home *** CD-ROM | disk | FTP | other *** search
-
- ; In the modem list below, MNP5 should be read as a synonym for "Error
- ; Correction with compression", and MNP4 as a synonym for "Error correction
- ; with compression disabled", i.e. these names are used even if the modem
- ; really uses V42/V42bis. This shorthand is used because anything else turns
- ; out to be incredibly long winded.
-
- ; The modem list only gives strings where they differ from INSTALL defaults.
- ; The default modem is 2400, no error correction, no init required, generic
- ; Hayes compatible. MNP in software.
-
- ------------------------
- <Direct Connect / Null Modem>
- ------------------------
- Generic Slow Modem (2400 bps and below)
- Init = ATQ0V1E1X1S0=0|
- ------------------------
- Generic Fast Modem (9600 bps and above)
- Init = ATQ0V1E1X1S0=0&C1&D2|
- Speed = 38400
- Hardware MNP
- ------------------------
- Acex 2400 V22bis+MNP5
- Init = ATQ0V1E1X1S0=0&D2&C1\J0\Q3\V1|
- Speed = 4800
- Disable EC = AT\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C1\N3|
- Hardware MNP
- ------------------------
- Amber Logic Mistral FX24s
- Init = ATS7=55S0=0|
- Speed = 2400
- Disable EC = AT&E0|
- Set MNP4 = AT&E1%C0|
- Set MNP5 = AT&E5%C1|
- Hardware MNP
- ------------------------
- Amstrad SM4000/MC2400
- Init = ATQ0V1E1X2S0=0F0&D2&C1|
- ------------------------
- ATI Technologies, Inc. 2400etc
- Init = ATB1E1L1M1N1TQ0V1W1X6&Q5&B1&C1&D2&K3&O1|
- Speed = 9600
- Disable EC = AT&Q0W0&B0&K0&O0|
- Set MNP5 = AT&Q5W1&B1&K3&O1|
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER|VOICE
- Hardware MNP
- ------------------------
- Best Data 2400B/2400X
- Init = ATB1E1Q0V1X4&C1&D2|
- Speed = 2400
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Software MNP
- ------------------------
- Best Data 9624F/FX FAX Modem
- Init = ATB1E1Q0V1X4&C1&D2&M0|
- Speed = 2400
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Software MNP
- ------------------------
- Best Data Smart One 1442F/FX FAX Modem
- Init = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
- Speed = 38400
- Disable EC = AT&Q6W0&K0|
- Set MNP4 = AT&Q5S46=136\N3W1&K3|
- Set MNP5 = AT&Q5S46=138\N3W1&K3|
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Hardware MNP
- ------------------------
- Best Data Smart One 9624FQ FAX Modem
- Init = ATB1E1Q0V1X4&C1&D2|
- Speed = 2400
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Software MNP
- ------------------------
- Boca Research BOCAFAX
- Init = ATB1E1Q0V1X4&C1&D2|
- Speed = 2400
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Software MNP
- ------------------------
- Boca BOCAMODEM M1440EW/M1440IW
- Init = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
- Speed = 38400
- Disable EC = AT&Q6W0&K0|
- Set MNP4 = AT&Q5S46=136\N3W1&K3|
