Date: Fri, 15 Dec 1995 14:44:25 +0800
To: Manfred Recla <support@zyxel.co.at>
From: Mickey Tseng <mtseng@ZyXEL.HiNet.net>
Subject: Winfax Pro 4.0 Vs. Elite2864I ATI3
Dear all,
After implemented ATI3 for ISDN MODEM LINK STATUS REPORT,
it cause the problem in Winfax Pro 4.0. For Winfax will
request ATI3 (this is hardcoded) and expect OK from modem,
but you should know after ATI3, the modem will report all
the status in last call, but Winfax can not wait OK for a
such long time, and keep request +FMFR? This is the problem
why so many people report that they can not use WinFax after
ZyXEL Elite 2864I ISDN firmware v2.00 though they choose the
modem tpye "ZyXEL U-1496E+" and modify the initial string
to be correct one.
After deleting the I3 in the "wfxmod.exe" by debugger, now
it can work again.
Mickey Tseng
Electronic greeting from ZyXEL Taiwan
+--------------------------------------------------------------+
| Mickey Tseng E-Mail: mtseng@zyxel.hinet.net |
| Marketing Department Phone: 886-35-783942 |