home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1993 #3 / NN_1993_3.iso / spool / comp / sys / amiga / hardware / 23712 < prev    next >
Encoding:
Text File  |  1993-01-26  |  1.9 KB  |  44 lines

  1. Newsgroups: comp.sys.amiga.hardware
  2. Path: sparky!uunet!nwnexus!curtjb
  3. From: curtjb@halcyon.com (Curt Brown)
  4. Subject: Re: SCSI spin-up time and boot sequence
  5. Message-ID: <1993Jan26.081325.26427@nwnexus.WA.COM>
  6. Sender: sso@nwnexus.WA.COM (System Security Officer)
  7. Organization: The 23:00 News and Mail Service
  8. Distribution: na
  9. Date: Tue, 26 Jan 1993 08:13:25 GMT
  10. Lines: 32
  11.  
  12. >lewis@ratty.mits.com.au wrote:
  13. >: In article <>, Tomm@nameless.cpr.sub.org (Karsten_Storck) writes:
  14. >: > Randy Byers (rmbyers@bfield.uucp) wrote:
  15. >: This isn't true, since my GVP drive boots from a Quantum with ID 0,
  16. >: and yet still scans and finds the slow, old Miniscribe at ID 1 which
  17. >: has a lower boot priority.  But I also have the problem that I have
  18. >: to turn on the Miniscribe 20secs or more before the computer, so
  19. >: that the drive is recognised on startup.  At least it's an external
  20. >: drive.
  21. >
  22. >But the hostadapter waits to short, after finding one drive, with my
  23. >solution, it waits longer and I boot from an slower drive and have the
  24. >faster one immediatly:-)
  25.  
  26. Set the SCSI ID of the slow-to-spin-up drives _lower_ than the
  27. fast-to-spin-up drives, and you might be OK.  I have two ancient Priam
  28. ID-130 drives and a (relatively) fast Quantum 52LPS connected to my
  29. A3000.  The Quantum spins up very fast, and is set to SCSI ID 6.  The
  30. Priams spin up very slowly (30-40 S.) and are set to SCSI ID 0 (they
  31. are connected via an Adaptec converter).
  32.  
  33. Even thought the Quantum (my boot drive) spins up in a few seconds, the
  34. A3000 waits until the device on SCSI ID 0 is ready before booting from
  35. the Quantum. I power up the A3000 and the external Priams at the same
  36. time.  I prefer this method, because I'm not forced to boot from the
  37. slower drive and I can leave the Priams home if I take my A3000 to a
  38. friend's house.
  39.  
  40. Hopefully your GVP host adapter will work the same way.  If not, I'm
  41. glad that the folks that designed the A3000 SCSI put in this extra
  42. little touch.
  43.  
  44.