- In article <1992Nov15.121008.12717@pt.com> jjg@pt.com (John Grana) writes:
- >In article <MRD.92Nov13160506@morsel.stdavids.picker.com> mrd@morsel.stdavids.picker.com (Michael DeCorte) writes:
- >>
- >>As long as you are terminating everything correctly and your external
- >>cables are shielded and you don't have very long cables then active
- >>termination will solve your problems.
- >>
- >I agree with Michael!
- >
- [lots of stuff deleted]
-
- I have been having a problem with 2 external 1.2G disks on a sparc 2
- which also has an internal 424M and 2 external tape drives (QIC and 8mm).
- Thus a total of 5 scsi devices.
- The external disks are both SEAGATE Wren VIII ST41650N
-
-
- Every week or so we would get an error message like the following.
- It always occurs when accessing sd2 under heavy io.
- Although it may be that it happens when both drives are active.
- It only happens when both drives are on the bus.
- In this case, I was doing a restore onto sd2..
-
- vmunix: esp0: Current command timeout for Target 2 Lun 0
- vmunix: esp0: State=SELECT (0x20), Last State=FREE (0x0)
- vmunix: esp0: Cmd dump for Target 2 Lun 0:
- vmunix: esp0: cdb=[ 0xa 0xc 0x41 0xb0 0x10 0x0 0x0 0x0 0x0 0x0 ]
- vmunix: sd2: SCSI transport failed: reason 'reset': retrying command
- vmunix: esp0: Target 3 now Synchronous at 4.0 mb/s max transmit rate
- vmunix: esp0: Target 3 now Synchronous at 4.0 mb/s max transmit rate
- vmunix: esp0: Target 1 now Synchronous at 4.0 mb/s max transmit rate
- vmunix: esp0: Target 1 now Synchronous at 4.0 mb/s max transmit rate
-
- With all the talk of active termination, I was wondering if
- this would help my problem. Also, I'm curiuos as to the
- practical limits of how many disks can be added.
-
- ------
- Michael Moscovitch
- michaelm@pike.ee.mcgill.ca
- --
- <Mike>
- michaelm@pike.ee.mcgill.ca
-