home *** CD-ROM | disk | FTP | other *** search
Text File | 1994-10-13 | 67.1 KB | 2,078 lines |
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- HydraCom Version 1.00
-
- A sample implementation of the
- HYDRA Bi-Directional File Transfer Protocol
-
- HydraCom was written by
- Arjen G. Lentz, LENTZ SOFTWARE-DEVELOPMENT
- COPYRIGHT (C) 1991-1993; ALL RIGHTS RESERVED
-
- The HYDRA protocol was designed by
- Arjen G. Lentz, LENTZ SOFTWARE-DEVELOPMENT and
- Joaquim H. Homrighausen
- COPYRIGHT (C) 1991-1993; ALL RIGHTS RESERVED
-
-
-
- Blank page HydraCom
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Blank page HydraCom
-
-
-
- HydraCom Table of contents Page i
-
-
- 1 General Information . . . . . . . . . . . . . . . . . . . . 1
- 1.1 Protocol information . . . . . . . . . . . . . . . . 1
- 1.2 Program description . . . . . . . . . . . . . . . . 1
- 1.3 Program features . . . . . . . . . . . . . . . . . . 2
- 1.4 System hard- and software requirements . . . . . . . 2
- 1.5 Disclaimer . . . . . . . . . . . . . . . . . . . . . 2
- 1.6 HydraCom / source license . . . . . . . . . . . . . 3
- 1.7 Hydra protocol license . . . . . . . . . . . . . . . 4
- 1.8 Credits . . . . . . . . . . . . . . . . . . . . . . 5
- 1.9 Acknowledgements . . . . . . . . . . . . . . . . . . 5
- 1.10 Hydra in other software (also FidoNet mailers!) . . 5
- 1.11 Other environments/operating systems . . . . . . . . 5
- 1.12 Where to send your spare funds . . . . . . . . . . . 6
- 1.13 Support and contact addresses . . . . . . . . . . . . 6
-
- 2 Description of specific features . . . . . . . . . . . . . . 7
- 2.1 Split screen chat during a Hydra session . . . . . . 7
- 2.2 Resuming aborted transfers . . . . . . . . . . . . . 7
- 2.3 Networks and Multitaskers . . . . . . . . . . . . . 7
- 2.4 Using a FOSSIL driver . . . . . . . . . . . . . . . 9
- 2.5 Using a Video FOSSIL . . . . . . . . . . . . . . . . 9
- 2.6 AutoStart Hydra transfers . . . . . . . . . . . . . 10
- 2.7 Aborting a Hydra transfer . . . . . . . . . . . . . 10
- 2.8 Configuration utility HydraCfg . . . . . . . . . . . 10
- 2.9 Reliability . . . . . . . . . . . . . . . . . . . . 11
- 2.10 Protocol performance . . . . . . . . . . . . . . . . 11
- 2.11 HST and other half-duplex links . . . . . . . . . . 12
-
- 3 Commands and Options . . . . . . . . . . . . . . . . . . . . 13
- 3.1 Options . . . . . . . . . . . . . . . . . . . . . . . . 14
- 3.1.1 port N . . . . . . . . . . . . . . . . . . . . . 14
- 3.1.2 speed N . . . . . . . . . . . . . . . . . . . . 14
- 3.1.3 line N . . . . . . . . . . . . . . . . . . . . . 14
- 3.1.4 parity . . . . . . . . . . . . . . . . . . . . . 15
- 3.1.5 dropdtr . . . . . . . . . . . . . . . . . . . . 15
- 3.1.6 nocarrier . . . . . . . . . . . . . . . . . . . 15
- 3.1.7 noinit . . . . . . . . . . . . . . . . . . . . . 15
- 3.1.8 handshake <flg> . . . . . . . . . . . . . . . . 15
- 3.1.9 log <file> . . . . . . . . . . . . . . . . . . . 15
- 3.1.10 level <loglevel> . . . . . . . . . . . . . . . . 16
- 3.1.11 result <filename> (DSZ logfile) . . . . . . . . 16
- 3.1.12 noresume . . . . . . . . . . . . . . . . . . . . 16
- 3.1.13 nostamp . . . . . . . . . . . . . . . . . . . . 17
- 3.1.14 receive <path> . . . . . . . . . . . . . . . . . 17
- 3.1.15 nobell . . . . . . . . . . . . . . . . . . . . . 17
- 3.1.16 mailer . . . . . . . . . . . . . . . . . . . . . 17
- 3.1.17 nooriginator . . . . . . . . . . . . . . . . . . 17
- 3.1.18 hdxlink . . . . . . . . . . . . . . . . . . . . 17
- 3.1.19 txwindow N . . . . . . . . . . . . . . . . . . . 18
- 3.1.20 rxwindow N . . . . . . . . . . . . . . . . . . . 18
- 3.1.21 link options . . . . . . . . . . . . . . . . . . 18
- 3.2 Commands . . . . . . . . . . . . . . . . . . . . . . . . 19
- 3.2.1 send [<filespec> ...] [@<ctlfile> ...] . . . . . 19
-
-
- HydraCom Page i
-
-
-
- Page ii Table of contents (continued) HydraCom
-
- 3.2.2 get [<path>[<name>]] . . . . . . . . . . . . . . 20
- 3.2.3 term . . . . . . . . . . . . . . . . . . . . . . 20
- 3.3 Default configuration file . . . . . . . . . . . . . . . 21
-
- 4 Using HydraCom as an external protocol . . . . . . . . . . . 22
- 4.1 Interface methods . . . . . . . . . . . . . . . . . . . 22
- 4.1.1 Opus-style external protocol interface . . . . . 22
- 4.1.2 DSZ-style external protocol interface . . . . . 23
- 4.1.3 Exit codes (errorlevels) . . . . . . . . . . . . 23
- 4.2 Using HydraCom with terminal programs . . . . . . . . . 24
- 4.2.1 Telix . . . . . . . . . . . . . . . . . . . . . 24
- 4.2.2 Communique . . . . . . . . . . . . . . . . . . 24
- 4.2.3 Commo . . . . . . . . . . . . . . . . . . . . . 25
- 4.2.4 Procomm Plus . . . . . . . . . . . . . . . . . . 25
- 4.2.5 TeleMate . . . . . . . . . . . . . . . . . . . . 26
- 4.2.6 Boyan . . . . . . . . . . . . . . . . . . . . . 26
- 4.2.7 Qmodem . . . . . . . . . . . . . . . . . . . . . 27
- 4.3 Using HydraCom with BBS software . . . . . . . . . . . . 28
- 4.3.1 Maximus . . . . . . . . . . . . . . . . . . . . 28
- 4.3.2 Opus . . . . . . . . . . . . . . . . . . . . . . 28
- 4.3.3 QuickBBS and RemoteAccess (FileDoor) . . . . . . 29
- 4.3.4 RBBS-PC . . . . . . . . . . . . . . . . . . . . 29
- 4.3.5 Wildcat! . . . . . . . . . . . . . . . . . . . . 29
- 4.3.6 XBBS . . . . . . . . . . . . . . . . . . . . . . 31
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Page ii HydraCom
-
-
-
- HydraCom Page 1
-
- 1 General Information
-
-
- 1.1 Protocol information
-
- Full specifications of the Hydra protocol as well as the HydraCom
- sources (in C) are freely available. Developers may use either or both
- to implement Hydra into their own software, port Hydra to other
- machines and operating environments, etc.
- The packages containing these files have been widely distributed, but
- will always be available from the authors' own systems.
- Please refer to the license and other important information further
- along this document.
-
-
- 1.2 Program description
-
- HydraCom is a stand-alone driver which implements the Hydra
- bidirectional file transfer protocol developed by Arjen Lentz and
- Joaquim Homrighausen.
