- S B M F O R T R A N
-
- A FORTRAN answer to 'C'
-
-
-
-
-
- The best road is designed by the traveller.
-
-
-
-
-
-
- Copyright (c) 1989-1991 by
-
- DUKE DAIGH
-
- Pine Bluffs, Wyoming 82082-0631
-
-
-
- DISCLAIMER
-
-
-
- This is the initial release of SBM FORTRAN. It is probable that there
- are bugs. It may NEVER be totally bug-free. For this reason we make
- the following statement.
-
- This program is supplied as-is. The author disclaims all warranties,
- expressed or implied. The author assumes no liability for damages which
- might result from the use of this program.
-
- You are encouraged to freely distribute this package. Mail copies to
- friends. Put it up on other boards. We only request that you
- distribute only unmodified copies.
-
-
- Direct all inquiries, suggestions, etc. to:
-
- Duke Daigh
- P.O. Box 631
- Pine Bluffs, Wyoming 82082-0631
-
-
-
- CONTROL STATEMENTS
- TEST, TEST Numeric. . . . . . . . . . . . . . . . . . . . . 4-1
- Control flags . . . . . . . . . . . . . . . . . . . . . . . 4-1
- Conditional transfers . . . . . . . . . . . . . . . . . . . 4-1
-
- Compare variable to constant, CMP . . . . . . . . . . . . . 4-2
- Compare string to string . . . . . . . . . . . . . . . . . 4-2
- Unconditional transfers, GOTO, JMP . . . . . . . . . . . . 4-2
- WAIT . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
- PAUSE . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
- STOP, CALL EXIT . . . . . . . . . . . . . . . . . . . . . . 4-2
-
- TABLE_LOOKUP . . . . . . . . . . . . . . . . . . . . . . . 4-3
-
- IF statements . . . . . . . . . . . . . . . . . . . . . . . 4-4
- Block IF . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
- Do-loops . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
-
- RESERVED WORDS AND ARRAYS. . . . . . . . . . . . . . . . . . . . . 5-1
- The command line (command tail) . . . . . . . . . . . . . . 5-1
- Useful program constants . . . . . . . . . . . . . . . . . 5-1
-
-
- Miscellaneous Intrinsics . . . . . . . . . . . . . . . . . . . . . 6-1
- COPY Array_1 to Array_2 . . . . . . . . . . . . . . . . . . 6-1
- FIND_CHAR 'c', Array . . . . . . . . . . . . . . . . . . . 6-1
- END Ignored by the compiler. . . . . . . . . . . . . . . . 6-1
- Masking operations. AND, XOR, OR . . . . . . . . . . . . . 6-1
- SHIFT Shift a variable. . . . . . . . . . . . . . . . . . . 6-1
- PARSE String, Keword . . . . . . . . . . . . . . . . . . . 6-1
- PARSE_ONLY String, Keword, 'char' . . . . . . . . . . . . . 6-1
- LDA. Load address . . . . . . . . . . . . . . . . . . . . 6-2
- UPCASE. Convert string to upper case . . . . . . . . . . . 6-2
-
- SYSTEMS STUFF . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
- EXCLUDE_RTL . . . . . . . . . . . . . . . . . . . . . . . . 6-3
- LABEL variable, word/byte. . . . . . . . . . . . . . . . . 6-3
- PRESET data-type,variable . . . . . . . . . . . . . . . . . 6-3
- SETFORM 'c' . . . . . . . . . . . . . . . . . . . . . . . . 6-3
- SETIF 'c' . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
-
-
- Ramdisk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
-
- Known bugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1
-
-
-
- FEATURES OF SBM FORTRAN
-
- It is a compiler compiler. It was conceived as a bootstrap system to
- compile parts of itself. That's why I refer to it as my answer to 'C'.
-
- You can insert assembler coding and macros. You can invoke the standard
- interrupts. In other words, you can do anything with this compiler that
- you can do in assembler. In fact, some of the more complex modules of
- the compiler are WRITTEN IN FORTRAN. Any future refinements will be
- written in fortran.
