home *** CD-ROM | disk | FTP | other *** search
- //
- // Values are 32 bit values layed out as follows:
- //
- // 3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
- // 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
- // +---+-+-+-----------------------+-------------------------------+
- // |Sev|C|R| Facility | Code |
- // +---+-+-+-----------------------+-------------------------------+
- //
- // where
- //
- // Sev - is the severity code
- //
- // 00 - Success
- // 01 - Informational
- // 10 - Warning
- // 11 - Error
- //
- // C - is the Customer code flag
- //
- // R - is a reserved bit
- //
- // Facility - is the facility code
- //
- // Code - is the facility's status code
- //
- //
- // Define the facility codes
- //
-
-
- //
- // Define the severity codes
- //
-
-
- //
- // MessageId: BRIDGE_E_INVALID_OUTPUT_ID
- //
- // MessageText:
- //
- // The output subsystem ID is invalid.
- //
- #define BRIDGE_E_INVALID_OUTPUT_ID ((HRESULT)0xC0040001L)
-
- //
- // MessageId: BRIDGE_E_INVALID_RESV_ID
- //
- // MessageText:
- //
- // The bandwidth reservation ID is invalid.
- //
- #define BRIDGE_E_INVALID_RESV_ID ((HRESULT)0xC0040002L)
-
- //
- // MessageId: BRIDGE_E_INVALID_ROUTE
- //
- // MessageText:
- //
- // The specified route does not match any entry in the filter table.
- //
- #define BRIDGE_E_INVALID_ROUTE ((HRESULT)0xC0040003L)
-
- //
- // MessageId: BRIDGE_E_INVALID_STATE
- //
- // MessageText:
- //
- // The specified output driver state code is not valid.
- //
- #define BRIDGE_E_INVALID_STATE ((HRESULT)0xC0040004L)
-
- //
- // MessageId: BRIDGE_E_ROUTE_EXISTS
- //
- // MessageText:
- //
- // The specified route already exists.
- //
- #define BRIDGE_E_ROUTE_EXISTS ((HRESULT)0xC0040005L)
-
- //
- // MessageId: BRIDGE_E_INSUFFICIENT_BANDWIDTH
- //
- // MessageText:
- //
- // The bandwidth reservation cannot be created or altered because
- // the maximum bandwidth of the target output subsystem would be exceeded.
- //
- #define BRIDGE_E_INSUFFICIENT_BANDWIDTH ((HRESULT)0xC0040006L)
-
- //
- // MessageId: BRIDGE_E_OUTPUT_MAX_REACHED
- //
- // MessageText:
- //
- // The bridge has reached its maximum number of output subsystems.
- // No more output subsystems can be installed.
- //
- #define BRIDGE_E_OUTPUT_MAX_REACHED ((HRESULT)0xC0040007L)
-
- //
- // MessageId: BRIDGE_E_INTERNAL_ERROR
- //
- // MessageText:
- //
- // The bridge encountered an internal error.
- // This error should not occur during normal usage.
- // Please check the event log on the server computer.
- //
- #define BRIDGE_E_INTERNAL_ERROR ((HRESULT)0xC0040008L)
-
- //
- // MessageId: BRIDGE_E_OUTPUT_VALUE_ERROR
- //
- // MessageText:
- //
- // The output driver returned invalid configuration data.
- // Make sure that the output subsystem driver DLL is compatable with
- // this version of the multicast router.
- //
- #define BRIDGE_E_OUTPUT_VALUE_ERROR ((HRESULT)0xC0040009L)
-
- //
- // MessageId: BRIDGE_E_INVALID_OUTPUT_VALUE
- //
- // MessageText:
- //
- // The value of the configuration is not a valid datatype.
- //
- #define BRIDGE_E_INVALID_OUTPUT_VALUE ((HRESULT)0xC004000AL)
-
- //
- // MessageId: BRIDGE_E_OUTPUT_VALUE_REJECTED
- //
- // MessageText:
- //
- // The output driver rejected the configuration data.
- // Make sure the index and data type of the configuration data is valid.
- // Please check the event log on the server computer.
- //
- #define BRIDGE_E_OUTPUT_VALUE_REJECTED ((HRESULT)0xC004000BL)
-
- //
- // MessageId: BRIDGE_E_OUTPUT_VALUE_NOT_SUPPORTED
- //
- // MessageText:
- //
- // The output driver does not support dynamic configuration.
- //
- #define BRIDGE_E_OUTPUT_VALUE_NOT_SUPPORTED ((HRESULT)0xC004000CL)
-
- //
- // MessageId: BRIDGE_E_OUTPUT_SET_STATE_ERROR
- //
- // MessageText:
- //
- // The output driver refused to change its state.
- // Please check the event log on the server computer.
- //
- #define BRIDGE_E_OUTPUT_SET_STATE_ERROR ((HRESULT)0xC004000DL)
-
- //
- // MessageId: BRIDGE_E_OUTPUT_DLL_LOAD_FAILED
- //
- // MessageText:
- //
- // The output driver DLL could not be loaded.
- // Please check to make sure that the driver DLL path is correct
- // and that the DLL is compatable with this version of the multicast router.
- // Please check the event log on the server computer.
- //
- #define BRIDGE_E_OUTPUT_DLL_LOAD_FAILED ((HRESULT)0xC004000EL)
-
- //
- // MessageId: BRIDGE_E_OUTPUT_DLL_INCOMPATABLE
- //
- // MessageText:
- //
- // The output driver DLL is not compatable with this version of the multicast router.
- //
- #define BRIDGE_E_OUTPUT_DLL_INCOMPATABLE ((HRESULT)0xC004000FL)
-
- //
- // MessageId: BRIDGE_E_REGISTRY_ERROR
- //
- // MessageText:
- //
- // A registry operation could not be completed.
- // Please check the event log on the server computer.
- //
- #define BRIDGE_E_REGISTRY_ERROR ((HRESULT)0xC0040010L)
-
- //
- // MessageId: BRIDGE_E_WINSOCK_ERROR
- //
- // MessageText:
- //
- // An error occurred in the WinSock subsystem.
- // Please check the event log on the server computer.
- //
- #define BRIDGE_E_WINSOCK_ERROR ((HRESULT)0xC0040011L)
-
- //
- // MessageId: BRIDGE_E_OUTPUT_NOT_LOADED
- //
- // MessageText:
- //
- // The operation could not be completed because the output driver is not loaded.
- // Please load the output driver first.
- //
- #define BRIDGE_E_OUTPUT_NOT_LOADED ((HRESULT)0xC0040012L)
-
- //
- // MessageId: BRIDGE_E_OUTPUT_STARTUP_FAILED
- //
- // MessageText:
- //
- // The output subsystem could not be started.
- // Please check the event log on the server computer.
- //
- #define BRIDGE_E_OUTPUT_STARTUP_FAILED ((HRESULT)0xC0040013L)
-
- //
- // MessageId: BRIDGE_E_OUTPUT_SHUTDOWN_PENDING
- //
- // MessageText:
- //
- // The operation could not be completed because the output subsystem is in the process of shutting down.
- //
- #define BRIDGE_E_OUTPUT_SHUTDOWN_PENDING ((HRESULT)0xC0040014L)
-
-