-
- HydraCom provides a service for communications programs which do not
- (yet) have with Hydra support internally. HydraCom can be installed as
- an external transfer protocol driver like other external drivers.
- HydraCom also provides a simple terminal function.
- Because HydraCom's sources are available, they can also serve as a
- sample implementation of the Hydra protocol for other developers to
- take a look at.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- HydraCom Page 1
-
-
-
- Page 2 HydraCom
-
- 1.3 Program features
-
- - Simultanous bidirectional file transfer
- - Split screen chat during Hydra session, without line noise
- - Comprehensive manual for installation and advanced features
- - Program source code and protocol specification freely available
- - Stand alone or external call from any BBS or terminal software
- - Compatible with both Opus and DSZ style interfacing
- - Hydra (and HydraCom) can be used in FidoNet Technology Mailers
- - Userfriendly full-screen setup utility HydraCfg, mouse supported
- - Good stability on bad connections, speedy error recovery
- - Safe protocol, no deadlocks or misunderstandings
- - Tolerance towards network and satellite delays
- - Handles 7-bit or even less transparent connections
- - Seperate escaping options for Telenet, XON/XOFF, 7bit, etc
- - Maximum performance without ever compromising reliability
- - All packets (including chat packets) protected by CCITT CRC-32
- - Retain file's original size and date/time
- - Automatic startup with special character sequence (AutoStart)
- - Resume aborted transfers without unfinished files floating about
- - Numerous transfer options for sysop and users
- - Supports FOSSIL and VideoFOSSIL
- - Internal communication routines supporting 16550 UART
- - Hardware and software flow control
- - Shared file open for network operation
- - Internal small terminal with ANSI/VT100 emulation and AutoStart
- - Fast screen writes, DESQview aware
- - Releases spare CPU time to DESQview or DOS
-
-
- 1.4 System hard- and software requirements
-
- - IBM XT, XT286, AT286, 386, 486, PS/2 or clone/compatible
- computers.
- - MS, PC or compatible DOS version 3.00 or higher.
- - About 128K of free memory space.
- - HydraCom is able to operate with certain non IBM-compatible serial
- hardware, provided a suitable FOSSIL and perhaps video FOSSIL
- driver is installed. There are various FOSSIL drivers available
- for true compatibles, like Opus!Comm, X00 and BNU, but also for
- the Tandy 2000, Heath Zenith, DEC Rainbow, Philips :YES and many
- others. Some of those are implemented as TSR (Terminate and Stay
- Resident) programs, others (like X00.SYS and BNU.SYS) as device
- drivers.In addition, use of a Video FOSSIL is supported.
-
-
- 1.5 Disclaimer
-
- This program is provided "as is" and comes with no warranties of any
- kind, either expressed or implied. In no event shall the authors be
- liable to you or anyone else for any damages, including any lost
- profits, lost savings or other incidental or consequential damages
- arising out of the use or inability to use this software.
-
-
-
- Page 2 HydraCom
-
-
-
- HydraCom Page 3
-
-
- 1.6 HydraCom / source license
-
- HydraCom, its associated utilities (HydraCfg) and the HydraCom
- sourcecode may be freely distributed, copied and used, no fee charged.
- All files, executables and sourcecode remain the copyrighted property
- of Arjen G. Lentz and LENTZ SOFTWARE-DEVELOPMENT.
- The distribution archives should remain intact with no files removed
- or modified. For special purposes, it is allowed to repack the
- archives using a different compression system.
-
- HydraCom may be bundled up with for instance terminal or BBS packages,
- even commercial ones, provided the buyer/user is clearly informed
- about the fact that Hydra and HydraCom are free, not owned by the
- distributor/retailer in question, and is not included in any possible
- charge regarding the rest of the package. This documentation must also
- be present so the user can inform himself about Hydra and HydraCom.
- The same rules apply to inclusion in shareware and CD-ROM libraries.
- In all cases, the author of HydraCom must be given credit in any
- informational screens and literature that contain such information.
-
- The Hydra/HydraCom sourcecode may also be freely used and integrated
- into other software or library, provided this is clearly stated in any
- informational screens and literature pertaining to this program, and
- credit is given to the original author. If the sourcecode of that
- program or library is released or otherwise published, the notices
- present at the top of every Hydra/HydraCom source file must be
- retained in their original unmodified form.
-
- In addition to the above license, everyone using any part of the
- sourcecode, programs or files is fully bound by the general license of
- the Hydra protocol as present in the Hydra protocol description
- document. For easy reference, the paragraph in question is reprinted
- below.
-
- Any use of, or operation on (including copying/distributing) any of
- the above mentioned files implies full and unconditional acceptance of
- this license and disclaimer.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- HydraCom Page 3
-
-
-
- Page 4 HydraCom
-
- 1.7 Hydra protocol license
-
- You are granted a license to implement the HYDRA file transfer
- protocol, HYDRA hereafter, in your own programs and/or use the sample
- source code and adapt these to your particular situation and needs;
- subject to the following conditions:
-
- - You must refer to it as the HYDRA file transfer protocol, and you
- must give credit to the authors of HYDRA in any information
- screens or literature pertaining to your programs that contains
- other such information (credits, your own copyrights, etc.).
-
- - HYDRA will always remain backwards compatible with previous
- revisions. HYDRA allows for expansion of its features without
- interfering with previous revisions. It is, however, important
- that different people do not expand the protocol in different
- directions. We therefore ask you to contact us if you have any
- needs/ideas regarding HYDRA, so development can be synchronized
- and beneficial to all.
-
- - If your implementation cannot converse with past or future
- revisions as supplied by us, then you must refer to it as "HYDRA
- derived", or as "a variation of HYDRA", or words to that effect.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Page 4 HydraCom
-
-
-
- HydraCom Page 5
-
- 1.8 Credits
-
- Zygimantas Cepaitis, Jan Stozek, Jac Kersing, Joaquim Homrighausen,
- Jeroen van Drie, Martin Cleaver, Henk Wevers, Jan Bredenbeek, Ron van
- der Nagel, and all other equally friendly creatures of the universe
- and cyberspace are hereby saluted in gratitude for their diverse
- efforts regarding the Hydra protocol and this software.
-
- HYDRA was designed by Arjen G. Lentz, LENTZ SOFTWARE-DEVELOPMENT, and
- Joaquim H. Homrighausen.
-
-
- 1.9 Acknowledgements
-
- - IBM PC, XT, AT, PS/2 and PC-DOS are trademarks of International
- Business Machines Inc.
- - MS-DOS is a registered trademark of Microsoft Corporation.
- - All other brand and product names are trademarks or registered
- trademarks of their respective holders.
-
-
- 1.10 Hydra in other software (also FidoNet mailers!)
-
- It's simple, nag the author of that software and give him this package
- with all the information. There is not a single reason for the
- developer in question not to integrate the Hydra protocol in his/her
- software. It will even add to its value. And if they don't do it now,
- they'll have to later after the competition has done it...
- A number of FidoNet technology mailers offer Hydra as their primary
- protocol. Please refer to the HYDRA specifications for detailed
- information about HYDRA in FTS-0006 (YooHoo) and EMSI mailsessions.
-
-
- 1.11 Other environments/operating systems
-
- Ports of a Hydra source (or a new implementation) to other platforms
- and operating systems are strongly encouraged. Because of the
- protocol's extreme flexibility Hydra may run on machines with the most
- severe restrictions where other protocols could never work.
- Please send us a note if you've implemented or ported Hydra, so we can
- keep track of its progress accross the different platforms in
- cyberspace. If you can send us sources or executables, even better.
- We will try to maintain a library of all this stuff.