-
- The executable module is very compact and efficient compared to other,
- higher-level compilers.
-
- It combines the simplicity of fortran coding with the power of the
- assembler.
-
- You can operate it as you would any other F77 compiler and end up with
- code that will usually run on any other F77 compiler.
-
- You can place more than one statement on each record.
-
- You can append comments to each statement.
-
- The compiled module uses buffered input, making it very fast.
- Pathnames are used so that you can access data on other drives and
- in other directories.
-
- All console/keyboard i/o can be re-directed.
-
- It has many powerful intrinsic operations, such as: PARSE, COPY,
- TABLE-LOOKUP, COMPARE, etc..
-
- You can do masking operations, such as AND, OR, XOR.
-
- You can shift variables left or right, by the number of bits that you
- specify.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- iv
-
- 1-1
-
- FORTRAN STATEMENTS
-
- There are two types of statements, executable and non-executable.
-
- Non-executable statements are used to describe the characteristics and
- format of data.
-
- Executable statements specify actions that the program is to take
- against, or for the welfare of the data, such as READ, WRITE, etc..
-
- Each source input line can be as long as 80 characters. Statement
- Continuations are permitted only on certain statements. they are:
- OPEN, FORMAT, data initialization.
-
- You can use statement labels to identify and reference individual
- statements in a program. You can label any statement but only labled
- statements can be referenced.
-
-
- SYMBOLIC NAMES AND KEYWORDS
-
- Symbolic names, chosen by the programmer, identify program variables and
- statement lables. A keyword is a pre-assigned identifier that you use to
- specify a particular action that the program is to take. Keywords are
- also known as RESERVED WORDs (see 5-1).
-
- A symbolic name is a sequence of one to 31 alphanumeric characters.
-
- When used to identify program variables, the first character must not be
- numeric. The name may consist of just about any printable character
- except for + - * / ( ) ; | apostrophy or comma. You cannot use reserved
- words to identify program variables.
-
- Standard fortran labels consist of numeric lables only. SBM fortran
- allows either, except for lables of format statements, which must begin
- with a numeric digit 0-9. Lables cannot begin with + - * ; |. Lables
- cannot use ( ) [ ] apostrophy or comma. Reserved words may be used as
- lables.
-
- Statement lables must begin in column 1. All other statements must begin
- in any column other than 1. By all means use column 7 if you wish to
- adhere to an accepted standard.
-
- You can assign more than one lable to a statement if you wish. In doing
- so, you can refer to it by either label.
-
-
- More than one statement may appear on each source input record by
- terminating each (except the last) with the marker code '|'. (on most
- keyboards this is uppercase backslash) The format of the additional
- statements is no different than the first, so don't forget to follow the
- marker with at least one blank, unless it is to be a label.
-
-
-
- STATEMENT ORDER
-
- Doesn't matter. mix or match. the compiler will sort them out.
-
- 1-3
-
- DATA TYPES
-
- * SBM provides three data types: BYTE, WORD and Doublewords.
-
- BYTE data occupies 8 bits (one byte) of memory and is normally only used
- for ascii characters and strings, or logical variables, such as
- programmer-specified switches and flags. You can use this data type for
- numerical values, up to 255.
-
- WORD data are numbers that are whole positive, negative or zero-value
- numbers. WORD data values occupy 16 bits (two bytes) of memory and can
- contain numbers from -32,768 to 32,767. Although a word can hold a number
- as large as 65,635, this implementation provides no standard way to
- output the larger numbers.
-
- * DOUBLEWORDs are 32-bit (integer*4) integers. The may contain numbers
- within the range -2,147,483,648 to +2,147,483,647. Integer*4 data is very
- useful for accounting applications where larger numbers are involved and
- precision is required in transactions. For example, monitary amounts can
- be set into integer*4 variables using total cents, rather than dollars
- and cents. When the results are to be printed, a special feature of
- integer*4 values allows you to insert decimal points where applicable.
