRECTORY directly.
  67.      TDD -M to go MESSAGE CENTER and use setup's message selection.
  68.      TDD -Mx to go MESSAGE CENTER and use message #x [x= 1,2,3]
  69.      TDD -Z to go to the main menu directly.
  70.      TDD -MONOVGA to work with better colors on a Mono-VGA system.
  71.      TDD alone to enter to Futura-TDD.
  72.  
  73. WINDOW'S PIF FILES:
  74. ──────────────────
  75.     386/486 Computers with 2mb or more: Use TDD386.PIF file. The hot key for
  76.     the program is CTRL-ALT-F. Use it whereever you are in. The TDD will run
  77.     in background to take messages even if other program is running.
  78.  
  79.     286/8086 Computers: Use TDD.PIF file. There is no hot key. Also will not
  80.     run in background due to CPU's limitations.
  81.  
  82. DIFFERENCES OF TRIAL AND FULL VERSION:
  83. ──────────────────────────────────────
  84.     Distribute this trial version to anyone. This trial version will give you
  85.     an opportunity to try this program out to see if it will meet your needs.
  86.  
  87.     TRIAL VERSION:
  88.        ■ 5 minutes limit on each call except when calling to a Futura user.
  89.        ■ Only 1 message taking feature is accepted.
  90.        ■ Short cut parameters on command line not supported.
  91.        ■ Remote on real calls not supported. (Remote on Notes supported).
  92.  
  93.     FULL VERSION:
  94.        ■ Unlimited time on each call.
  95.        ■ Unlimited message taking is supported.
  96.        ■ No trial screen.
  97.        ■ Short cut parameters on command line supported: Ex: TDD ─M will
  98.          go to auto─message directly from DOS. TDD ─A will answer line
  99.          directly from dos.
  100.        ■ Remote on real calls supported.
  101.  
  102. TO ORDER TDD MODEMS:
  103. ───────────────────────────────────────
  104.     Phone─TTY CM─4: Phone─TTY, Inc.
  105.     ($349)      202 Lexington Ave.
  106.             Hackensack, New Jersey 07601
  107.             (201) 489-7889 (Voice)
  108.             (201) 489-7890 (TDD)
  109.             (201) 489-7891 (FAX)
  110.             (201) 489-3323 (Dial-A-News)
  111.  
  112.     ADVANTAGES:
  113.        ■ Best TDD/ASCII compatible.
  114.        ■ Fastest initializing modem.
  115.        ■ 100% of ASCII connection with Hayes compatible modems.
  116.        ■ Auto Baudot/ASCII selection in incoming calls.
  117.        ■ Will drop to Baudot if ASCII carrier is lost.
  118.        ■ Supplied with communication software Futura II and PC/TDDA.
  119.  
  120.     DISADVANTAGES:
  121.        ■ No auto Baudot/ASCII selection on outgoing calls.
  122.        ■ No touchtone dialing. Fast dialing in software emulates this.
  123.      (May or may not trigger phone light systems when dialing)
  124.  
  125.     ─────────────────────────────────────────────────────────────────
  126.     Ultratec Intele─Modem:
  127.             Ultratec
  128.     ($329)      450 Science Drive
  129.             Madison, Wisc 53711
  130.             (608) 238-5400 (Voice/TDD)
  131.  
  132.     ADVANTAGES:
  133.        ■ Redials on busy calls.
  134.        ■ Auto ASCII/Baudot selection on incoming and outgoing calls.
  135.        ■ Built-in speaker.
  136.        ■ Touchtone/pulse dialing.
  137.  
  138.     DISADVANTAGES:
  139.        ■ Connects with roughly 50% of Hayes compatible modems.
  140.        ■ Disconnects when ASCII carrier is lost.
  141.          (will not drop down to Baudot).
  142.        ■ Does not come with communication software.
  143.     ──────────────────────────────────────────────────────────────────
  144.     Krown Research Smart Modem:
  145.             Krown Research, Inc.
  146.     ($349)      129 Sheldon Street
  147.             El Segundo, CA 90245
  148.             (213) 322-3202 (Voice/TDD)
  149.             (213) 839-0181 (Voice/TDD)
  150.  
  151.     ADVANTAGES:
  152.      ■ Touchtone/pulse dialing.
  153.  