- Set MNP5 = AT&Q5S46=138\N3W1&K3|
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Hardware MNP
- ------------------------
- Boca BOCAMODEM M2400E/M2400I
- Init = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
- Speed = 9600
- Disable EC = AT&Q6W0&K0|
- Set MNP4 = AT&Q5S46=136W1&K3|
- Set MNP5 = AT&Q5S46=138W1&K3|
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Hardware MNP
- ------------------------
- Boca BOCAMODEM PM1440
- Init = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
- Speed = 38400
- Disable EC = AT&Q6W0&K0|
- Set MNP4 = AT&Q5S46=136\N3W1&K3|
- Set MNP5 = AT&Q5S46=138\N3W1&K3|
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Hardware MNP
- ------------------------
- Boca Pocket Modem 96/24
- Init = ATB1E1Q0V1X4&C1&D2&Q0|
- Speed = 2400
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Software MNP
- ------------------------
- British Telecom PC424X
- Init = AT&FS0=0&D3&W|
- Failure = NO CARRIER|BUSY|NO DIALTONE|NO ANSWER|BLACKLISTED|ERROR
- Hangup =
- Dial Delay = 2
- ------------------------
- Compucom Speedmodem (9600)
- Init = AT&FX4E1Q0V1&C1&D2S0=0|
- Speed = 19200
- Disable EC = AT\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C1\N3|
- Hardware MNP
- ------------------------
- Cray Quattro 144
- Init = ATE1F0M1Q0V1X4&C1&D2&E1&I1&K2&Q0&U2%C1/Q1/S1/U0"U0S0=0|
- Speed = 38400
- Disable EC = AT&E0|
- Set MNP4 = AT&E1%C0|
- Set MNP5 = AT&E1%C1|
- Hardware MNP
- ------------------------
- Dacom Datamate
- Init = ATQ0V1E1X4S0=0&D2&C1|
- Speed = 4800
- Disable EC = AT\N0|
- Set MNP4 = AT\N3%C0|
- Set MNP5 = AT\N3%C1|
- Hardware MNP
- ------------------------
- Dacom DSL2123 (DTI)
- Init = |NP|~RESET|
- Speed = 1200
- Tone Dial = V23T|~TON|
- Pulse Dial = V23T|~PLS|
- Dial Suffix = |
- Connect = &WAT
- AutoAnswerOn = |NP|~AA|
- AutoAnswerOff= |NP|~RESET|
- ------------------------
- Dacom Quadplus
- Init = ATQ0V1E1X4S0=0&D2&C1F1\J1&B0\Q2\T0B0\X2|
- Speed = 4800
- Disable EC = AT\N0|
- Set MNP4 = ATS34=4\N3|
- Set MNP5 = ATS34=5\N3|
- Hardware MNP
- ------------------------
- Dataflex Pocket Stradcom
- Init = ATQ0V1E1X1S0=0|
- ------------------------
- Dataflex Quadcom V22bis
- Init = ATQ0V1E1X4S0=0&D2&C1\J0\Q3\V0S7=55|
- Speed = 4800
- Disable EC = AT\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C1\N3|
- Hardware MNP
- ------------------------
- Dataflex Quadcom 2400 + FAX
- Init = ATQ0V1E1X4S0=0&D2&C1|
- Speed = 4800
- Disable EC = AT&Q0|
- Set MNP4 = AT%C0&Q3|
- Set MNP5 = AT%C1&Q3|
- Hardware MNP
- ------------------------
- Dataflex PC Rapier +
- Init = AT&FS7=180S0=0|
- Speed = 19200
- Disable EC = AT\N0%C0|
- Set MNP4 = AT\N3%C0|
- Set MNP5 = AT\N3%C3|
- Hardware MNP
- ------------------------
- Datatronics Discovery 2400c
- Init = ATX4E1Q0V1S0=0|
