home *** CD-ROM | disk | FTP | other *** search
/ Chip 2004 November / CMCD1104.ISO / Software / Complet / F-Prot / PROBLEM.TXT < prev    next >
Text File  |  2004-03-10  |  2KB  |  46 lines

  1. Currently, the following problems are known to the developers of F-PROT:
  2.  
  3. #1 Problem with long file names
  4.  
  5.    F-PROT for DOS has support for long file names when running under 
  6.    Windows '98.  Under Windows NT and later versions, F-PROT for DOS
  7.    might not be able to access some files with long file names.  This
  8.    is not a flaw in F-PROT as such - the same limitation applies to any
  9.    other DOS application.  
  10.  
  11.    The Windows version of F-PROT and the command-line fpcmd.exe program do
  12.    not have this limitation.
  13.  
  14. #2 Problem running F-PROT on some IBM ThinkPad models. 
  15.  
  16.    Some users of IBM ThinkPad machines have experienced a total failure of
  17.    F-PROT (DOS version) to run on their machines.  The reason is the
  18.    following: We use the CauseWay DOS extender program to create the DOS
  19.    version.  The ThinkPad models in question run some programs from
  20.    SystemSoft, including one named CARDXTND.SYS, which uses an old 16-bit
  21.    DOS extender from Rational, which is simply not compatible with
  22.    applications made with other DOS extenders.  In effect, while
  23.    CARDXTND.SYS is running, no CauseWay application (or for that matter,
  24.    application using other extenders) can be run, not even a simple "Hello
  25.    World" program.
  26.  
  27.    This problem also exists with older Zenith Data Systems notebooks that
  28.    also use SystemSoft BIOS and drivers. The executable PMEXT.SYS must be
  29.    in CONFIG.SYS for power management to function properly.
  30.  
  31.    There is nothing we can do to fix the problem, and we consider it
  32.    entirely the fault of SystemSoft - however, they have not yet (as of
  33.    Aug. 5th, 1998) responded to our E-mails regarding this issue.
  34.  
  35.    Until Systemsoft fixes the problem, CARDXTND.SYS must be disabled in
  36.    order to run F-PROT on those machines.
  37.  
  38. #1 Problem running F-PROT from a login script.
  39.  
  40.    We have received a single report of a problem that happens when F-PROT
  41.    is run from a login script, where the program may randomly "hang" some
  42.    time later.  We have not yet been able to duplicate this problem, but
  43.    we suspect it is due to a conflict with some device drivers or other
  44.    low-level software.
  45.  
  46.