  1.  
  2.       Readme File for the Hewlett-Packard HP-GL/2 Windows Driver
  3.       ----------------------------------------------------------
  4.  
  5.  
  6. Product name:    HP Printer Driver
  7. ------------     (HP-GL/2 and HP RTL)
  8.          for Microsoft Windows.
  9.  
  10. Version number: v2.1
  11. --------------
  12. Language(s) supported: English, French, Italian, German, Spanish
  13. ---------------------
  14. Products supported:     HP DesignJet
  15. ------------------      HP DesignJet 200
  16.             HP DesignJet 220
  17.             HP DesignJet 230
  18.             HP DesignJet 250C
  19.             HP DesignJet 600
  20.             HP DesignJet 650C
  21.             HP DesignJet 750C
  22.             HP DesignJet 755CM
  23.  
  24. Installation instructions: See detailed instructions at the end of  
  25. -------------------------  this file.
  26.  
  27. Platform requirements:  MS Windows 3.1 or later.  MS Windows 95
  28. ---------------------
  29.  
  30.  
  31.  
  32. SOFTWARE APPLICATION NOTES:
  33. --------------------------
  34. The following section details late-breaking news regarding the use 
  35. of this driver with some popular software applications.
  36.  
  37. Aldus Freehand 4.0 users
  38. --------------------------
  39.    If the user works with another application while Freehand is 
  40.    printing, the printing may be aborted.
  41.  
  42.    To avoid this problem, do not use Windows until the Freehand 
  43.    printing has finished.
  44.  
  45. Aldus PageMaker version 5.0
  46. -------------------------------------
  47.    Problem:  The colors for some area fills are converted to solid 
  48.    colors.
  49.    Solution: Update to version 5.0a of the program.
  50.  
  51. Corel application users
  52. ------------------------
  53.    In CorelDraw 5.00.D1 and earlier versions, a floating point 
  54.    division by 0 exception can occur if you try to plot 5EFFECTS.CDR 
  55.    and others drawings with A1 and landscape settings. This problem 
  56.    has been fixed in any newer version of CorelDraw. Upgrade to 
  57.    CorelDraw! 5.00.E2 or any later version (if you are unsure about 
  58.    your current CorelDraw! version, click on "About" in "Help").
  59.  
  60. Lotus 123 users
  61. ---------------
  62.    When using this application you may see characters which overlap 
  63.    each other on the right side of the page.
  64.    Try using the 'Process document in computer' option. It may fix 
  65.    the problem. 
  66.  
  67. Micrografx Picture Publisher 5.0
  68. --------------------------------
  69.    When printing from this application, set the checkbox 'Use printer 
  70.    screening' in the print dialog box in order to get maximum quality 
  71.    color reproduction from your HP DesignJet printer. 
  72.    If you don't select this option and you print a long axis plot, you 
  73.    may see a black rectangle covering all, or part, of your drawing. 
  74.  
  75.  
  76.  
  77. Non-application-specific information:
  78.  
  79. (1)  Using 'Process document in computer' option
  80. ------------------------------------------------
  81.    If this processing mode is used with the printer connected 
  82.    to a local PC port, using the Print Manager spooler is 
  83.    strongly recommended. 
  84.  
  85. (2)  TRUE TYPE FONTS: problems with italic, rotated characters
  86.  -------------------------------------------------------------
  87.    If you use italicized and rotated text in your document and your 
  88.    printed output is not the same as you can see on your screen, check 
  89.    that you are using a font which is an actual TrueType font. 
  90.  
  91.    Workaround (a): choose a TrueType Italic Font which is listed in the 
  92.    Control Panel's "Fonts" dialog box.
  93.   
  94.    Workaround (b): use the 'Process document in computer' option when 
  95.    you print.
  96.  
  97. (3)  Excessive "Application lock-out" time (Win 95)
  98.      ----------------------------------------------
  99.    If you find that you are locked out of your application for an 
  100.    excessive amount of time when you send a file to be printed, it could be 
  101.    because "Enhanced MetaFile spooling" has been disabled.  This problem can
  102.    be caused by an old version of Adobe Type Manager (ATM), even if it is 
  103.    disabled.  We recommend that you upgrade to the latest version of ATM.
  104.  
  105. (4)  Adobe Type Manager (ATM) fonts: problems with large characters
  106. -----------------------------------------------------------------
  107.    If you use large characters from an ATM font and there are errors
  108.    in your printed output, choose one of the following options:
  109.  
  110.    Workaround (a): select the 'Print ATM fonts as graphics' option
  111.    in the ATM Control Panel.
  112.  