- Speed = 2400
- ------------------------
- Datatronics Discovery 2400 (MNP)
- Init = ATX4E1Q0V1&C1&D2S0=0B0\J0\G0\Q3\V1|
- Speed = 4800
- Disable EC = AT\N0|
- Set MNP4 = AT\N3%C0|
- Set MNP5 = AT\N3%C1|
- Hardware MNP
- ------------------------
- Datronics Discovery 9600
- Init = ATQ0E1V1X1S7=255|
- Speed = 19200
- Disable EC = AT\Z|
- Set MNP4 = AT%C0\Y|
- Set MNP5 = AT%C1\Y|
- Hardware MNP
- ------------------------
- Dowty Quattro
- Init = ATQ0V1E1X3S0=0F0&D2&C1&A0&I0|
- Disable EC = AT&E0|
- Failure = NO CARRIER|BUSY|NO DIALTONE|NO ANSWER|BLACKLISTED|ERROR
- Hangup =
- ------------------------
- Dowty/Telebit Trailblazer
- Init = ATQ0E1V1X3S7=60S110=1|
- Disable EC = ATS95=0|
- Set MNP4 = ATS95=2|
- Set MNP5 = ATS95=2|
- Hardware MNP
- ------------------------
- Dynalink FAX Modem 2400
- Init = ATQ0V1E1X4S0=0|
- ------------------------
- E-Tech BulletModem PC1414MX/DX
- Init = ATB1E1Q0V1X4&C1&D2&L0$E3$F4$C1$X2|
- Speed = 38400
- Disable EC = AT$E0$F5$X0|
- Set MNP4 = AT$E3$F4$C0$X2|
- Set MNP5 = AT$E3$F4$C1$X2|
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Hardware MNP
- ------------------------
- E-Tech UFOMATE P1414MX/DX
- Init = ATB1E1Q0V1X4&C1&D2&L0$E3$F4$C1$X2|
- Speed = 38400
- Disable EC = AT$E0$F5$X0|
- Set MNP4 = AT$E3$F4$C0$X2|
- Set MNP5 = AT$E3$F4$C1$X2|
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Hardware MNP
- ------------------------
- Gandalf ACCESS Series 3242
- Init = AT&FX4E1Q0V1&C1&D2\J0\Q3\V0S0=0|
- Speed = 19200
- Disable EC = AT\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C1\N3|
- Hardware MNP
- ------------------------
- GVC Technologies FAX Modem 9648
- Init = ATB1E1Q0V1X4&C1&D2|
- Speed = 2400
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Software MNP
- ------------------------
- GVC Technologies Super Modem 2400
- Init = ATB1E1Q0V1X4&C1&D2&M0|
- Speed = 2400
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Software MNP
- ------------------------
- Hayes Generic
- Init = ATQ0V1E1X1S0=0|
- ------------------------
- Hayes V-Series 2400 Quadplus
- Init = ATX4E1Q0V1&C1&D2S0=0&K1W2|
- Disable EC = AT&Q0|
- ------------------------
- Hayes V-Series ULTRA Smartmodem 9600
- Init = ATX4E1Q0V1&C1&D2S0=0&K3W2|
- Speed = 38400
- Disable EC = AT&Q0|
- Set MNP4 = ATS46=0&Q5|
- Set MNP5 = ATS46=2&Q5|
- Hardware MNP
- ------------------------
- Hitec EC2400
- Init = ATE1Q1V1S0=0X4F0&D2&C1&I1B0&S0\Q2|
- Speed = 4800
- Disable EC = AT\N1|
- Set MNP4 = AT%C0\N2|
- Set MNP5 = AT%C1\N2|
- Hardware MNP
- ------------------------
- Hyundai HMD-2404M
- Init = ATE1Q1V1S0=0X4\J0\Q3&D2&C1B0|
- Speed = 9600
- Disable EC = AT\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C1\N3|
- Hardware MNP
- ------------------------
- Intel 2400/2400e V.42bis Modem
