- Newsgroups: comp.os.os2.misc
- Path: sparky!uunet!n3dmc!johnl
- From: johnl@n3dmc.svr.md.us (John Limpert)
- Subject: Re: HELP! Floppy trouble
- Organization: N3DMC, Silver Spring, Maryland
- Date: Sun, 24 Jan 1993 16:32:42 GMT
- Message-ID: <C1D9yL.3HL@n3dmc.svr.md.us>
- X-Newsreader: Tin 1.1 PL5
- References: <1993Jan24.021551.16595@news.acns.nwu.edu>
- Lines: 13
-
- Sounds like a problem with the disk change line. There may be a jumper
- on the floppy disk drive that is set incorrectly. Look for a jumper
- labelled AT/XT or DSK CHG. It can also be a drive or controller problem.
- On one system that had this problem we had to replace the disk drive
- (Mitsumi) and the floppy controller because neither one was designed
- to support the disk change line.
-
-
- --
- John A. Limpert
- johnl@n3dmc.svr.md.us