  1. Xref: sparky bit.listserv.ibm-main:3073 bit.listserv.ibm-nets:278
  2. Path: sparky!uunet!zaphod.mps.ohio-state.edu!uwm.edu!psuvax1!psuvm!pmw1
  3. Organization: Penn State University
  4. Date: Thu, 21 Jan 1993 08:51:37 EST
  5. From: Peter M. Weiss <PMW1@psuvm.psu.edu>
  6. Message-ID: <93021.085137PMW1@psuvm.psu.edu>
  7. Newsgroups: bit.listserv.ibm-main,bit.listserv.ibm-nets
  8. Subject: Re: 3274 A ports display as B?
  9. References: <93020.150303SHILL@HARPERVM.BITNET>
  10. Lines: 21
  11.  
  12. In article <93020.150303SHILL@HARPERVM.BITNET>, Steve W Hill
  13. <SHILL@HARPERVM.BITNET> says:
  14.  
  15. >Are there any normal instances where a terminal attached to an A port
  16. >on a 3274 (41A) will display a "B" in the status line instead of an "A"?
  17.  
  18. >If not, does something need to be reconfigured via software, or is a
  19. >hardware change required?
  20.  
  21. It is my understanding that the display of "A" or "B" in in Operator
  22. Information Area (OIA), second column, does _not_ related to the
  23. adapter port, but does indicate whether the device (control unit) is
  24. operating in non-SNA ("A") or SNA ("B") mode.  On a DFT device, the OIA
  25. may not be exactly the same as on a dumb (oops, non-programmable
  26. workstation) terminal.
  27.  
  28. /Pete (pmw1@psuvm.psu.edu)
  29. --
  30. Peter M. Weiss                     | not affiliated with psuvm.psu.edu|psuvm
  31. 31 Shields Bldg -- Penn State Univ.| "Connectivity is more than a Connection"
  32. University Park, PA USA 16802-1202 | E. Michael Staman, _The Circuit_, Apr 92