- Init = ATB1E1Q0V1X4&C1&D2\N3\V2\Q3\J0\C1%C1"H3|
- Speed = 9600
- Disable EC = AT\N0\V1\Q0\C1|
- Set MNP4 = AT\N3\V2\Q3\J0\C1%C0"H0|
- Set MNP5 = AT\N3\V2\Q3\J0\C1%C1"H3|
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Hardware MNP
- ------------------------
- Intel SatisFAXtion Modem/100
- Init = ATB1E1Q0V1X4&C1&D2|
- Speed = 2400
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Software MNP
- ------------------------
- Intel SatisFAXtion Modem/200
- Init = ATB1E1Q0V1X4&C1&D2\N3\V2\Q3\J0\C1%C1"H3|
- Speed = 9600
- Disable EC = AT\N0\V1\Q0\C1|
- Set MNP4 = AT\N3\V2\Q3\J0\C1%C0"H0|
- Set MNP5 = AT\N3\V2\Q3\J0\C1%C1"H3|
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Hardware MNP
- ------------------------
- Intel SatisFAXtion Modem/300
- Init = ATB1E1Q0V1X4&C1&D2\N3\V2\Q3%C1"H3|
- Speed = 38400
- Disable EC = AT\N0\V1\Q0|
- Set MNP4 = AT\N3\V2\Q3%C0"H0|
- Set MNP5 = AT\N3\V2\Q3%C1"H3|
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Hardware MNP
- ------------------------
- Intel SatisFAXtion Modem/400 /400e
- Init = ATB1E1Q0V1X4&C1&D2\N3\V2\Q3\J0\C1%C1"H3|
- Speed = 38400
- Disable EC = AT\N0\V1\Q0\C1|
- Set MNP4 = AT\N3\V2\Q3\J0\C1%C0"H0|
- Set MNP5 = AT\N3\V2\Q3\J0\C1%C1"H3|
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Hardware MNP
- ------------------------
- Kerridge (KNS) Micro Quad
- Init = ATV1X4&C1&D2&K2&E4S0=0|
- Speed = 4800
- Disable EC = AT&E0|
- Set MNP4 = AT&E8|
- Set MNP5 = AT&E4|
- Failure = ERROR|BUSY|NO CARRIER|NO DIALTONE|LINK FAILURE|BLACKLISTED
- Hardware MNP
- ------------------------
- Kerridge (KNS) Micro Quin (V32)
- Init = ATV1X4&C1&D2&K2&E4S0=0|
- Speed = 19200
- Disable EC = AT&E0|
- Set MNP4 = AT&E8|
- Set MNP5 = AT&E4|
- Failure = ERROR|BUSY|NO CARRIER|NO DIALTONE|LINK FAILURE|BLACKLISTED
- Hardware MNP
- ------------------------
- Mayze 24
- Init = ATV1X6Q0&Q0&C1&D2"U13*M0F0&G2%K2%U2&I1|
- Speed = 9600
- Disable EC = AT-E0|
- Set MNP 4 = AT-E1%C0|
- Set MNP 5 = AT-E1%C1|
- Hardware MNP
- ------------------------
- Mayze 96
- Init = ATX4E1Q0V1&C1&D2S0=0&Q6%K2%U2"U20|
- Speed = 38400
- Disable EC = AT-E0|
- Set MNP4 = AT%C0-E1|
- Set MNP5 = AT%C1-E1|
- Hardware MNP
- ------------------------
- Microcom/Tricom AX2410c
- Init = ATE1Q0V1S0=0X3&D2&C1&S1\D3\Q3\R1M1\J0\X1\V1|
- Speed = 4800
- Disable EC = AT\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C1\N3|
- Hardware MNP
- ------------------------
- Microcom/Tricom Tornado 10/42
- Init = ATX4E1Q0V1&C1&D2S0=0|~~AT\X1%G1\J0-M1\V2\G0\Q3|
- Speed = 4800
- Disable EC = AT\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C3\N3|
- Hardware MNP
- ------------------------
- Microcom/Tricom Tornado Quin 42
- Init = ATX4E1Q0V1&C1&D2S0=0%E1%G0\J0%L1\Q3|
- Speed = 9600
- Disable EC = AT\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C1\N3|
