  1. 1    | LockCallBack initialization error, could not register implementation.
  2. 2    | LockCallBack initialization error, could not make object ready.
  3. 3    | LockCallBack initialization error, could not register object host.
  4. 4    | No LockCallBack defined for cache lock.
  5. 5    | Null LockCallBack activated.
  6. 6    | Cannot activate callback for nil object.
  7. 7    | Cannot create cache lock since client has not registered a callback.
  8. 8    | Unable to set a %1, since process %2 on host '%3' already holds a %4.
  9. 9    | Unable to set a %1, since user '%2' already placed a %3 for %4 at %5.
  10. 10    | Unable to create a cacheLock, since process %1 on host %2 holds a %3 on the object.
  11. 11    | Unable to update a cacheLock, since user '%1' already placed a %2 for %3 at %4.
  12. 12    | Lock request was issued, but the process that requested the lock is still holding an out-of-date cache lock.
  13. 13    | Unable to release lock, since the object is not locked by process %1 on %2.
  14. 14    | Unable to release lock; Either the object is not locked or lockid %1 is invalid.
  15. 15    | Unknown lock id %
  16. 16    | Lock with invalid type %1 passed to %2.
  17. 17    | Cannot activate lockserver: there is another server running.
  18. 18    | Cannot 'makeOperable', since lockserver is already operable.
  19. 19    | Cannot perform '%', since the lockserver is not operable.  Try to reactivate the lockserver using 'makeOperable'.
  20. 20    | An incomplete lock description was passed to 'setLock'; at least the object, lock type, user, host and pid must be specified.
  21. 21    | More than one lock type was set in the lock description passed to 'setLock'.
  22. 22    | A lock type other than 'Read' or 'Write' was set in the lock description passed to 'setLock'.
  23. 23    | Only the user for who the lock is to be set ('%1'), user '%2' or the owner of the lockserver '%3' has permission to set a %4-lock on %5.
  24. 24    | An incomplete lock description was passed to 'removeLocks'; at least the locked object must be specified.
  25. 25    | Due to errors, %1 of the %2 matching lock(s) were not unlocked by 'removeLocks'.
  26. 26    | Only owner '%1', user '%2', or the owner of the lockserver '%3' has permission to remove %4-lock %5 on %6.
  27. 27    | Shutdown of lockserver is delayed since there are still clients active (with a total of %1 locks).
  28. 28    | Shutdown will proceed after the last lock has been removed.
  29. 29    | Could not upgrade read lock with id %1 to write lock.
  30. 30    | The lock is blocked by %1 other lock(s) of other clients.
  31. 31    | The lock has %1 instances.
  32. 32    | User '%1' already placed a write lock with id %2 for %3.
  33. 33    | Trying to open not yet created lockfile.
  34. 34    | Error creating file '%' for lock storage.
  35. 35    | Error opening lock storage '%'.
  36. 36    | Error closing lock storage '%'.
  37. 37    | Could not write to lock storage '%'.
  38. 38    | Could not read from lock storage '%'.
  39. 39    | Cannot make changes to the lock storage because of a previous error.
  40. 40    | Unable to recover locks from old lock storage.
  41. 41    | Invalid ObjectId %
  42.