-
-
- In SBM FORTRAN, the following mean the same:
-
- CHARACTER, BYTE, INTEGER*1, LOGICAL 8-bit data.
-
- INTEGER, WORD, INTEGER*2 16-bit data.
-
-
- CHARACTER strings appear in memory as a collection of ASCII characters
- terminated by a binary zero. This zero terminator controls all
- operations in which this data type is manipulated, such as compares,
- copys, input-output, etc.. With the terminator, this is known as as
- an ASCIIZ string.
-
-
-
-
- * Integer*4 is not totally implemented. Some parts of it are. Some not.
- I wouldn't recommend that you try it yet. It will be implemented in the
- next update.
-
- 1-5
-
- DATA DECLARATION and INITIALIZATION
-
-
- There are two modes in which you can declare variables, (1) declare and
- (2) declare/initialize.
-
- (1) Declare. The 'standard' declaration in which you specify the size
- of individual elements and optionally set aside a specific amount of
- memory to contain these elements in an array.
-
- Example: INTEGER ELEV(20), DIST(20), SLOPE, DELTA(3)
-
- (2) Declare/initialize. This mode allows you to declare a variable or an
- array and establish it's initial value(s). When initializing arrays, only
- as much memory as needed to contain the given data will be allocated.
- This statement can be continued. When used, this option must be the last
- (or only) declaration on the source statement. You can, of course, put
- multiple statements on one physical record. Examples:
-
- integer day/5/| integer month/12/| integer year/1948/
-
- integer*1 level(4), mace/3/
-
- character pathname/'c:sales.jan',0/
-
-
- This statement is tricky. If you forget the closing '/', the compiler
- will search the rest of your source looking for one.
-
- Here's another example, taken right out of the compiler itself:
-
- character registers/
- 'AX',0,'BX',0,'CX',0,'DX',0,'SI',0,'DI',0,'BP',0
- 'AL',0,'BL',0,'CL',0,'DL',0,'AH',0,'BH',0,'CH',0
- 'DH',0,'[SI]',0,'[DI]',0,'[BX]',0,'[BP]',0,'$'/
-
- If you want to declare an array of a certain size but initialize only the
- first portion, here's another example from the compiler:
-
- character outbuf(80)
- data outbuf/'e:sbm.t$$',0/
-
-
-
- THE DATA STATEMENT
-
- This is an executable statement! Most fortran reference manuals don't
- admit it but it is. Because of this fact, it can be used anywhere in
- the program. As you see above, you can initialize a variable or an
- array with it. You can also change data values on the fly. Over and
- over.
-
- Here's a handy use of this feature:
-
- If(code.eq.4) DATA table/1,2,3,4,5/
- If(code.eq.5) DATA table/6,7,8,9,0/
-
- 2-1
-
- OPEN statement
-
- The OPEN statement establishes the connection between a fortran UNIT and
- a file or device. You must issue this statement before any diskfile I/O
- can be used. Note: you cannot close a file and re-open.
-
- syntax:
-
- OPEN(UNIT,ALIAS=buff-name,FILE='filespec',status='old/new/append',
- RECL=nnn)
-
- where:
-
- UNIT is a numeric constant, in the range of 5-255.
-
- The unit number is converted to a control block name by appending the
- number to 'IOCB_'. The unformatted input record can be referenced by this
- name (as well as any alias that you may specify). Unit 10, for example
- may be referenced by the name 'IOCB_10'. An example of this can be found
- under UNFORMATTED READ.
-
- ALIAS is an alternate name by which the file can be addressed when
- reading unformatted (raw) data. Raw mode, when used instead of formatted
- or list-directed input results in much faster i\o. Unformatted i/o is
- discussed more fully in READ statements. This parameter is optional.
-
-
- FILE='filespec'. Pathnames can be used here. You may name a file that is
- to be used, or specify a character array which contains an ASCIIZ
- filespec. If the name itself is used here, it must be enclosed in quotes.
