home *** CD-ROM | disk | FTP | other *** search
/ NetNews Usenet Archive 1992 #31 / NN_1992_31.iso / spool / comp / misc / 4694 < prev    next >
Encoding:
Internet Message Format  |  1992-12-23  |  1.6 KB

  1. Path: sparky!uunet!consult!bob
  2. From: bob@consult.UUCP (Bob Willey CDP)
  3. Newsgroups: comp.misc
  4. Subject: Re: Help: 256-Gray Scanner
  5. Message-ID: <1269@consult.UUCP>
  6. Date: 23 Dec 92 22:57:00 GMT
  7. References: <92357.63484.J024330@LMSC5.IS.LMSC.LOCKHEED.COM>
  8. Reply-To: bob@consult.UUCP (Bob Willey CDP )
  9. Organization: CCS Enterprises, Inc. - Easton, MD
  10. Lines: 24
  11.  
  12. In article <92357.63484.J024330@LMSC5.IS.LMSC.LOCKHEED.COM> J024330@LMSC5.IS.LMSC.LOCKHEED.COM writes:
  13. >I am trying to install a Mouse Systems 256/Gray Scale Hand Scanner into
  14. >a clone.  There is a proaudio spectrum 16 set to 220H DMA3 and IRQ7.
  15. >I've set the scanner to 270h, 2E0h, 370h, and 3E0h and to DMA and/or IRQ
  16. >that will not interfere with the sound board.  It won't work properly.
  17. >It writes temporary files (albiet very small) but won't put the image on
  18. >the screen.  Any suggestions?
  19.  
  20. Not sure if it is the same problem, but we recently had similar problems
  21. with a Logitech 256 ScanMan.
  22.  
  23. What it turned out to be was the bus speed on the 486Sx25 was set too
  24. fast.  In the AMI/BIOS we had to set the Bus Select to 2/4 and everything
  25. went fine.  In other words it is a timing problem with some of the older
  26. designed cards that were never designed to handle the newer higher performance
  27. PC's that are available now.
  28.  
  29. Hope this helps.
  30.  
  31. -- 
  32. >.. Bob Willey, CDP          ..  |  ..  uunet!consult!bob  bob@ccs.com   ..<
  33. >.. CCS Enterprises, Inc.    ..  |  ..   Office: (410) 820-4670          ..<
  34. >.. P.O. Drawer 1690         ..  |  ..      FAX: (410) 476-5261          ..<
  35. >.. Easton, Maryland 21601 ......|......... BBS: (410) 476-5098 ...........<
  36.