  154.     DISADVANTAGES:
  155.      ■ If an extension phone is a pulse dialer, it will confuse
  156.        Futura-TDD to think the phone is ringing.
  157.      ■ ASCII can not work with Futura-TDD.
  158.      ■ Does not come with communication software.
  159.     ─────────────────────────────────────────────────────────────────
  160.  
  161. TO ORDER EXTERNAL CALLER-ID BOARD FOR YOUR PC:
  162. ────────────────────────────────────────────────────────
  163.     So far, I know of two vendors who can provide the device for the PC:
  164.  
  165.           ■ International MicroPower Corp. (800) 992-3511.
  166.            Caller-ID #IMC-CID-1A.  Requires internal battery or
  167.            DC adapter. Sells for $45.00 without their software.
  168.            Hobbyist quality. 
  169.  
  170.           ■ Phone─TTY CM─4: Phone─TTY, Inc.
  171.            ($100)       202 Lexington Ave.
  172.                 Hackensack, New Jersey 07601
  173.                 (201) 489-7889 (Voice)
  174.                 (201) 489-7890 (TDD)
  175.                 (201) 489-7891 (FAX)
  176.                 (201) 489-3323 (Dial-A-News)
  177.            Caller ID+Plus.  Requires no external power source.
  178.            Small as a gender changer. Professional quality.
  179.  
  180. TO UPLOAD TO BBS THE TRIAL VERSION, PLEASE USE THE FILE:
  181. ────────────────────────────────────────────────────────
  182.     FUTUR201.ZIP
  183.  
  184. CHECK FILES IN FULL VERSION
  185. ────────────────────────────
  186. The files for this full version should have 10 files:
  187.  
  188.     ■ TDD.EXE        (TDD program)
  189.     ■ DIRECTRY.TDD   (All phone numbers/names)
  190.     ■ README.        (This file)
  191.     ■ README.BAT     (To read this file)
  192.     ■ EXAMPLE.TXT    (Example file for transmitting a file to TDD)
  193.     ■ INSTALL.EXE    (To install)
  194.     ■ FUTUR201.ZIP   (Trial package)
  195.     ■ HELP.TDD       (Help file)
  196.     ■ TDD.PIF        (For Windows 3.0 in standard/real mode)
  197.     ■ TDD386.PIF     (For Windows 3.0 in enhanced mode)
  198.  
  199. HISTORY OF REVISIONS ********************************************************
  200.  
  201. VERSION 2.01 (Jan 23, 1992) =================================================
  202.   ■ Improved remote examples in HELP file! (In notes and remote setup help)
  203.   ■ When the ASCII checking is off with Intele-modem. It didnt send anything
  204.     in auto message or by a function key. Fixed.
  205.   ■ TRIAL VERSION: No time limit when calling to a Futura in ASCII.
  206.   ■ Improved the "Erase, Save, Print,.." window (after hanging up).
  207.   ■ The "*" on keyboard will now be treated as "*" instead of time greeting. 
  208.     Only for when on-line/user keyboard and file sending.
  209.   ■ When deleting a middle empty folder, it said to rename it. Now will delete
  210.     the folder nicely.
  211.   ■ Caller-ID info not saved properly when in remote. Was cutted off. Fixed.
  212.   ■ Quicker to initialize Intele-modem/Hayes if modem was off.
  213.   ■ Caller-ID Block detection is added.
  214.   ■ GENERAL SETUP: Screen saver's prefix is changed from "M." to "S." because 
  215.     of other same prefix "M." already for multi-users/single user.
  216.   ■ Prevented CTRL-BREAK to break out.
  217.   ■ Deleted Pan Am from the directory. They no longer are in business.
  218.   ■ CM-4 MODEM: Will auto answer when running to already on-line.
  219.   ■ Crashed after deleting last review in a folder and pressing END. Fixed.
  220.   ■ Improved the demo of remote to other side. Remote will be disabled once the
  221.     Futura-TDD user on the PC pressed a key during remote.
  222.   ■ Improved the text file sending to a BBS when in full duplex.
  223.   ■ Added the TDD ? in the readme file.
  224.   ■ Reworded first two lines in main menu.
  225.   ■ Backs out after pressing the ESC key in baud speed window.
  226.   ■ Added instructions of how to delete in the function key editing window.
  227.   ■ Fixed the "||| MANUAL |||" color problem when interrupting auto answer.
  228.   ■ Directory while on-line & ENTER. Added "X. To exit".
  229.  
  230.