-
-
-
-
-
-
-
-
-
-
-
-
-
- HydraCom Page 5
-
-
-
- Page 6 HydraCom
-
- 1.12 Where to send your spare funds
-
- The HydraCom executable and full sourcecode have been made available
- free of charge in order to aid rapid distribution, acceptance and
- integration of this new protocol in existing and new libraries,
- terminal, BBS and other software, and the like.
- However, a donation recognizing my work would be very much
- appreciated, especially if you are making money of it yourself.
- Such donations will be used specifically on small practical
- datacommunications projects and investments in Eastern Europe I am
- involved in, at this moment particularly in Lithuania.
- Unless you don't want it, your name will be listed in a support file.
- If you contact me at the address below before sending a donation, I
- may be able to provide you with an address or account number in your
- vicinity rather than having you waste time, effort and money on
- international transfers.
- Any donation, however small, will thus be used purposefully for the
- good of communications in general.
- If because of Hydra you are making a lot of money off your Bulletin
- Board, library, software or distribution business, you may want to
- consider a larger or periodical donation.
- Thanks for your support! Arjen Lentz.
-
-
- 1.13 Support and contact addresses
-
- This software being free, there is no real support it. However, I will
- try to help you solving any problems if you ask nicely, and perhaps
- other users can be of assistance too.
- In FidoNet a HYDRA conference may be available near you for discussing
- the protocol and its implementations.
-
- Hydra and HydraCom were designed and written by:
-
- Arjen G. Lentz, LENTZ SOFTWARE-DEVELOPMENT
- Langegracht 7B, 3811 BT Amersfoort, The Netherlands
- AINEX-BBS +31-33-633916 (V.32BIS/V.42BIS/HST14k4)
- FidoNet node 2:283/512 (Arjen Lentz)
- Internet: arjen_lentz@f512.n283.z2.fidonet.org
-
- Hydra was designed in cooperation with:
-
- Joaquim H. Homrighausen
- 389, route d'Arlon
- L-8011 Strassen
- Luxembourg
- FidoNet 2:270/17
- joho@ae.lu
-
-
-
-
-
-
-
-
- Page 6 HydraCom
-
-
-
- HydraCom Page 7
-
- 2 Description of specific features
-
-
- 2.1 Split screen chat during a Hydra session
-
- During a Hydra transfer you can chat with someone on the other side,
- and without that dreaded line noise! Just like all other packets, chat
- data is protected by CRC-32 and retransmitted when it doesn't come
- accross unscaved.
- Once a Hydra session is past the init state, you can start chat chat
- mode on your side by pressing Alt-C. A message is sent to the remote
- informing about this fact. You type in the bottom window, and any text
- from the remote appears in the upper window (split screen). Meanwhile
- you can still keep track of the file transfer progress at the op of
- the screen.
- The chat option does not effect protocol reliability. A Hydra session
- is prolonged even after all files have been sent/received, but only so
- long as both sides are active in chat mode. If one side quits, the
- session is then immediately finished.
- You can end chat mode on your side by pressing Alt-C again.
- If you type nothing in 60 seconds, chat mode is automatically ended.
- Hydra will inform you in your local window at what point it iss
- possible to start a chat mode. Similarly, informative messages about
- the chat facilities on the other side will appear in your remote
- window.
- During file transfer, chat text will appear in chunks. A smooth chat
- would serously degrade performance of the file transfers!
- Bulletin Board sysops may want to disable the bell noise of the chat
- facility with the 'nobell' option. Chat will still be available then,
- but without unwanted noise from the remote.
-
-
- 2.2 Resuming aborted transfers
-
- HydraCom does not allow such uncompleted files to float around on your
- disk, but rather renames the file to a unique file name and keeps a
- log with the original file-information of all interrupted transfers in
- that directory; this is an especially useful feature for BBS, because
- you can now enable bad-transfer recovery on upload without having to
- keep track of incomplete files. And for users it saves time because
- they do not have to transfer the complete file allover again, but only
- the part which was not yet transferred.
- This feature may be disabled with the 'noresume' option.
-
-
- 2.3 Networks and Multitaskers
-
- HydraCom opens files in shared mode so that it may be used in a
- multiline environment on LANs and under multitaskers such as DESQview.
- You just need to make sure any control files have different names
- (correct task number, in case of the Opus-interface).
-
-
-
-
-
- HydraCom Page 7
-
-
-
- Page 8 HydraCom
-
- 2.4 Using a FOSSIL driver
-
- In addition to the internal serial communication routines the program
- can also make use of the popular FOSSIL interface, which enables less-
- compatible MS-DOS machines to run the same software without special
- modifications, just after loading another FOSSIL driver designed for
- that machine.
- The internal communication routines automatically detect and use FIFOs
- in the the 16550 UART, providing better throughput at high speed. A
- 16550 also decreases the chance of bytes getting lost (overrun).
- Also on some fully compatible machines a FOSSIL driver may give better
- results than the internal routines. Most BBS and point systems will
- usually already have a FOSSIL driver resident.
- For best results, set the FOSSIL receive and transmit buffers to at
- least 4KB (4096 bytes). HydraCom will complain if either or both are
- smaller, but the program will still function. Smaller buffers may
- cause more CPU time to be used, a lower transfer performance, and
- bytes may be lost causing transmission errors.
-
-
- 2.5 Using a Video FOSSIL
-
- The distributed executable HydraCom.EXE uses a windowing library which
- features fast direct screen access (DESQview aware), internal extended
- ANSI/VT-100 emulation for the terminal, and the capability to use a
- Video FOSSIL (like the VFOS_IBM/VFOS_BIO BinkleyTerm screen drivers by
- Bob Hartman).
- If you use a Video FOSSIL with HydraCom, make sure you have very
- recent version! Old versions of VFOS_IBM and VFOS_BIO have a bug in a
- couple of functions that the windowing library uses. BinkleyTerm does
- not use these functions, so you may not have noticed this problem
- before. Contact me for patched versions, or the corrected Video FOSSIL
- source files.
- All information HAS been forwarded to Bob Hartman.
-
- Note: when compiling the HydraCom sources yourself without
- modification, console I/O functions are used because the windowing
- library is not freely available. Contact me if you are interested in
- purchasing this library anyway (includes the complete sources in C and
- inline assembler).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Page 8 HydraCom
-
-
-
- HydraCom Page 9
-
- 2.6 AutoStart Hydra transfers
-
- A Hydra session can be started automatically upon receipt of a special
- AutoStart sequence:
-
- ASCII: 24 99 65 92 102 53 92 97 51 24 97
- Chars: Ctrl-X c A \ f 5 \ a 3 Ctrl-X a
-
- This is the Hydra START packet, which is always hex-encoded for clear
- passage through even the most restricted links.
- Before the START packet Hydra also transmits the letters 'hydra' in
- lowercase followed by a CR (ASCII 13), to start the Hydra protocol
- from for instance a Unix command line.
- To be certain the string is detected, strip the 8th bit of all
- incoming bytes and then ignore all ASCII characters 0-31 and 127
- except ASCII 24 before comparing it to the next character in the
- autostart string.
-
-
- 2.7 Aborting a Hydra transfer
-
- A Hydra session may be aborted at any moment by pressing the Escape
- key.
- When your end is not engaged in a Hydra session but the other side is,
- typing at least 5 consequtive Ctrl-X will abort the remote Hydra.
-
-
- 2.8 Configuration utility HydraCfg
-
- To create and edit the default configuration of HydraCom, a utility
- HydraCfg is provided where all options and settings can be changed and
- checked in a user friendly full screen windowed environment.
- If a mouse driver is present, it may be used to move the cursor around
- and select options.
-
- When HydraCfg is called without commandline parameters, it searches
- for HydraCom.EXE first in the current then in all the directories
- listed in the DOS PATH. If found, and a file HydraCom.CFG is also
- present in that directory, that is the file that will be read and
- edited. If HydraCom.CFG doesn't yet exist, HydraCfg asks if you want
- to create it.
