home *** CD-ROM | disk | FTP | other *** search
/ Revista CD Expert 42 / CDGAMER42.iso / INTERFACE / DICAS / ILDA32.DLL / string.txt next >
Text File  |  1997-11-08  |  8KB  |  192 lines

  1. 1    CREATIVE ERROR STRING TABLE
  2. 2          (c) Creative Developement LTD
  3. 3            11956 Riverside Dr. 206
  4. 4             N. Hollywood CA 91607
  5. 5     Phone: (818)766-3900  Fax: (818)766-9027
  6. 6     Tech Support:
  7. 7     Jan Dekkers, 72130.353@compuserve.com
  8. 65288    Unsupported JFIF revision number
  9. 65291    Application transferred too many scanlines
  10. 65292    Invalid SOS parameters for sequential JPEG
  11. 65293    Corrupt JPEG data: found a marker instead of a RST
  12. 65294    Premature end of JPEG file
  13. 65296    Corrupt JPEG data: bad Huffman code
  14. 65297    Corrupt JPEG data: premature end of data segment
  15. 65298    Corrupt JPEG data: extraneous bytes before marker
  16. 65300    Unknown Adobe color transform code
  17. 65340    No LZW Patent!  Read manual for Unisys Patent Information
  18. 65341    The Rotate Image 90 degrees (clockwise) operation failed
  19. 65342    The Rotate Image 180 degrees operation failed
  20. 65343    The Flip Image operation failed
  21. 65344    Invalid 24 bit PCX image
  22. 65345    Invalid 8 bit PCX image
  23. 65346    Invalid 4 bit PCX image
  24. 65347    Invalid DIB given for PCX write function
  25. 65348    Cannot use a RLE DIB for PCX write function
  26. 65349    The Palette is missing in PCX image
  27. 65350    This feature is not currently implemented
  28. 65351    DLL was not initialized correctly!!
  29. 65352    Error enabling Source
  30. 65353    Tranfer failed with pending tranfers
  31. 65354    Transfer failed
  32. 65355    Transfer cancelled with pending tranfers
  33. 65356    Tranfer cancelled by user or source
  34. 65357    Error at end of tranfer
  35. 65358    Not in state 5 for transfer
  36. 65359    Error setting tranfer mechanism
  37. 65360    Error selecting a Source
  38. 65361    A Source is already open, cannot select new one
  39. 65362    Cannot disable Source
  40. 65363    Cannot enable Source, Source already enabled
  41. 65364    Cannot enable Source, No Source open
  42. 65365    Error closing Source
  43. 65366    Cannot close Source, Source is currently enabled
  44. 65367    Error closing Source, Source not open
  45. 65368    Unknown Code returned from Source
  46. 65369    Cannot open Source/Source Manager not open
  47. 65370    Error closing Source Manager
  48. 65371    A Source is Currently Open, Cannot close Source Manager
  49. 65372    Error Closing Source Manager/Source Manager not Open
  50. 65373    Error Opening TWAIN.DLL
  51. 65374    Error Opening Source Manager
  52. 65375    Unknown compression format not supported
  53. 65376    CCITT compression is not yet supported
  54. 65377    Invalid LZW code found in image data
  55. 65378    Baseline TIFF does not support Tiled image data
  56. 65379    Baseline TIFF does not support the image's Predicator
  57. 65380    Baseline TIFF does not support Extra Sampling
  58. 65381    Baseline TIFF does not support the image's Planar Configuration
  59. 65382    Baseline TIFF does not support the image Fill Order
  60. 65383    Baseline TIFF does not support JPEG compression
  61. 65384    Baseline TIFF does not support Group 4 Fax compression
  62. 65385    Baseline TIFF does not support Group 3 Fax compression
  63. 65386    Baseline TIFF does not support image pixel size
  64. 65387    Baseline TIFF does not support CIE image data
  65. 65388    Baseline TIFF does not support YCbCr image data
  66. 65389    Baseline TIFF does not support CMYK image data
  67. 65390    Transparency Masks are not supported in TIFF image
  68. 65391    TIFF image is not a Baseline TIFF image
  69. 65392    Image File Directory of TIFF image not found
  70. 65393    Invalid TIFF image
  71. 65394    Invalid BYTE ordering of TIFF data, not Intel or Motorola
  72. 65395    Invalid Resolution for this image type
  73. 65396    Error writing to file or stream
  74. 65397    ZLIB error
  75. 65398    Invalid Palette information found
  76. 65399    Invalid Filter value found
  77. 65400    Invalid Compression value found
  78. 65401    Invalid Interlaced value found
  79. 65402    Invalid Color Type and Bit Depth combination
  80. 65403    Invalid Color Type found
  81. 65404    Invalid Bit Depth found
  82. 65405    Invalid width or height found
  83. 65406    Invalid IHDR information
  84. 65407    Too many IDAT areas found
  85. 65408    Invalid information after IDAT
  86. 65409    Compression error
  87. 65410    Extra compressed data present
  88. 65411    Not enough image data