- If an array containing the filespec is used, it must not be quoted.
-
-
- STATUS='old/new/append'. If the file is to be created, use 'new'. If the
- file is to be read/write, use 'old'. If you have an existing file that is
- to be enlarged, use 'append'. If you use 'new', any existing file by that
- name will be replaced. If you omit this parameter, 'old' is assumed. The
- quotes are optional, for compatability.
-
-
- RECL=nnn. SBM uses a buffered input system, resulting in very high-speed
- input. The buffering system uses two arrays. one for the input buffer,
- (into which is loaded blocks of non-predictable pieces) and the record
- buffer which will contain only the individual record. It is from the
- record area that formatting takes place. You can use the RECL option to
- insure that no record exceeds a given size. If this option is omitted,
- record length defaults to 80.
-
- 2-3
-
- UNFORMATTED READ
-
-
- Syntax: READ(UNIT) list
-
- This is the most simple of the input statements. It transfers one
- record of binary data to the array 'list'. No conversion takes place.
- (A typical file of data information is stored as ASCII characters. No
- conversion is required if all you want to do is to examine it. It is
- considered to be binary data)
-
-
- If 'list' is omitted, one record is by-passed. For that reason it is
- sometimes referred to as a 'null' read, or 'by-pass' read.
-
- The contents of the record are available in the IOCB or under the ALIAS
- that was specified in the 'open'.
-
- Here's an example of how you might use it to read and display a file.
-
-
- open(5,file='reform.for')
- 1000 read(5)
- if(eof) stop
- write(*) iocb_5
- goto 1000
- end
-
- Type this one in and try it. It will make your hair stand on end! If you
- were to try this example on a large file, you can see that it wouldn't do
- you much good. The output would fly by so fast that you couldn't read
- most of it.
-
- 2-5
-
- WRITE STATEMENTS
-
- WRITE statements transfer data from memory to a specified I/O unit. You
- can reference both external and internal files.
-
- Syntax: WRITE(UNIT [,FMAT]) list
-
-
-
-
-
- UNFORMATTED WRITE
-
-
- Syntax: WRITE(UNIT) list
-
- This statement transfers one record of ascii data to UNIT. The data must
- be terminated by a binary zero. No formatting takes place.
-
- If 'list' is present, it must be the name of an array. If omitted, the
- formatted contents of the IOCB is written.
-
- This is the form of output that you should use to insert control
- characters, such as escape-sequences, extra line feeds, backspaces, etc.
-
- Example, from 'testall.for'
-
- data outbuf/esc,'[2J',0/
- write(*) outbuf ; clear the screen
-
-
-
-
-
- FORMATTED WRITE
-
- Syntax: WRITE(UNIT,FMAT]) list
-
- This is a two-step operation and is the revese of formatted read.
-
- Step 1 formats the specified data fields from binary to decimal as
- required and copies ascii data or quoted strings into the IOCB.
-
- Step 2 writes the contents of the IOCB to the specified UNIT.
-
-
- 2-7
-
- FORMAT STATEMENTS
-
- Format is a labled non-executable statement that specifies the format of
- data being transferred between memory and i/o devices. It may appear
- anywhere in the program. The first character of the label must be
- numeric. The method by which formatting takes place is by the use of
- field and edit descriptors with which the type and size of the various
- data fields is specified and quoted strings for constant ascii data.
-
- Each field descriptor consists of letter which identifies the type of
- data, followed by a number indicating the width of the data field. In
- some cases the width is optional.
-
- Format control proceeds from left to right, matching each field
- descriptor with each item in the i/o list.
-
- SBM uses 3 field descriptors, A, I, X
-
- Character data.
- The 'A' field descriptor transfers character data. It has the form
-
- A[w]
-
- If W is present the field width is w-characters. If omitted, the field
- width is the size of the data item in the i/o list. The name in the list
- can be any data type, character, logical or integer. On input, any
- existing data is simply overlayed.