- If HydraCom.EXE is not found, a HydraCom.CFG may be created/edited in
- the current directory.
- You may also specify a full path/filename of a HydraCom.CFG style file
- on the HydraCfg command line, in which case no search is done.
- See the section about the default configuration file for more
- information.
- HydraCfg can provide additional information about options on the
- bottom line of the screen, if the file HydraCfg.HTX (helptext) is
- present in the same directory where HydraCom.EXE is located.
-
-
-
-
-
-
- HydraCom Page 9
-
-
-
- Page 10 HydraCom
-
- 2.9 Reliability
-
- A remote machine may crash, jump out of a batch file or otherwise die
- on you while you are on-line. Hydra maintains a special braindead
- timer, aborting a session when there has been no REAL progress for two
- minutes.
- This may save you a lot of money when using Hydra in an automated
- environment, especially on international phonecalls!
- Other protocols have been known to keep a transatlantic line open for
- more than 6 hours with nothing happening.... big auch.
-
- The Hydra protocol has been designed in such a way that deadlocks or
- misunderstandings between the two sides cannot occur.
-
- Hydra is extremely tolerant towards network and satellite delays.
-
- If Hydra reports a 'timeout' or 'retry', this does not necessarily
- mean something terrible is happening. The protocol has a different
- design and therefore behaves differently from what you will be used
- to.
- If things go really wrong the transfer will be aborted anyway so there
- is no need to worry, the messages are just so you have some
- information about what is going on.
- For example, Hydra sometimes re-transmits a packet after a number of
- seconds, just in case the other side has missed it previously. Because
- of line delay the acknowledgement to the original packet may already
- be under way. In this case the duplicate packet is ignored, so the
- transfer is not delayed. If a packet does get lost, this alternative
- tactic speeds up recovery.
-
-
- 2.10 Protocol performance
-
- Contrary to the hype surrounding other protocols, Hydra does not
- pretend to be the fastest file transfer protocol in cyberspace.
- In general it is about as fast as the other top protocols, giving you
- a choice on grounds of reliability and versatility rather than
- outragious claims.
-
- Every protocol has a certain amount of overhead because of error
- detection and other facilities; this overhead has of course been
- minimized, but Hydra will not provide the user with options to
- increase performance in such a way that reliability is affected.
- This is what other protocols sometimes do, and often don't tell the
- user about it (nor of the consequences). Even so called 'errorfree
- connections' such as MNP and V.42 links are NOT 100% errorfree. Some
- errors slip through, and sometimes a byte gets lost or mangled between
- the modem and the computer or the communications routines.
- And to be fair, the actual gain in performance is always minimal; in
- rounded percentage terms it sounds appealing but in effect most claims
- amount to no more than about 10 seconds on a transfer of more than 10
- minutes. Hardly worth it, wouldn't you agree?
-
-
-
-
- Page 10 HydraCom
-
-
-
- HydraCom Page 11
-
- Some other bidirectional protocols add up the performance of the two
- directions, of course giving nice figures when comparing to
- unidirectional protocols. But this is really unfair.
- Hydra reports separate figures for each file transfered, and stays on
- the conservative side. You should not trust the performance ratings
- for transfers which last less than a minute!
-
- Okay.. you don't have to believe all this: ignore the numbers reported
- by the various protocols, and time a transfer yourself.
- Make sure you use a file large enough for at least 5 to 10 minutes
- transfertime, otherwise the results will not be reliable for
- comparison.
- And watch the behaviour of a protocol on for instance a bad
- connection; will it choke and abort or handle the situation well?
-
-
- 2.11 HST and other half-duplex links
-
- Hydra can also handle HST and similar links that have one high-speed
- channel and only a low-speed backchannel. Simultanous bidirectional
- transfer is not effective in this case, causing continuous line
- turnarounds and slowing down transmission dramatically.
- If you are a user, want call a BBS at HST speed, and upload and
- download in the same session, use the 'nooriginator' and 'hdxlink'
- options together. HydraCom will then first receive all files, then
- transmit.
- If you set the options even for other real full duplex connections
- like V.22(BIS) and V.32(BIS), HydraCom will not use its bidirectional
- capability then either. So use this only when required by the specific
- modem connect.
- In practise, it is easier if you just upload and download in a
- seperate Hydra session if you have an HST connect. Then there is no
- need to use these options at all.
- Bulletin Board sysops should NEVER set these options at all!
- The Hydra protocol is protected against deadlock; if both sides are in
- one-way transfer mode, this will be detected and one-way mode switched
- off.
- Of course, if you can choose between for instance an HST and a real
- full duplex connect, the choice is easy... full duplex every time!
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- HydraCom Page 11
-
-
-
- Page 12 HydraCom
-
- 3 Commands and Options
-
- Usage:
- HydraCom [port N] [speed N] [<options> ...] <command> [<parms> ...]
-
- General:
- options:
- port N Comport [1..16] (default COM1)
- speed N Com-speed [300..57600] (default current speed)
- line N Actual line speed (use 'speed' to set comport)
- parity Set 7E1 instead of 8N1 (forces option highbit)
- dropdtr Drop DTR if carrier is lost
- nocarrier Disable carrier detection
- noinit Don't init/deinit FOSSIL driver
- handshake <flg> Enable soft (XON/XOFF), hard (RTS/CTS) or both
- log <file> Logfile to log the goings on
- level N Level of logging, 0=max, 6=min (default=2)
- result <file> Log transfer info to DSZ compatible logfile
- noresume Disable receive bad-transfer recovery
- nostamp Don't stamp with original but current filetime
- receive <path> Path to store any received files
- nobell Disable bell noise in Hydra session chat feature
- link options:
- mailer Mailer mode, used by Dutchie (see documentation)
- nooriginator Not originator, fallback to one-way transfer
- allowed
- hdxlink Force one-way transfer mode (only with
- nooriginator)
- xwindow N Transmitter window size (default 0=full streaming)
- rxwindow N Receiver window size (default 0=full streaming)
- option xonxoff Escape/strip XON/XOFF characters
- option telenet Escape/strip Telenet escape
- option ctlchrs Escape/strip ASCII 0-31 and 127
- option highctl Apply above three also for 8th bit
- option highbit Encode for 7 bit, strip 8th bit
- commands:
- send [<fspec> ...] Send <fspec>/@<ctlfile>/nothing + receive
- get [<path>[<name>]] Only get file(s), if name is specified, get
- first file (name override) and skip all
- others
- term Small terminal + send & AutoStart
- capability
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Page 12 HydraCom
-
-
-
- HydraCom Page 13
-
- 3.1 Options
-
- An option modifies the default settings of HydraCom, like the
- communications port number and speed of the communications port.
- Each option consists of a keyword, sometimes followed by a string or
- number. Keywords may be abbreviated to their first three letters.
- For example: POR 2 means that HydraCom should use com port 2.
- This is not true for any parameters following an option, these should
- all be fully spelled out.
- Case is not important. Invalid options and parameters are ignored.
-
-
- 3.1.1 port N
-
- Select the comport HydraCom will use, in the range of 1 to 16. The
- default value is COM1. The internal communication routines can only
- handle port COM1 to COM4 (3F8/IRQ4, 2F8/IRQ3, 3E8/IRQ4, 2E8/IRQ3).
-
-
- 3.1.2 speed N
-
- When using a FOSSIL driver, valid communication speeds are 300, 1200,
- 2400, 4800, 9600, 19200 and 38400 bits per second. With the internal
- async routines, any speed between 300 and 57600 BPS may be given.
- If the SPEED option is not specified, HydraCom will use the current
- speed of the port. Locking of the speed should be done in the FOSSIL
- setup, not in HydraCom.