- Hardware MNP
- ------------------------
- Microcom/Tricom PC Quad
- Init = ATQ0V1E1X1&C1&D2&G2S7=60|
- Speed = 38400
- Disable EC = AT\Z|
- Set MNP4 = AT%C0\Y|
- Set MNP5 = AT%C1\Y|
- Hardware MNP
- ------------------------
- Microlin FX 32 Plus
- Init = ATQ0V1E1X1&C1&D2S0=0|
- Speed = 38400
- Disable EC = AT\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C3\N3|
- Hardware MNP
- ------------------------
- Microlink modem
- Init = AT&FQ0V1E1X1S0=0S50=1S57=0|
- ------------------------
- Miracom WS3000/WS4000
- Init = |~~ATZ|~~~ATQ0V1E1X1S0=0S7=59S9=6S10=25S22=0S31=0|
- ------------------------
- Miracom WS3000 MK2 MNP5
- Init = |~~ATZ|~~~ATQ0V1E1X1S0=0S22=0&I2&C1&D2|
- Speed = 4800
- Disable EC = AT\N0|
- Set MNP4 = AT\N2%C0|
- Set MNP5 = AT\N2%C1|
- Hardware MNP
- ------------------------
- Multitech 224EH
- Init = ATQ0V1E1S0=0&E4|
- Speed = 4800
- Disable EC = AT&E0|
- Set MNP4 = AT&E14&E2|
- Set MNP5 = AT&E15&E2|
- Hardware MNP
- ------------------------
- Multitech Multimodem V32
- Init = ATQ0V1E1S0=0&E4|
- Speed = 19200
- Disable EC = AT&E0|
- Set MNP4 = AT&E14&E2|
- Set MNP5 = AT&E15&E2|
- Hardware MNP
- ------------------------
- Omnitel 2400S+
- Init = AT&FQ0V1E1X4S0=0S37=3&C1&D2\Q2\J0\V1|
- Speed = 4800
- Disable EC = AT\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C1\N3|
- Hardware MNP
- ------------------------
- Pace Linnet 2400
- Init = ATQ0V1E1X1S0=0S50=1S57=0|
- ------------------------
- Pace Linnet Quad
- Init = ATC0E1Q0V1X4F0&A0&I1&K1&D2&C1&S1\Q0\N0S0=0\D0|
- Speed = 4800
- Disable EC = AT\P0|
- Set MNP4 = AT\C4\P3|
- Set MNP5 = AT\C5\P3|
- Hardware MNP
- ------------------------
- Pace Linnet 32
- Init = ATC0E1Q0V1X4F0&A0&I1&K1&D2&C1&S1\Q0\N0S0=0\D0|
- Speed = 38400
- Disable EC = AT\P0|
- Set MNP4 = AT\C4\P1|
- Set MNP5 = AT\C5\P2|
- Hardware MNP
- ------------------------
- Pace Series 4 2400S
- Init = ATQ0V1E1S0=0|
- ------------------------
- Pace Ultralink V32
- Init = AT&C1&D2Q0V1E1X1S7=60S0=0|
- Speed = 19200
- Disable EC = AT\P0|
- Set MNP4 = AT\C4\P3|
- Set MNP5 = AT\C5\P3|
- Hardware MNP
- ------------------------
- Penril Datacomm DLX V32
- Init = ATX4E1Q0V1S0=0|
- Speed = 19200
- Disable EC = AT\N0|
- Set MNP4 = AT\C4\N3|
- Set MNP5 = AT\C5\N3|
- Hardware MNP
- ------------------------
- PerfectData EasyModem 144E/I
- Init = ATB1E1N2Q0V1X4&C1&D2\N3\V1\Q3%C1|
- Speed = 38400
- Disable EC = AT\N0\V0\Q0|
- Set MNP4 = AT\N3\V1\Q3%C0|
- Set MNP5 = AT\N3\V1\Q3%C1|
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Hardware MNP
- ------------------------
- Pract. Peripherals 14400 FXSA+FAX
- Init = ATX4E1Q0V1W2S0=0N1&C1&D2&K3&Q5S36=7S46=2S48=7|
- Speed = 38400
- Disable EC = ATS36=3S46=0&Q6|
- Set MNP4 = ATS36=7S46=0&Q5|
- Set MNP5 = ATS36=7S46=2&Q5|
