home *** CD-ROM | disk | FTP | other *** search
- Path: sparky!uunet!zaphod.mps.ohio-state.edu!uwm.edu!linac!att!ucbvax!TREMOR.MIT.EDU!krowitz
- From: krowitz@TREMOR.MIT.EDU (David Krowitz)
- Newsgroups: comp.sys.apollo
- Subject: Re: 3COM EtherLink Card
- Message-ID: <9211231542.AA29689@srvr1.engin.umich.edu>
- Date: 23 Nov 92 15:42:55 GMT
- Sender: daemon@ucbvax.BERKELEY.EDU
- Distribution: world
- Organization: The Internet
- Lines: 9
-
- The "Domain Series 3000 Configuration Worksheet" says that the Ethernet
- controller card (1st card of a possible 2) should have the interrupt
- request (IRQ) set to 10, the DMA request (DRQ) set to 6 in the I/O
- address range set to 300-307 (hex). The second card can be set to
- IRQ 9, DRQ 3, and I/O addr 310-317. Note that IRQ 10 is also used
- by the Ikon 10092 parallel printer interface card and/or the serial
- controller-AT card.
-
- == Dave Krowitz
-