- If the FOSSIL is locked the speed statement does not have any effect.
-
-
- 3.1.3 line N
-
- For high-speed modems, the SPEED option determines the speed of the
- comport while LINE determines the speed that will used for efficiency
- calculations, data packet size and timeouts.
- It is absolutely vital that HydraCom knows what speed the line has,
- and the program has no way of knowing unless you inform it!
- If the FOSSIL is not locked and the speed option is present, the line
- option need not be specified as well.
- The thresholds for data packet size and timeouts are at 1200, 2400,
- and 4800 bps. Ie. if speed is set to 38400 but the actual link speed
- is 14400, there's no need to use the line option as for HydraCom there
- is no practical difference between 14400 and 38400 when calculating
- the necessary figures.
- But if the comport is locked at 9600 or 38400 and the line speed is
- 2400 or even lower, you'll have problems if you don't specify the
- correct line speed here.
-
-
-
-
-
-
-
-
-
- HydraCom Page 13
-
-
-
- Page 14 HydraCom
-
- 3.1.4 parity
-
- The parity option selects 7 databits, even parity (7E1) instead of the
- default 8 databits no parity (8N1), also forcing 'option highbit' so
- the Hydra protocol makes the necessary arrangements for a 7-bit
- connection.
-
-
- 3.1.5 dropdtr
-
- This option will probably only be useful for BBS with modems set to
- auto-answer. If specified, HydraCom will lower the DTR (Data Terminal
- Ready) line on the serial port. For HAYES-compatible modems with a
- set-up of S0=1 or something similar, this will cause the modem NOT to
- answer the phone while the DTR remains low. The BBS then has time to
- recycle and raise the DTR again when ready for the next call.
-
-
- 3.1.6 nocarrier
-
- Mostly of use with certain null-modem cables or stand-alone operations
- within the HydraCom terminal function, this option configures HydraCom
- so it will not check the DCD (Data Carrier Detect) line on the serial
- port. Normally, HydraCom will abort upon loss of carrier.
-
-
- 3.1.7 noinit
-
- Do not initialise the FOSSIL on startup. Running under some software
- like the mailer program Dutchie, HydraCom is not required nor supposed
- to initialise the resident FOSSIL driver. This option will make sure
- HydraCom will refrain from attempts at initialisation.
-
-
- 3.1.8 handshake <flg>
-
- This option allows the enabling of various types of flow control.
- SOFT enables xon/xoff handshaking, HARD enables rts/cts handshaking,
- and BOTH obviously enables both software and hardware flow control.
- FOSSIL drivers force RTS/CTS handshaking for a locked communications
- port.
- The internal communications routines (ie. the one used when there is
- no FOSSIL driver present) do not support XON/XOFF handshaking, nor do
- they apply RTS flow control (modem->computer). CTS flow (computer-
- >modem) is supported.
- Setting software flow control automatically forces on 'option xonxoff'
- to make sure Hydra escapes these characters in its packets.
-
-
- 3.1.9 log <file>
-
- If specified, HydraCom will log messages to this file as well as
- printing them on the screen. The output is similar to the format used
- by programs like Dutchie, The-Box, BinkleyTerm, Opus and Maximus.
-
-
- Page 14 HydraCom
-
-
-
- HydraCom Page 15
-
-
-
- 3.1.10 level <loglevel>
-
- This option is only really useful if LOG is also specified. Loglevel
- may be anything from 0 to 6. Level 0 logs anything up to Hydra packet
- control data. Level 6 logs only severe or fatal errors. The default
- loglevel is 2.
-
-
- 3.1.11 result <filename> (DSZ logfile)
-
- This option will create or append a DSZ (by Omen Technology)
- compatible log file, which some programs (such as the RBBS-PC or XBBS
- BBS) use to determine the outcome of a transfer.
- The format is as follows:
-
- <res> <byts> <bps> bps <cps> cps <err> errors <flow> <last> <fname>
- <sn>
-
- <res> H = file is sent, R = file is received.
- <byts> Actual number of bytes transferred.
- <bps> Line communication speed in bits per second.
- <cps> Protocol performance in characters per second. For very
- short transfers a rating of 9999 cps is given.
- <flow> Number of transmission errors occurred (0).
- <err> Number of flow control stoppages (0).
- <last> Size which was used for the last block in the transfer
- (1024).
- <fname> Full path and file name.
- <sn> Serial number of the program on the other side (0).
-
- HydraCom will not write a result line for aborted transfers, but the
- result file itself will always be created (empty).
-
- Prior to processing any other options the DSZLOG environment variable
- is checked and (if present) copied to the RESULT option file name.
-
-
- 3.1.12 noresume
-
- By default, HydraCom uses an internal mechanism to keep track of
- interrupted transfers: It keeps unfinished received files BAD-XFER.???
- where ??? is a counter from 000 to 999 used to create a unique file
- name. The original file name, date/time and size of the file are
- logged to a file called BAD-XFER.LOG. Both files reside in the
- directory where files are received. With NORESUME, HydraCom will not
- keep/log unfinished downloads but instead deletes the partial file.
-
-
-
-
-
-
-
-
- HydraCom Page 15
-
-
-
- Page 16 HydraCom
-
- 3.1.13 nostamp
-
- Don't retain the original file date/time information which was
- transmitted, but stamp received files with the current date/time.
- Some BBS software requires this to be able to scan for new files.
-
-
- 3.1.14 receive <path>
-
- Files received through HydraCom will be stored in directory <path> if
- this option is used. Otherwise files will accumulate in the current
- directory.
-
-
- 3.1.15 nobell
-
- Normally, the BEL character (Ctrl-G) will cause the remote system to
- give a short beep. This may not be desired if HydraCom is for instance
- used under a BBS, so with this option you can disable the beep. It
- only applies to the chat mode during a Hydra tranfer session.
-
-
- 3.1.16 mailer
-
- Selects mailer mode, changing HydraCom's behaviour slightly as
- required by the Dutchie mailer which uses it as an external protocol
- for FidoNet technology mail sessions.
-
-
- 3.1.17 nooriginator
-
- Instructs HydraCom to NOT act as the 'originator' side in case of
- trouble during a transfer. The 'answer' side will switch to one-way
- transfer mode under certain conditions (equivalent to the hdxlink
- option).
- Normally you won't need this option yourself, its main use is for
- programs like Dutchie in combination with the 'mailer' and 'hdxlink'
- options.
- Refer to the section about HST and other half-duplex modems earlier in
- this document for a more complete description of these options.
-
-
- 3.1.18 hdxlink
-
- Forces one-way transfer mode (half duplex Hydra, disables bi-
- directional transfers). This option only works if nooriginator is
- enabled as well. This option is meant for use on HST and similar
- asymmetrical connections. Refer to the section about the
- 'nooriginator' option above for more information.
-
-
-
-
-
-
-
- Page 16 HydraCom
-
-
-
- HydraCom Page 17
-
- 3.1.19 txwindow N
-
- The number of bytes to send before remote acknowledgement of reception
- should be received. If it's set to 0 (default) HydraCom won't wait for
- acks and use continuous streaming.
- In severe situations, this option may be necessary for links via
- packet switched networks and sattelites to prevent runahaid (windowed
- streaming).
- Primarily, this option is used when the machine on the other side
- cannot handle simultanous serial and disk I/O (segmented streaming).
- The exact receive and transmit window sizes are negotiated
- individually by the two sides at the start of a Hydra session, so if
- the other side has set a more limited value, that is the window size
- that will be used for that direction.
-
-
- 3.1.20 rxwindow N
-
- The number of bytes to receive before acknowledgement (ACK) should be
- returned to the sender (default 0=none). Refer to the description of
- the 'txwindow' option above for more information about windowed
- transmission.