- Failure = NO CARRIER|NO ANSWER|NO DIALTONE|BUSY|ERROR
- Hardware MNP
- ------------------------
- Pract. Peripherals PM 2400PPM Pocket Modem
- Init = ATB1E1M4TQ0V1X4&C1|
- Speed = 2400
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Software MNP
- ------------------------
- Psion Dacom Goldcard (PCMCIA)
- Init = ATB0F0E1V1X4&K3&C1&D2|
- Speed = 19200
- Disable EC = AT%C0\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C3\N3|
- Hardware MNP
- ------------------------
- Psion Dacom PDM 3/30
- Init = ATB0F0X3E1V1&C1&D2|
- Speed = 9600
- Disable EC = AT%C0\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT&C3\N3|
- Hardware MNP
- ------------------------
- Psion Dacom PDM 4/40
- Init = ATB0F0X4E1V1&C1&D2&K2&J2|
- Speed = 19200
- Disable EC = AT%C0\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT&C3\N3|
- Hardware MNP
- ------------------------
- Psion Dacom PDM 50/60
- Init = ATB0F0E1V1X4&K3&C1&D2|
- Speed = 57600
- Disable EC = AT%C0\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C3\N3|
- Hardware MNP
- ------------------------
- QuickComm Spirit II V32bis & FAX
- Init = AT&FE1Q0V1X4S0=0&D2&C1*F3|
- Speed = 57600
- Disable EC = AT*E0|
- Set MNP4 = AT*E3|
- Set MNP5 = AT*E9|
- Hardware MNP
- ------------------------
- Racal-Milgo Maxam IV
- Init = ATE1Q0V1X4F0N1S0=0&I9&K1&L0&M0&D2&P0&C1&S1\Q0|
- Speed = 4800
- Disable EC = AT&E0|
- Set MNP4 = AT\C4&E1|
- Set MNP5 = AT\C5&E1|
- Hardware MNP
- ------------------------
- Racal-Milgo VI2422PA
- Init = ATX9E1Q0V1&C1&D2S0=0*C1*F2*H0*K0*P1|
- Disable EC = AT*E0|
- ------------------------
- Sonix Volante V32.terbo
- Init = AT&F0|
- Speed = 115200
- Disable EC = AT\N0%C0"H0|
- Set MNP4 = AT\N3%C0"H0|
- Set MNP5 = AT\N5%C1"H3|
- Failure = ERROR|BUSY|NO CARRIER|NO DIALTONE|NO ANSWER
- Hardware MNP
- ------------------------
- SupraFAXModem v.32bis
- Init = AT&F2S7=100S0=0|
- Failure = NO CARRIER|BUSY|NO DIALTONE|NO ANSWER|ERROR
- Speed = 38400
- Disable EC = AT\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C1\N3|
- Hardware MNP
- ------------------------
- SVA/Universal FAXMODEM 9624P/H
- Init = AT&FB0X3S0=0&C1&D2|
- ------------------------
- Tandata TM512
- Init = ATQ0V1E1X1S0=0|
- ------------------------
- Tandata TM512 (DTI)
- Init = |NP|~RESET|
- Tone Dial = V23T|~
- Pulse Dial = V23T|~
- Dial Suffix = |
- Connect = &WAT
- AutoAnswerOn = |NP|~AA|
- AutoAnswerOff= |NP|~RESET|
- ------------------------
- Techpower TP96/24 Pocket FAX modem
- Init = AT&FB0S0=0&C1&D2\V1\Q2|
- Speed = 4800
- Disable EC = AT\N0|
- Set MNP4 = AT%C0\N5|
- Set MNP5 = AT%C1\N7|
- Hardware MNP
- ;NOTE: the B0 field shown in the above init string configures the modem
- ; for CCITT operation when running at 1200 bps. US users would likely
- ; need to change that to B1, for Bell 212A operation.