-
-
- Integer data I[w]
-
- If the output binary number, when converted to decimal, exceeds the
- allocated space, the number will back-flow into the previous field,
- replacing whatever the formatter just put there. (not like standard
- fortran, which would fill the output field with asterisks. If enough of
- you complain, I will comply with the standard).
-
-
- Skip [w]x
-
- Quoted strings.
-
-
- Dollar sign descriptor $
-
- Normally, all output records are terminated by a carriage return. The
- dollar sign descriptor inhibits this action. The option is intended for
- interactive I/O and is valid only for output statements. It permits user
- response to appear on the same line as a prompt.
-
- example: WRITE(*,*) 'Enter project number: ',$
- READ(*,*) PROJ
-
- When used, the dollar sign descriptor must the the last item of the
- output statement.
-
- 3-1
-
- ARITHMETIC EXPRESSIONS
-
- SBM fortran does not yet support more than a simple one-function
- expression. The simpler form of an expression, while requiring more
- statements to complete some calculations, still maintains compatability
- with higher-level compilers.
-
- Thus, we are limited to such statements as:
-
- counter=counter+1
- range=limit-base
- etc..
-
- String expressions allow a little more versatility, such as:
-
- filespec='c:modemuf.asm'
- letter='A'
- etc..
-
-
- In addition to the above arithmetic statements, SBM fortran also supports
- the following statements:
-
- INC, DEC Add or subtract 1 from an integer variable. This is the
- most efficient way to add or subtract the constant 1 from
- a variable.
-
- example: inc counter ; add one to 'counter'
- dec tally ; subtract one from 'tally'
-
-
-
- ADD, SUB Add or subtract constant or value from register from an
- integer variable. This is much faster than standard
- fortran and uses less code.
-
- example: add index,10 ; add 10 to index.
-
- index=index+10 ; the usual, less
- ; efficient way.
-
-
-
-
- 4-1
-
- CONTROL STATEMEMTS
-
- There's no point in writing a program if you can't control what it does.
- Without flow control, a program would sequentially execute each of your
- statements and then blow up. That would be tacky.
-
- Fortran flow control statements provide a means of modifying the normal
- sequemntial flow of execution.
-
- Flow control statements are: TEST, COMPARE, CMP, DO, CONTINUE, GOTO,
- JMP, STOP and CALL EXIT. Some of these are not standard but all are
- handy.
-
-
-
- TEST
-
- Usage: TEST VARIABLE, MASK
- or TEST VARIABLE, NUMERIC
-
- You can test a variable using a mask, or TEST NUMERIC.
-
- When a TEST is performed, control flags are set, depending upon
- the results of the test. You must then use an if-statement or
- conditional jump. Control flags are: equal, not equal, zero,
- not zero, carry and not carry.
-
- (EQ), (NE), (ZR), (NZ), (CY), (NC), (NUMERIC), (NOT.NUMERIC)
-
- CONDITIONAL JUMPs are JNC, JC, JZ, JNZ
-
- Using a MASK, you can see if a particular bit or any one of a group
- if bits is set. It does this with a logical AND, and sets flags but
- changes nothing in memory.
-
- Example: see if an integer is odd or even.
- test(answer,1)
- if(zr) goto even
- (or) jz even
-
-
- To test an individual ascii character to determine whether it is
- numeric or not, use the following syntax:
-
- TEST VARIABLE, NUMERIC
-
- This checks an ascii character to see if it is within the range of
- '0' - '9'. As a result of this test, the logical variable 'numeric'
- is set to either true or false.
-
- Example: test(inbuf(1),numeric)
- if(not.numeric) goto alpha
-
- 4-3
-
- TABLE_LOOKUP
-
- Given a character string, tests to see if the string exists in a
- specified table. Each entry in the table must be enclosed within quotes
- and must be in upper case. each entry must be followed by binary zero.
- The table must be terminated by a '$'.