-
-
- 3.1.21 link options
-
- Link options are used to send data over nondefault lines (such as 7-
- bit links, and such). Hydra will encode all data to a suitable format,
- send it, and the receptor will decode the data back to it's original
- format.
- option xonxoff Escape/strip XON/XOFF characters. (ASCII 17 and 19)
- option telenet Escape/strip telenet escape sequence CR-@-CR (ASCII
- 13,64,13)
- option ctlchrs Escape/strip ASCII characters 0 to 31 and 127.
- option highctl Makes xonxoff/telenet/ctlchrs also escape/strip their
- respective characters if the high bit.
- option highbit Encode for 7 bit transfers. (encodes 8 bit to 7 bit)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- HydraCom Page 17
-
-
-
- Page 18 HydraCom
-
- 3.2 Commands
-
- HydraCom expects a command at the end of the command line (ie after
- all options). There are three possible commands: send, get and term.
- Send is for sending files, get is to just receive files without
- sending any, and term is the mini terminal.
- All commands normally abort upon loss of carrier unless the
- 'NOCarrier' option is used.
-
-
- 3.2.1 send [<filespec> ...] [@<ctlfile> ...]
-
- The send command causes HydraCom to send <filespec.ext>.
- If no file specification is given, this command will just act like a
- get and just receive files.
-
- @<listname.ext> will cause HydraCom to read a file called
- <listname.ext> in [<drive:\path>] and send the files specified in that
- text file. Each entry in that file should be placed on one line eg,
- when you want to send TEST.*, NEWHYD?.ARJ and PAL_112.C, you could
- place them in SEND.TXT, which could contain:
- C:\MAIL\FILE\TEST.*
- C:\DOCS\NEWHYD?.ARJ
- E:\C\DEVLP\PAL_112.C
-
- Normal file specifications and multiple @ctlfiles may be used on one
- commandline, and you can specify paths and the usual DOS wildcards *
- and ? (which are expanded to the file names which match the
- specification).
-
- In @ctlfiles aliasing and transfer options may be used.
- Aliasing means that HydraCom will send a file with an alias name,
- specified after that name, so if your @-file contain a line
- C:\DOCS\ANY.TXT 01A551FC.A0D
- then HydraCom will send the file ANY.TXT as 01A551FC.A0D.
- A '#' sign as the first character on a line will cause HydraCom to
- truncate the file(s) to zero length after succesful transfer. A caret
- (^) tells HydraCom to delete that file after it has been sent.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Page 18 HydraCom
-
-
-
- HydraCom Page 19
-
- 3.2.2 get [<path>[<name>]]
-
- The get command may be used if there are no files to be sent, just
- received.
- With no parameter, get will put received files into either the current
- directory or the directory specified in the 'receive' option.
- If a path specification follows the get command, this overrides the
- 'receive' option. A get path specification MUST have a trailing
- backslash!
- If a filename specified, HydraCom will receive just one file, store it
- with the specified name, and refuse any other files the remote wants
- to send. This 'feature' is provided because some software cannot
- handle batch uploads and wants to know the name of the single file
- before the transfer.
-
-
- 3.2.3 term
-
- This activates HydraCom little built-in dumb terminal.
- HCOM_DOS has ANSI emulation if you have ANSI.SYS loaded; HCOM_GEN has
- an extended ANSI/VT-100 emulator in its windowing library.
- Downloading in the HydraCom terminal is fully automatic, HydraCom
- detects the remote has intiated a Hydra session (AutoStart). Any files
- in the upload queue will also be transmitted.
-
- There are several options and commands in the terminal mode:
-
- PgUp: Enter/edit file upload queue; HydraCom asks for file
- specification(s), wildcards are allowed. You may NOT specify a
- @ctlfile. No upload is started with this command, the specified
- files will be sent when either the remote initiates a session
- or when you press PgDn.
- PgDn: Download; HydraCom initiates a Hydra session and waits for
- incoming files/packets. Any files selected with PgUp will be
- sent. You cannot select files for download within HydraCom, you
- must do this within the BBS you're calling; ie. you can not
- just 'request' files from the remote during a Hydra session.
- Alt-X: Exit the terminal and HydraCom.
- Alt-C: Clears the screen and puts the cursor in the upper left corner.
- Alt-H: Hangup (on hook), this command drops the DTR line and causes an
- immediate log-off (BBS do have a G)oodbye command.. use it!).
- Alt-E: Toggle duplex, this command toggles the local echo mode.
- Alt-B: Toggle stripping the 8th bit of all incoming characters. This
- toggle is forced on if the 'parity' commandline option has been
- specified.
-
-
-
-
-
-
-
-
-
-
-
- HydraCom Page 19
-
-
-
- Page 20 HydraCom
-
- 3.3 Default configuration file
-
- At start-up, HydraCom will check whether a file named <exename>.CFG
- exists in the directory where the HydraCom executable resides, and if
- it does, scan it for options. This is always done first, regardless of
- what interface method is used to pass other commands and options. By
- <exename>.CFG we mean that, if for instance the HydraCom executable is
- named HydraCom.EXE, the name of the configuration file checked for
- would be HydraCom.CFG. C:\WORK\HC.EXE will search for C:\WORK\HC.CFG.
- Each line in the configuration file may contain an option and possible
- parameters. Everything after a semicolon (;) will be ignored
- (comments).
-
- ;----------[ sample terminal configuration file ]----------
- port 2
- speed 38400
- receive c:\comms\download\
- nocarrier
- log c:\bbs\hydracom.log
- level 4
-
- The configuration file may not contain a command (send, get or term).
- Statements on the command-line override those in the configuration
- file.
-
- You can use the utility HydraCfg to create and edit a default
- configuration file for HydraCom in a more userfriendly environment
- (full-screen windowed, mouse support, information and help texts).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Page 20 HydraCom
-
-
-
- HydraCom Page 21
-
- 4 Using HydraCom as an external protocol
-
- HydraCom can be used within a lot of, if not all, communication
- programs which support intelligent DOS access like errorlevels,
- shelling to batch files, spawning, etc. Most programs have external
- protocol support themselves, but HydraCom can also work with programs
- which can use only external view or edit programs. In that case you
- can call exactly the same batch file as described for Procomm Plus.
- You could for example put the upload batch file instead of a view
- utility and fill in the download batch file instead of the editor
- utility. When you are asked what file to view, you'd fill in the
- filename(s) to be uploaded.
-
-
- 4.1 Interface methods
-
-
- 4.1.1 Opus-style external protocol interface
-
- HydraCom can operate as an Opus external protocol driver, as used in
- the Opus bulletin board system and various mailer, BBS and terminal
- packages which utilize the Opus method of calling external protocol
- drivers.
-
- Upon exit to the external protocol writes an Opus-style control file,
- the name of which depends on the file name of the executable HydraCom.
- If, in your case, HydraCom is called HydraCom.EXE, then Opus will
- write a file called HydraCom.CTL to the drive/path where HydraCom.EXE
- resides, from which HydraCom will read all necessary information about
- the transfer.
- Hydra will create a special Opus-format logfile HydraCom.LOG (in the
- same directory where HydraCom.CTL was stored) which provides the BBS
- software with a list of files that were sent/received.
-
- The Opus 1.0x method is quite similar to the way Opus 1.10 and later
- versions call external file transfer protocols. HydraCom handles both
- methods. The Opus-protocol interface mechanism is automatically used
- if a .CTL control file is found. If a task number (-tN where N is the
- task number) is specified on the HydraCom commandline, the new method
- is used which merges a task number into the filename of the control
- and log files for multi-line operation. A control file for task 3 when
- calling HydraCom.EXE would be named HydraC03.CTL.