  89. 65412    Invalid attempt to read row data
  90. 65413    Bad CRC value
  91. 65414    Unknown critical information
  92. 65415    Out of place Text information
  93. 65416    Out of place Time information
  94. 65417    Out of place Offset information
  95. 65418    Out of place PHYS information
  96. 65419    Out of place History information
  97. 65420    Out of place Background information
  98. 65421    Out of place or invalid Tranformation information
  99. 65422    Out of place cHRM information
  100. 65423    Out of place sBIT information
  101. 65424    Out of place or invalid color palette
  102. 65425    No PNG Image
  103. 65426    Missing the IHDR
  104. 65427    Out of place IHDR
  105. 65428    Not a PNG image
  106. 65429    Out of Memory
  107. 65430    Cannot allocate more that 64K
  108. 65431    Error reading PNG image
  109. 65432    Error writing PNG image
  110. 65433    Error Not a 24bit input Dib
  111. 65434    Error converting 24 bit image to indexed image
  112. 65435    Invalid PNG image
  113. 65436    Invalid DIB data
  114. 65437    Cannot access output buffer
  115. 65438    Cannot access input buffer
  116. 65439    No color map found
  117. 65440    Read Error
  118. 65441    Invalid GIF image
  119. 65442    No screen descriptor in GIF image
  120. 65443    Bad Code Size in image
  121. 65444    Not a valid graphic image
  122. 65445    Error allocating buffer
  123. 65446    Invalid BMP image
  124. 65447    Invalid PCX pixel size
  125. 65448    Invalid PCX Image
  126. 65449    Cannot create output file
  127. 65450    Error allocation memory for DIB
  128. 65451    Cannot open the input file
  129. 65460    Write to XMS failed
  130. 65461    Read from XMS failed
  131. 65462    Image too wide for this implementation
  132. 65463    Virtual array controller messed up
  133. 65464    Unsupported marker type
  134. 65465    Application transferred too few scanlines
  135. 65466    Write failed on temporary file --- out of disk space?
  136. 65467    Seek failed on temporary file
  137. 65468    Read failed on temporary file
  138. 65469    Failed to create temporary file
  139. 65470    Invalid JPEG file structure: SOS before SOF
  140. 65471    Invalid JPEG file structure: two SOI markers
  141. 65472    Unsupported JPEG process: A SOF type
  142. 65473    Invalid JPEG file structure: missing SOS marker
  143. 65474    Invalid JPEG file structure: two SOF markers
  144. 65475    Cannot quantize to more than 256 colors
  145. 65476    Cannot quantize to fewer than 8 colors
  146. 65477    Cannot quantize more than 3 color components
  147. 65478    Insufficient memory
  148. 65479    Invalid JPG image
  149. 65480    A Quantization table was not defined
  150. 65481    JPEG datastream contains no image
  151. 65482    A Huffman table was not defined
  152. 65483    Backing store not supported
  153. 65484    Requested feature was omitted at compile time
  154. 65485    Not implemented yet
  155. 65489    Premature end of input file
  156. 65490    Empty input file
  157. 65491    Maximum supported image dimension is 65500 pixels
  158. 65492    Missing Huffman code table entry
  159. 65493    Huffman code size table overflow
  160. 65494    Fractional sampling not implemented yet
  161. 65495    Output file write error --- out of disk space?
  162. 65496    Input file read error
  163. 65497    Didn't expect more than one scan
  164. 65498    Write to EMS failed
  165. 65499    Read from EMS failed
  166. 65500    Empty JPEG image (DNL not supported)
  167. 65501    Bogus DQT index value
  168. 65502    Bogus DHT index value
  169. 65503    Bogus DHT counts value
  170. 65504    Bogus DAC value
  171. 65505    Bogus DAC index value
  172. 65506    Unsupported color conversion request
  173. 65507    Too many color components
  174. 65508    CCIR601 sampling not implemented yet
  175. 65509    Suspension not allowed here
  176. 65510    Buffer passed to JPEG library is too small
  177. 65511    Bogus virtual array access
  178. 65513    Improper call to JPEG library in wrong state
  179. 65515    Bogus sampling factors
  180. 65519    Invalid memory pool code
  181. 65520    Sampling factors too large for interleaved scan
  182. 65522    Bogus marker length
  183. 65523    Bogus JPEG colorspace
  184. 65524    Bogus input colorspace
  185. 65525    IDCT output block size not supported
  186. 65526    Invalid component ID in SOS
  187. 65527    Bogus buffer control mode
  188. 65528    MAX_ALLOC_CHUNK is wrong, please fix
  189. 65529    ALIGN_TYPE is wrong, please fix
  190. 65530    Sorry, there are legal restrictions on arithmetic coding
  191. 65535    An error occured during an image operation
  192.