home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1993 #3 / NN_1993_3.iso / spool / bit / listserv / ibm7171 / 148 < prev    next >
Encoding:
Text File  |  1993-01-28  |  2.3 KB  |  50 lines

  1. Comments: Gated by NETNEWS@AUVM.AMERICAN.EDU
  2. Path: sparky!uunet!munnari.oz.au!spool.mu.edu!howland.reston.ans.net!paladin.american.edu!auvm!UKANVM.BITNET!NORDLUND
  3. Message-ID: <IBM7171%93012708530916@VM.TCS.TULANE.EDU>
  4. Newsgroups: bit.listserv.ibm7171
  5. Date:         Wed, 27 Jan 1993 08:52:16 CST
  6. Sender:       Protocol Converter list <IBM7171@TCSVM.BITNET>
  7. From:         Dave Nordlund <NORDLUND@UKANVM.BITNET>
  8. Subject:      Re: Dialup Problems
  9. In-Reply-To:  Message of Tue,
  10.               26 Jan 1993 08:51:48 EDT from <BHART@KENTVM.KENT.EDU>
  11. Lines: 37
  12.  
  13. On Tue, 26 Jan 1993 08:51:48 EDT Bob Hart said:
  14. >I'm  experiencing dialup (switched) connection problems on our 7171.
  15. >
  16. >7171 ports set to 1A00 - 7,E,1 autoconfigure, autobaud
  17. >Modem's buffer and MNP off. Will accept 300 to 9600 baud.
  18. >
  19. >User's using higher than 2400 baud are reporting that after the
  20. >'connect' msg is received, the "TERMINAL TYPE:" prompt fails to appear
  21. >60-80% of the time after hitting <CR>. This also happens to a
  22. >lesser degree at 2400 sometimes.
  23. >
  24.  
  25. Why don't you use a fixed baud rate at the modem serial port (maybe 9.6)
  26. and on the 7171 port.  Configure the modem to do buffering but not compression.
  27. Then you don't need the autobaud on the 7171.  Oh- it helps to change the
  28. speed at which the 7171 does ifficient screen management.  It comes default
  29. at 7200.  That means that even 300 bps connections would not get the effecient
  30. screen updates.
  31. We have our 7171s connected to a campus wide X.25 network and all ports are
  32. fixed at 9,600.  Almost no problems even for people dialing in at 300.
  33.  
  34. >Without getting into too many details at this point, has anyone else
  35. >experienced a similar problem and maybe know why this is happening?
  36. >I do have a datascope and test modems/ports setup, as I have been
  37. >looking into this now for many weeks. I'm beginning to suspect that
  38. >the 7171 ports are just too darn sensitive, and lock up on me.
  39. >
  40. >-----------------------------------------------------------------
  41. >Bob Hart               BITNET: BHART@KENTVM
  42. >Technical Support    INTERNET: bhart@kentvm.kent.edu
  43. >Computer Services              (216) 672-7971
  44. >Kent State University          Kent, Ohio
  45.  
  46.          Dave Nordlund                 Associate Director
  47.          Computing Services            University of Kansas
  48.          NORDLUND@UKANVM.BITNET        nordlund@ukanvm.cc.ukans.edu
  49.          913/864-0450
  50.