- Note: any commandline parameters after the -tN option are ignored,
- HydraCom immediately proceeds with processing the .CTL file.
-
-
-
-
-
-
-
-
-
-
-
-
- HydraCom Page 21
-
-
-
- Page 22 HydraCom
-
- HydraCom uses the -pN (port number, 0 based) and -bN (speed) from the
- commandline, other Opus-style parameters are ignored.
- In the .CTL file the following Opus-style options and commands are
- used and fully implemented in HydraCom:
-
- port Com port, identical to the 'port' commandline option.
- baud Com speed, like the 'speed' commandline option.
- modem Extended modem information like real line speed, handshake
- options, carrier mask.
- log Log file, identical to the 'log' commandline option.
- upload Where received files are to be stored; like the 'receive'
- commandline option.
- send Specification of file(s) to be sent; DOS wildcards are
- allowed, as well as the special transfer options. If the
- file specification is preceded by a # character, the
- specified files will be truncated to zero-length after
- successful transmission. A ^ character has the files
- deleted after successful transmission. If another name is
- specified on the same line (no path), this name is given to
- the remote instead of the real name (aliasing).
- get As Hydra is a full duplex protocol, this command is
- completely ignored. A receive path should be specified
- using the 'upload' or 'receive' option.
-
- Other (unknown to HydraCom) Opus-style commands are just ignored.
- All HydraCom commandline options (not commands!) be also be present in
- a .CTL file.
- Take care that all options are listed in the .CTL before the first
- 'send' line, otherwise those options will not have been read yet.
-
-
- 4.1.2 DSZ-style external protocol interface
-
- HydraCom can be called by any program using the DSZ style of passing
- options/commands; of course the options and commands differ from DSZ,
- but the basic mechanism is the same with support for @ctlfiles and
- usage of the DSZLOG environment variable. For more information on the
- format of the DSZ result logfile, see the section about the 'result'
- option.
-
-
- 4.1.3 Exit codes (errorlevels)
-
- Some programs check error codes to decide whether a transfer has been
- completed successfully or not. HydraCom uses the following
- errorlevels:
-
- 0 Normal termination
- 1 Transfer aborted, carrier lost, etc.
- 255 System error: not enough memory, etc.
-
-
-
-
-
-
- Page 22 HydraCom
-
-
-
- HydraCom Page 23
-
- 4.2 Using HydraCom with terminal programs
-
-
- 4.2.1 Telix
-
- Telix 3.15 supports up to 4 external protocols, 3.20 supports 5.
- You need to create a single batchfile (HYDRAUP.BAT) with one line:
-
- HYDRACOM port %2 speed %1 uploads D:\DL\ send %3 %4 %5 %6 %7 %8 %9
- (change D:\DL\ to the path of your own download directory)
-
- Start Telix, and from the main terminal window press Alt-O (Configure
- Telix), select option P (Protocol options) and select a free protocol
- line (A-D/E) (or replace an unused protocol):
-
- Key H
- Protocol name Hydra
- Upload filename HYDRAUP
- Download filename HYDRAUP
- BAT or script Batch
- DL name NO
- Autodownload string (press ctrl-X)cA\f5\
- (autodownload string only available in Telix 3.20)
-
- Now press ENTER (returns to configure Telix) and select option W
- (Write setup to disk). Telix will automatically return to the main
- terminal window.
-
-
- 4.2.2 Communique
-
- HydraCom batchfile that can be used for Communique:
-
- @echo off
- rem HydraCom installation under Communique 1.0x
- rem -------------------------------------------
- rem Name : Hydra
- rem Key : 1
- rem Upload : CU_Hydra.BAT *C *B *D *U *G
- rem Download: CU_Hydra.BAT *C *B *D *U
- cls
- HydraCom port %1 speed %2 nocarrier handshake receive %3 send %5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- HydraCom Page 23
-
-
-
- Page 24 HydraCom
-
- 4.2.3 Commo
-
- Add the following to your COMMO.MAC file in the appropriate places:
-
- (the upload protocol menu)
- HydraCom using HYDRACOM.EXE {goto phyd}
- (the download protocol menu)
- HydraCom using HYDRACOM.EXE {goto phyd}
- (no download macro, just uses uploade macro)
- (upload macros)
- HydraCom {:phyd} {call gfnu}
- {exec-a HYDRACOM por %_por spe %_spe han
- hard rec %uldir sen %file} {} HYDRACOM.EXE
-
- And the following line to your COMMO.SET file:
- {aut=phyd,^XcA\f5\a3^Xa} Auto Receive, HydraCom
-
-
- 4.2.4 Procomm Plus
-
- This has been tried and found to work with the Procomm+ TestDrive
- version. For use with Procomm Plus, you need to create one batch file
- which calls HydraCom:
-
- HydraCom port 1 line 2400 receive D:\DL\ send %1 %2 %3 %4 %5 %6
- (change D:\DL\ to the path of your own download directory)
-
- Procomm+ does not provide the line speed, comport number or the path
- to store received files; you should fill them in yourself.
- It's not terribly user-friendly and it may cause you trouble. But
- there's not much you can do about it except get different terminal
- software.
-
- You should specify the batch file in the Procomm Plus protocol set-up
- menu. From the Procomm Plus main menu, press Alt-S (Setup Utility),
- then choose PROTOCOL OPTIONS and take an empty pair of entries, either
- A-B, C-D or E-F, if you would choose A-B, then press A, fill in the
- HydraCom upload batchfilename (HPCU) without extention, and press
- ENTER. Then press B, fill in HPCD and press ENTER. Then press escape,
- select the SAVE SETUP option, and press escape again.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Page 24 HydraCom
-
-
-
- HydraCom Page 25
-
- 4.2.5 TeleMate
-
- Create a batchfile, to be placed in the TM home directory:
-
- HydraCom.EXE port %2 speed %1 receive D:\DL\ send %3
- (change D:\DL\ to the path of your own download directory)
-
- Now start TeleMate and from within the TeleMate main terminal window,
- press Alt-O (Options).
- Select option P (Protocol). Select a free protocol line, or replace an
- unused protocol:
-
- Name Hydra
- Key H
- Upload batch HYDRAUP
- Download batch HYDRAUP
- Prompt for dl name NO
-
-
- Exit the protocol window with the OK selection (returns to 'Options'
- window), select option S (Save options) and press ESC (back to main
- terminal window).
-
-
- 4.2.6 Boyan
-
- To use HydraCom with this program, run Boyan and press Atl-C
- (Configure BOYAN) from the main terminal window. After this, select
- option D (Disk, directory, files) and then option H (Path for external
- protocols)
- Now enter the drive and path where HydraCom.EXE can be found, don't
- forget the trailing backslash '\'. Then press ENTER (finish entry).
- Press ESC (returns to 'configure BOYAN' screen), select option X
- (External transfer protocols) and select a free protocol line entry
- (0-9).
-
- Protocol name Hydra
- Menu letter H
- External file HydraCom
- Prompt for DL-name? NO
- Upload \DC-[%P:HydraCom port %MD speed %MS rec dl>\ send %TF]
- Download \DC-[%P:HydraCom port %MD speed %MS rec dl>\ get]
-
- (Don't forget to specify the downloadpath including the trailing '\')
- Press ENTER (finish entry). Then press ESC (returns to 'configure
- BOYAN' screen) and, again, press ESC (back to main terminal window)
-
-
-
-
-
-
-
-
-
-
- HydraCom Page 25
-
-
-
- Page 26 HydraCom
-
- 4.2.7 Qmodem
-
- To use HydraCom with the Qmodem communications package, enter Qmodem,
- and from the main terminal window, press Alt-N (Configure Qmodem) Then
- select option P (Protocols) and select a free protocol line entry
- (0-9).
