home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1992 #31 / NN_1992_31.iso / spool / comp / sys / dec / 6647 < prev    next >
Encoding:
Text File  |  1992-12-30  |  2.0 KB  |  58 lines

  1. Newsgroups: comp.sys.dec
  2. Path: sparky!uunet!math.fu-berlin.de!news.th-darmstadt.de!cygnus.frm.maschinenbau.th-darmstadt.de!SYSGAERTNER
  3. From: sysgaertner@cygnus.frm.maschinenbau.th-darmstadt.de (M. Gaertner, FRM, TH Darmstadt, Germany)
  4. Subject: What about this config ?
  5. Sender: news@news.th-darmstadt.de (The News System)
  6. Message-ID: <1992Dec30.134706.23172@news.th-darmstadt.de>
  7. Date: Wed, 30 Dec 1992 13:47:06 GMT
  8. Reply-To: sysgaertner@cygnus.frm.maschinenbau.th-darmstadt.de
  9. Nntp-Posting-Host: cygnus.frm.maschinenbau.th-darmstadt.de
  10. Organization: Fachbereichsrechner Maschinenbau, TH Darmstadt, Germany
  11. Lines: 45
  12.  
  13. Hi there,
  14. I'm just trying to configure my little uVAX II with a new disk-controller.
  15. I looked up all the bus-loads and power lines, added them and I know
  16. want to know your opinion to that:
  17. Guess the following:
  18. 1 * BA23-Box
  19. 1 * KA630
  20. 1 * MA630-B* (4MB)
  21. 1 * MA630-C* (8MB)
  22. 1 * DELQA
  23. 1 * DZQ11
  24. 1 * KDA50 (Yes, I know not supported in BA23, but does it work ?!)
  25. 1 * TKQ50
  26. 1 * TK50
  27. -----------
  28. So far, power on 5V = 32.5 A, max. is 36A
  29.         power on 12V = 1.03 A, max is 7A
  30. I did not find any max. bus-loads, but sum so far is:
  31. AC : 12.4   DC: 3.5
  32.  
  33. This should be fine so far (except the unsupported KDA50)
  34. I now want to add:
  35. 1 * RQDX3
  36. 1 * RQDXE
  37. ---------------
  38. power 5V = 35.48 A
  39. power 12V = 1.1 A
  40. AC: 14.3    DC: 5
  41.  
  42. Well, power at 5V is pretty close to the limit. Will this work stable ??
  43. What about the bus-loads ?
  44. Btw. currently the system is running with 
  45. RQDX3, RQDXE, KA630, MA630-B*, MA630-C*, 2*DZQ11, DELQA, TKQ50, TK50
  46.  
  47. So, I want to expand my disk-space with some RA-disks, thus adding the KDA50.
  48. Ok, any thoughts ? May I add the RQDX or may I better leave it ? Oh, I have a 
  49. spare PC-powersupply (200W), I could add this one to my box...
  50.  
  51. -----------------------------------------------------------------------------
  52.  
  53.                       M. Gaertner
  54.                 TH Darmstadt, W. Germany
  55.          Rechnergruppe FB 16-Maschinenbau
  56.       SYSGAERTNER@CYGNUS.FRM.MASCHINENBAU.TH-DARMSTADT.DE
  57.       Phone: Germany, (0)6151/16 5145
  58.