-
- If the given string is found to be present in the table, register CX
- indicates it's relative position in the array. i.e., in the table
- below, AX=1, BX=2, CX=3, etc.
-
- If the string cannot be found, CX=0 and carry-flag is set.
-
- Here's a sample table.
-
- character registers/
- 'AX',0,'BX',0,'CX',0,'DX',0,'SI',0,'DI',0,'BP',0
- 'AL',0,'BL',0,'CL',0,'DL',0,'AH',0,'BH',0,'CH',0
- 'DH',0,'[SI]',0,'[DI]',0,'[BX]',0,'[BP]',0,'$'/
-
- The following example wants to see if the character string that is in
- the array 'keword' is any of the entries in the table 'registers'.
-
- - see if a destination is register.
- table_lookup keword,registers
- if(nc) goto destin_ok
-
-
-
-
- TABLE_ADD
-
- Following a table-lookup operation, adds a string to a given table.
- While this is not a control statement, it is included here because it
- is frequently used immediately following a non-successful table_lookup.
-
- Example: install the string in the array 'keword' in the table.
-
- - new symbol, put it in table.
- table_add keword
-
-
- 4-5
-
- There are two types of IF statements:
-
- o The single IF
-
- o The block IF
-
- (The arithmetic IF is not supported by SBM fortran)
-
- The single IF statement conditionally executes a single statement. It
- has the form
-
- IF (exp) stmt
-
- where:
- exp is a logical expression.
-
- stmt is a single, not continued, fortran statement.
-
- 4-7
-
-
- There are two types of data which can be compared in an IF statement,
- numeric or literal. Literals are recognized by the presence of quotes.
- Here are some examples:
-
-
- * Author used the following program to test out and debug IF statements.
- integer ibuf
- write(*,*) 'enter a number: ',$
- read(*,*) ibuf
- if(ibuf.eq.100) then
- write(*,*) '---------------'
- write(*,*) 'number is equal'
- else
- write(*,*) 'number is NOT equal'
- endif
- if(ibuf.lt.100) write(*,*) 'number is LT 100'
- if(ibuf.le.100) write(*,*) 'number is also LE 100'
- if(ibuf.gt.100) write(*,*) 'number is GT 100'
- if(ibuf.ge.100) write(*,*) 'number is also GE 100'
- stop
-
- - - - - - - - - - - - - - - - - - - - - - - - -
-
- ; this program reformats a WASM LST file to straight ASM format. You
- ; might want to do this to have a source that has the macros expanded.
-
- open(5,file=infile,status='old',recl=132,alias=inbuf)
- loupe read(inbuf)
- if(eof) stop
- if(inbuf.eq.20h) goto loupe
- if(inbuf.eq.'L') goto loupe
- if(inbuf+22.eq.20h) goto loupe
- write(1) inbuf+26
- jmp loupe
-
-
- 5-1
-
- RESERVED KEYWORDS and ARRAYS
-
- FORTRAN has many keywords that are meaningful to the compiler, such as
- IF, READ, WRITE, etc.. In addition to the standard list of reserved
- keywords, SBM fortran includes some options not provided in other
- systems:
-
-
- LDA, EXCLUDE, WAIT, JMP, JNC, JC, JZ, JNZ, AND, XOR, OR, SHIFT,
- SETFORM, SETIF, SHOW_CHAR, INCLUDE, UPCASE, INC, DEC, TEST,
- ADD, SUB, CMP, LABEL, PARSE, COPY, NEXCHAR, TABLE_LOOKUP, TABLE_ADD,
- COMPARE, FIND_CHAR, CRLF, PRESET.
-
- YOU CANNOT USE RESERVED WORDS AS VARIABLE NAMES, although any of them
- may be used as statement lables.
-
-
- In addition to the above reserved words, we also have the following
- arrays, which are considered as reserved words:
-
- COMMAND, CONSOLE, INFILE, WORKBUF, OUTFILE, WORKBUF2.