-
- Select character H
- Protocol Hydra
- Upload BAT HYDRAUP.BAT
- Download BAT HYDRAUP.BAT
- Filename Prompt N
-
- Finished? press ESC (returns to 'Protocols' window) and again, press
- ESC (returns to 'Configure Qmodem' window), select option E (Exit) and
- select option S (Save Changes) Qmodem will then automatically return
- to the main terminal window.
-
- The batchfile (placed in the Qmodem home directory):
-
- HydraCom port %2 speed %1 receive D:\DL\ send %3 %4 %5 %6 %7 %8 %9
- (change D:\DL\ to the path of your own download directory)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Page 26 HydraCom
-
-
-
- HydraCom Page 27
-
- 4.3 Using HydraCom with BBS software
-
-
- 4.3.1 Maximus
-
- Protocol Hydra
- Type Batch
- Type Bi
-
- LogFile Hydra%K.Log
- ControlFile Hydra%K.Ctl
- ; Put in NOS (nostamp) to not retain date/time on received files
- DownloadCmd HydraCom.Exe por %P spe %W lin %b dro nor nob res
- %x:Hydra%K.Log rec %v sen @%x:Hydra%K.Ctl
- UploadCmd HydraCom.Exe por %P spe %W lin %b dro nor nob res
- %x:Hydra%K.Log rec %v get
- DownloadString %s
- UploadString
- DownloadKeyword H
- UploadKeyword R
- FilenameWord 10
- DescriptWord 0
- End Protocol
-
- Note that the DownloadCmd and UploadCmd lines are both a bit long and
- therefore wrapped in this document.
-
- Maximus would also be capable of using the Opus mechanism instead of
- using DSZ-style, but Maximus 2.00 and 2.01wb have a bug in that code
- which causes it to pass invalid data in the controlfile.
-
-
- 4.3.2 Opus
-
- Opus expects you to specify the path and file name of HydraCom in your
- Opus control file. Usually, you would want the user to invoke Hydra
- with the H keystroke, so the name of the HydraCom executable should
- start with a H, like HydraCom.EXE. In this case, you should add an
- external file transfer protocol line to your Opus control file which
- (in case HydraCom.EXE resides in the c:\opus directory) reads:
-
- External_file_protocol C:\OPUS\HydraCom.EXE
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- HydraCom Page 27
-
-
-
- Page 28 HydraCom
-
- 4.3.3 QuickBBS and RemoteAccess (FileDoor)
-
- You can offer HydraCom from QuickBBS, RemoteAccess and similar
- packages with the FileDoor program. For that, you would have to add
- the specifications for HydraCom to your filedoor configuration file:
-
- Protocol 96 T U 20 0 Hydra
- Usage 0 0 N Y 38400
- BiDSZ HYDRACOM.EXE por $1 spe 38400 lin $2 nob rec $8 sen $3 $M
-
- Protocol 96 T D 20 0 Hydra
- Usage 0 0 N Y 38400
- BiDSZ HYDRACOM.EXE por $1 spe 38400 lin $2 nob rec $8 sen $3 $M
-
- These settings only apply if you use a modem locked at 38400.
- For information about which settings to change for your modem, please
- refer to the FileDoor documentation and config comments.
-
-
- 4.3.4 RBBS-PC
-
- RBBS-PC uses a file called PROTO.DEF to define the external protocols.
- Here is a sample PROTO.DEF. Please refer to the RBBS-PC documentation
- for information concerning the syntax.
-
- "H)ydra
- ",0,S,8,,B,1024,,0.96,,1=E,"D:HydraCom.EXE port [PORT#] speed [BAUD]
- dropdtr result D:XFER-[NODE].DEF send [FILE]","D:HydraCom.EXE port
- [PORT#] speed [BAUD] dropdtr result D:XFER-[NODE].DEF get [FILE]"
-
- It is one physical line which should not have any CR/LF in the middle.
-
-
- 4.3.5 Wildcat!
-
- Wildcat! is a commercial Bulletin Board package, this paragraph will
- cover the implementation of HydraCom within the Testdrive version. You
- should create a path to your external protocols, like C:\WILDCAT\EP,
- where you should store all files related to external file transfers.
- Wildcat! will also temporarily store the sent and received files
- there. You should also specify this path in the Wildcat! set-up
- program, (MakeWild) and don't forget to add to the number of external
- transfer protocols, also in the set-up program. After that, you should
- define HydraCom within the external protocol definition part of the
- set-up. LTR defines the key which a user should press in order to
- invoke the transfer batch file. At the Up.BAT position, you should
- define the HydraCom upload batch file and at the Dn.BAT you should
- define the HydraCom download batch file. Setting the Batch field to
- Y(es) will allow a batch (multiple files) of files for up- or
- downloading, this is recommended, though the test-drive version does
- not support batch uploads. Please note that users cannot invoke
- external protocols during the period between an event and two hours
- before the start of that event.
-
-
-
- Page 28 HydraCom
-
-
-
- HydraCom Page 29
-
- Wildcat! spawns to dos upon exit to HydraCom and will assign the baud
- rate to DOS variable %1, the communications port is assigned to
- variable %2 and the file name(s) (without path) are assigned from
- variable %3 to variable %9. The batch files must be located in the
- external protocol directory. Your download batch file would be:
-
- CD \WILDCAT\EP
- HydraCom.EXE port %2 speed %1 sz %3 %4 %5 %6 %7 %8 %9
- CD \WILDCAT
-
- and your upload batch file could, for example, become:
-
- CD \WILDCAT\EP
- HydraCom.EXE port %2 speed %1 rz [%3]
- COPY %3 [%5]%4
- DEL %3
-
- where the %3 variable denominates the file which is to be received,
- but this does not need to be specified to make HydraCom receive a
- file. Variable %4 contains the path to an upload directory which has
- been specified by the user and variable %5 contains the full drive,
- path and file name. The latter two variables can be useful in the
- batch file which calls HydraCom, for example to move files directly to
- an upload area. These batch files should be named according to the
- batch file names which you filled in under Up.BAT and Dn.bat in the
- MakeWild set-up program. To allow as many (seven, %3 to %9) files to
- be downloaded in one batch as possible, Wildcat! does not use a path,
- but only uses the external protocol directory. Wildcat! will copy
- files which are to be sent to this directory (and delete them after
- the transfer) and will receive files into this directory, a DOS
- command line is limited to 128 characters, so this saves a path
- denomination before each file.
-
- You can edit PROTOCOL.HLP and add information about HydraCom to it for
- your users.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- HydraCom Page 29
-
-
-
- Page 30 HydraCom
-
- 4.3.6 XBBS
-
- The internal XBBS version 1.06 method:
- XBBS needs a PROTOCOL.TXT, which is made into PROTOCOL.CTL by
- XPROTO.COM. You could add the next lines to PROTOCOL.TXT in order to
- install HydraCom in your XBBS.
-
- ;sample PROTOCOL.TXT for HydraCom
- Hydra ;Protocol label
- H ;Key to select protocol
- 96 ;Protocol efficiency
- C:\XBBS\HydraCom.EXE PORT *p SPEED *B send *F;Download string
- C:\XBBS\HydraCom.EXE PORT *p SPEED *B get ;Upload string
- type a dozen CTRL-X's ;Abort string
- Y ;Wildcards?
- Y ;Multiple file names?
- Y ;Simultaneous U/D?
- Y ;use @listfile?
- Y ;remote filename?
- Y ;Use DSZlog?
- N ;not yet used
- N ;not yet used
-
- Please refer to the XBBS documentations for the exact meaning of the
- PROTOCOL.TXT statements.
- Then run XPROTO PROTOCOL.TXT in the XBBS home directory and you got
- yourself a PROTOCOL.CTL with HydraCom.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Page 30 HydraCom
-