home *** CD-ROM | disk | FTP | other *** search
- Yamaha TG100
- Serial Device Driver
- Version 1.0
-
- Overview:
- ---------
- The Yamaha Serial Device Driver allows Windows 3.1 users to attach the
- Yamaha TG100 to their computer's serial port. Follow the direction in the
- manual concerning cabling and the appropriate switch setting on the rear panel.
-
- Note:
- -----
- This device driver is only compatible with Windows 3.1.
-
- Hardware Installation:
- ---------------------
- Connect the TG100 to the computer using the cable recommended in the
- Reference Manual and set the switch on the back of the TG100 as described
- in the Reference Manual.
-
- Note that the driver will not load if the TG100 is not connected to the
- specified COM port and/or is not powered on when Windows loads. The driver
- verifies the existence of the TG100 before fully initializing.
-
- Standard mode users should also be aware that due to the way the Windows
- COM drivers are written, it is impossible to place the TG100 on a shared
- interrupt port. In ISA bus machines, if there are more than two COM ports,
- ports 1 and 3 share interrupt 4 and ports 2 and 4 share interrupt 3. On MCA
- machines, port 1 uses interrupt 4 and all other ports share interrupt 3.
- On EISA machines either sharing scheme is possible depending on the type
- of COM boards used.
-
- Therefore, standard mode users should set the TG100 on COM port 1 to assure
- compatibility and, on ISA or some EISA machines (depending on the type of
- COM board) disable COM port 3.
-
- Software Installation:
- ---------------------
- To install the device driver, simply bring up the Windows Control Panel
- application (typically found in Main group) and select the Drivers icon.
- Press the Add button and select the Unlisted or Updated Driver entry from
- the list box and press OK. Respond to Windows prompt concerning the location
- of the driver and press OK. The driver will then display a list of COM ports
- available for the TG100. Select the appropriate COM port and press OK.
- Windows will then ask if you wish to restart Windows. You must restart
- Windows for the installation to be completed.
-
- If you install the driver while running in Standard mode on a 386 and later
- want to run in Enhanced mode, it will be necessary to re-install the driver
- to cause Windows to load the 386 driver files. If you install the driver in
- Enhanced mode first and later want to run in Standard mode no actions are
- necessary: Windows will have already loaded all of the necessary files.
-
- Enhanced versus Standard Mode:
- ------------------------------
- This driver is capable of support Windows running in both Enhanced mode and
- Standard mode. The Standard mode capability is primarily provided for users
- of 80286 based systems and/or users that have applications that only run in
- Standard mode.
-
- This driver has been tested in Standard mode on 80286 machines with clock
- speeds starting at 12MHz and in Enhanced Mode on 80386SX machines with
- clock speeds starting at 16 MHz.
-
- SYSTEM.INI Settings:
- --------------------
- The following values can be defined under the [TG100.DRV] section of your
- SYSTEM.INI file:
-
- [SysExWait=nn]
- Because of the interrupt latency in Windows, it is impossible for slow
- machines to keep up with a SysEx dump a byte at a time. For this reason,
- when the device driver recognizes that the TG100 is sending a SysEx dump, it
- will hold on to the COM port until the completion of all pieces of a SysEx
- dump. Upon recognizing the completion of the SysEx dump the driver will pass
- the SysEx data to the MIDI application. Note that the entire SysEx dump must
- first be received by the driver before data is passed to the MIDI
- application.
-
- By default the device driver will wait 40 milliseconds to determine that a
- SysEx dump is complete. If no more data is received in this time interval
- the data received will then be forwarded to the MIDI application.
-
- You can change this interval by setting the SysExWait setting in the
- TG100.DRV section of the SYSTEM.INI file. The value given is in
- milliseconds: i.e. SysExWait=100 would cause the driver to wait 100
- milliseconds instead of the default 40 milliseconds.
-
- Users should consider adjusting this value if they are having problems
- getting complete SysEx dumps.
-
- [COMPort=n]
- This specifies which COM port the TG100 is attached to and must appear
- in the TG100.DRV section of the SYSTEM.INI file.
-
- [BufferSize=nnnn]
- This specifies the number of bytes that should be made available to handling
- SysEx dumps. This can be any value from 1 to 65535: the default value is
- 10240.
-
- Users should consider adjusting this value if they plan on receiving large
- SysEx dumps from MIDI devices attached to the TG100.
-
- [MIDIINPersistence=nn]
- This specifies the number of bytes the driver will read from the TG100 before
- returning control to Windows (except in the case of SysEx dumps with are read
- until the dump time interval specified by the SysExWait expires). The default
- value is 50 which should be adequate for most installations.
-