- ------------------------
- Toshiba PCMCIA modem
- Init = ATB0F0E1V1X4&K3&C1&D2|
- Speed = 19200
- Disable EC = AT%C0\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C3\N3|
- Hardware MNP
- ------------------------
- Toshiba TC2400 Internal
- Init = ATQ0V1E1X2S0=0|
- Speed = 4800
- Disable EC = AT&E0|
- Set MNP4 = AT&E1|
- Set MNP5 = AT&E2|
- Hardware MNP
- ------------------------
- Twincom 96/42i Internal
- Init = ATX4E1Q0V1&C1&D2&K3S0=0|
- Speed = 19200
- Disable EC = AT\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C1\N3|
- Hardware MNP
- ------------------------
- Twincom 14.4DF V32bis + FAX
- Init = ATX4E1Q0V1W2S0=0N1&C1&D2&K3&Q5S48=7S36=4|
- Speed = 38400
- Disable EC = ATS36=1S46=136&Q6|
- Set MNP4 = ATS46=136&Q5|
- Set MNP5 = ATS46=138&Q5|
- Hardware MNP
- ------------------------
- USR Courier 2400e
- Init = ATQ0V1E1X4S0=0&N0&R2&I0&H1&A1B2&B0|
- Speed = 4800
- Disable EC = AT&M0|
- Set MNP4 = AT&M4&K0|
- Set MNP5 = AT&M4&K1|
- Hardware MNP
- ------------------------
- USR Courier 2400 Plus
- Init = ATQ0V1E1X2S0=0&I1B0F0&M0&C1&D2&K2&A0|
- Speed = 4800
- Disable EC = AT&E0|
- Set MNP4 = AT&E1*E0|
- Set MNP5 = AT&E1*E1|
- Hardware MNP
- ------------------------
- USR Courier HST
- Init = AT&C1&D2Q0V1E1X4S0=0&B1&N0&R2&I0&H1&A3|
- Speed = 19200
- Disable EC = AT&M0|
- Set MNP4 = AT&M4&K0|
- Set MNP5 = AT&M4&K2|
- Hardware MNP
- ------------------------
- USR Courier HST Dual Standard
- Init = AT&C1&D2Q0V1E1X4S0=0&B1&N0&R2&I0&H1&A3|
- Speed = 38400
- Disable EC = AT&M0|
- Set MNP4 = AT&M4&K0|
- Set MNP5 = AT&M4&K2|
- Hardware MNP
- ------------------------
- USR PCMCIA modem
- Init = ATB0F0E1V1X4&K3&C1&D2|
- Speed = 19200
- Disable EC = AT%C0\N0|
- Set MNP4 = AT%C0\N3|
- Set MNP5 = AT%C3\N3|
- Hardware MNP
- ------------------------
- USR Sportster 14400 Fax Modem
- Init = AT&C1&D2S0=0Q0V1&A3&B1&H1&I0&K3&R2|
- Speed = 38400
- Disable EC = AT&M0|
- Set MNP4 = AT&M4&K0|
- Set MNP5 = AT&M4&K2|
- Hardware MNP
- ------------------------
- Zenith Quad (Supersport Portable)
- Init = ATQ0V1E1X1&C1&D2&I1S7=255|
- Speed = 9600
- Disable EC = AT\N0|
- Set MNP4 = AT\N3|
- Set MNP5 = AT\N3|
- Hardware MNP
- ------------------------
- Zoom 2400 V42bis
- Init = ATX4E1Q0V1&C1&D2S0=0&K3W2|
- Speed = 9600
- Disable EC = AT&Q0|
- Set MNP4 = ATS46=0&Q5|
- Set MNP5 = ATS46=2&Q5|
- Hardware MNP
- ------------------------
- ZyXEL U-1496 and U-1496E
- Init = ATB0E1M1N5Q0V1X5S0=0&B1&C1&D2&H3&M0&N0&P1&S1|
- Speed = 38400
- Disable EC = AT&K0|
- Set MNP4 = AT&K1|
- Set MNP5 = AT&K4|
- Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
- Hardware MNP
- ------------------------
-