  13. In article <BxsM1p.Cw1.1@cs.cmu.edu>, roberts@cmr.ncsl.nist.gov (John Roberts) 
  14. writes:
  15. > Anything on what degrees of motion can be adjusted? (i.e. swing angle,
  16. > arm length, tilt, spacing.)
  17.  
  18. Basically, each optical channel of COSTAR is adjustable for focus, x-tilt, 
  19. and y-tilt via stepper motors.  After deployment, each mechanism will be 
  20. scanned back and forth through a successively finer range, and images will 
  21. be taken to find the best settings.  
  22.  
  23. The WFPC-2 should be installed at the same time as COSTAR and has stepper 
  24. motors to adjust the pick-off mirror in x or y.  Also the tip and tilt of
  25. fold mirrors inside three of the four cameras will be adjusted via electro-
  26. strictive devices - a bit of exotic technology, since there isn't room
  27. for stepper motors there.