-
-
-
- THE COMMAND LINE
-
- One of the problems facing the high-level programmer is how to access the
- data that we entered at the system prompt. SBM fortran sets this data
- where it can be easily used. The command tail can be located in the
- character array COMMAND. From there it can be parsed or otherwise used
- just like any other character array. In addition, the first two tokens
- are parse into INFILE (alias WORKBUF) and OUTFILE (alias WORKBUF2) and
- may be used as filenames in the OPEN statement.
-
- The advanced programmer will find these options to be of significant
- value.
-
-
- PROGRAM CONSTANTS
-
-
- Rather than using numerical equivalents for commonly needed constants,
- you may choose from the following list of pre-assigned symbolic names.
-
- CR Carriage return. Use instead of 0Dh, 13 decimal.
- LF Line feed. Use instead of 0Ah, 10 decimal.
- ESC Escape. For ansi screen control, 1Bh, 27 decimal.
- FF Form feed. To eject the page in printer files.
- TAB
- BS Back space.
- COMMA Equivalent to 2Ch.
- QUOTE Equivalent to 27h.
- QUOTES Equivalent to 22h.
- False Equivalent to binary zero.
- True Equivalent to binary 1.
-
- 6-1
- MISCELLANEOUS INTRINSIC FUNCTIONS
-
-
-
- COPY Array_1, Array_2
-
- Copies a character string to another array. Can be indexed.
-
-
-
-
- FIND_CHAR 'c', Array
-
- Searches a character string until the specified character is located.
-
-
- END Optional for compatability. Ignored by the compiler.
-
-
-
- AND, XOR, OR Masking operations
-
- Usage: AND variable,mask. Mask is hex constant, register, memory.
-
-
-
-
- SHIFT Shift a variable, left or right.
-
- Usage: SHIFT VARIABLE [,nbits]
-
- Shifts the variable the number of bits specified. If nbits absent, shift
- the variable one bit right. Otherwise you must specify the number of
- shifts. If nbits is preceded by a minus sign, shift is to the left.
-
- Example: shift 'number' one bit right.
- SHIFT NUMBER
-
- nother: shift 'number' 3 bits left.
- SHIFT NUMBER,-3
-
- If you wish to shift only one bit left, it can be more efficiently
- done by adding the number to itself. It accomplishes the same result.
-
- Example: ibuf=ibuf+ibuf
-
- or better yet: ax=ibuf
- add ibuf,ax
-
- 6-3
- SYSTEMS STUFF
-
- Things on this page are of no value to users. They are included here
- only for Author's convenience.
-
-
- LABEL variable, word/byte. Allows alias in system modules. Must be
- issued immediately before the data decalaration statement.
-
- PRESET data-type,variable Establish name and type in symbol
- table for external variable. data type is byte/word.
-
- SETFORM 'c' Change default character in format name. Normally
- fmt_nnn. Changes the 't'. Sample: fma_001.
-
- SETIF 'c' Change default character in if-labels. Normally
- true_000. Changes first '0'. Sample: true_a01.
-
- Example of the above two. SETFORM a| SETIF a
-
- 7-1
-
- Greater speed can be realized by using a ramdisk. To take advantage
- of this feature, include in your autoexec.bat file the following:
-
- SET RAMDISK=d
-
- Where 'd' is your ramdisk drive. i.e. SET RAMDISK=E
-
-
-
- In the batch files, notice the commands SET BATCH=TRUE and
- SET BATCH=.
-
- These two commands are used by the compiler to determine the course
- or action when the requested source file cannot be found. They are of
- no concern for normal operations and should not be disturbed.
-
-
- 8-1
- KNOWN BUGS
-
- I am aware of the following bugs. If I take time to correct them
- now, I may not get this system on the boards before I move to Wyoming.
- They will be addressed in the next update.
-
-
- 1. If you re-define a variable, you get no error message but all
- sorts of seemingly unrelated problems.
-
-
- 2. if(inbuf.eq.';') SBM.ASM(get_record)