  113.    Workaround (b): use the 'Process document in computer' option when 
  114.    you print.
  115.    
  116.  
  117. INSTALLATION INSTRUCTIONS
  118. ------------------------- 
  119.  
  120.              IMPORTANT 
  121.      No other applications should be running when you 
  122.             install this driver.
  123.  
  124.  
  125. Quick Installation from Windows 3.1
  126. -----------------------------------
  127. 1. Insert the driver disk into the A (or other) drive of your 
  128.    computer.
  129. 2. In the Program Manager, select File and then Run...
  130. 3. On the Command Line, type a:\install and click on OK.
  131. 4. Select the desired configuration in the Installation dialog 
  132.    box and click on OK.
  133.  
  134. Quick Installation from DOS (Windows not running)
  135. ---------------------------
  136. 1. Insert the driver disk into the A (or other) drive of your 
  137.    computer.
  138. 2. Type:    win a:\install.
  139. 3. Select the desired configuration in the Installation dialog 
  140.    box and click on OK.
  141.  
  142. Standard Windows 3.1 Installation
  143. ---------------------------------
  144.  1. Insert the driver disk into the A (or other) drive of your 
  145.     computer.
  146.  2. Open the Program Manager in MS Windows.
  147.  3. In the Program Manager, select Main.
  148.  4. In Main, select Control Panel.
  149.  5. In Control Panel, select Printers.
  150.  6. In the Printers dialog box, click on Add Printer >>.
  151.  7. In the List of Printers list box, double click on the Unlisted 
  152.     Printer entry.
  153.  8. In the Add unlisted printer dialog box, double click on the
  154.     A: (or other) drive in the Directories list box.
  155.  9. Double click on the model name of the printer you want to install
  156.     in the "Printer model" list box.
  157. 10. Click on Use Print Manager.
  158. 11. In the Printers dialog box, click on Connect.
  159. 12. In the Printers - Connect dialog box, click on the desired
  160.     port.
  161. 13. In the Printers - Connect dialog box, change both the
  162.     Device Not Selected and Transmission Retry timeouts to 900
  163.     and click on Fast Printing Direct to Port. Click on OK
  164. 14. Double click on the desired installed printer so it appears
  165.     in the Default Printer box. Click on Close.
  166.  
  167.  
  168. Standard Windows 95 Installation
  169. --------------------------------
  170.  
  171. The driver you have received was written for a pre-release version of 
  172. Windows 95.  For this reason you are recommended to contact customer 
  173. support to ensure that you have the latest version of the driver.  
  174. Refer to the Customer Support section on page 7 of this driver's
  175. "Installation Guide" for details.
  176.  
  177. Note that, unless stated otherwise, all mouse clicks in the following 
  178. procedure assume you are using the left mouse-button.
  179.  
  180. 1. With the "HP Printer Driver (HP-GL/2 and HP RTL) for Microsoft 
  181.    Windows 3.1 and Windows 95" disk inserted in your floppy drive and 
  182.    with Windows 95 running, click on Start, select Settings and then 
  183.    Printers to open the Printers dialog box.
  184.  
  185. 2. Double-click on the Add Printer icon to open the Add Printer Wizard 
  186.    dialog box.
  187.  
  188. 3. Follow the steps displayed on your screen.  Below is a series of 
  189.    questions which, depending on your system configuration, you may be 
  190.    requested to answer.
  191.  
  192.    How is this printer attached to your computer? 
  193.    ----------------------------------------------
  194.    Select: 
  195.    Local printer if the printer is connected to your computer by a 
  196.    cable running directly between them.  
  197.    
  198.    Network printer if the printer has a network option installed, such 
  199.    as "The HP JetDirect Network Interface", and you will use it to 
  200.    communicate with your printer. 
  201.  
  202.    Do you print from MS-DOS-based programs? 
  203.    ----------------------------------------
  204.    We recommend that you select No, select Yes only in the case where you 
  205.    have an MS-DOS driver which can print to a HP DesignJet series printer.
  206.  
  207.    Would you like to print a test page? 
  208.    ------------------------------------
  209.    We recommend that you select Yes.  
  210.  
  211.    By printing a test page you will test the communications link between 
  212.    your system and the printer.
  213.  
  214. 4. At the end of the installation procedure you will see the Software Application 
  215.    Notes section of the driver's help system.  You are recommended to read the 
  216.    sections which apply to the applications which you use, after which you can 
  217.    close the help file and you will be returned to the Windows' 95 
  218.    "Add Printer Wizard" dialog box.
  219.  
  220. 5. Remove the driver installation disk. 
  221.  
  222.  
  223.  