home *** CD-ROM | disk | FTP | other *** search
- This file will detail changes made to SETUPWIZ.EXE after VB 3 shipped.
-
- To check the internal version number of your SETUPWIZ.EXE, open a copy
- of the file in an editor, and search for the string "ver:" This will
- show the version number. Visual Basic version 3.0 for Windows shipped
- with SETUPWIZ.EXE version 1.00.532.
-
- VERSION BUGS FIXED
- ---------------------------------------------------------------------
- 1.00.533 When using "Save Template", you must enter a file name
- with extension. The extension is no longer required.
- 1.00.533 The "max" setting for the horizontal scrollbar on the Step
- Five screen is so large that the middle button of the scroll
- bar really can't be used. The max has been reset to a smaller
- value.
- 1.00.533 The standard command .PIF file may not have the EXECUTION =
- EXCLUSIVE on some computers. As a result, the DOS shells for
- compressing files may sit in the background. Now shell with
- parameter makes the task active with focus.
- 1.00.534 Minor tweaks to the user interface to widen the TEMPLATE
- buttons, added an accelerator to the R in Rebuild, and changed
- the accelerator in Exit to the 'x' key.
- 1.00.535 Start SetupWiz. Enter C:\. Click NEXT. This causes an
- untrapped error: "Path/file access error".
- 1.00.536 Removed line FILE10=OLE2UI.DLL under the [MSOLE2.VBX]
- section in SETUPWIZ.INI.
- 1.00.536 Try using Setup Wizard to create setup disks for the
- OLE2DEMO sample application after removing the OLE2UI entry from
- SETUPWIZ.INI. In step 2, select OLE. The Next button
- doesn't work. The Back button does work, and the Next button
- works if nothing is selected in step 2. The Finish button also
- works. This problem affected any OLE application.
- 1.00.537 Selecting more than 40 files with the Common Dialog during
- ADD FILES was not handled before. Now it is.
- 1.00.538 Cleaned up the MSOLE2.VBX and OLE Automation sections in
- SETUPWIZ.INI
- 1.00.539 A PATH pointing to non-existing directories or drives resulted
- in a "User-defined error". Now Setup Wizard returns the correct error
- message and continues.
- 1.00.542 Fixed compression problems when running under Windows NT.
- 1.00.543 Fixed an invalid keyword in some common dialogs that asked
- where a file is located.
- 1.00.543 Fixed a problem if a template's .EXE file was deleted or moved.
- 1.00.544 SetupWizard incorrectly added VER.DL_ to the SETUP.LST file. Setup Wizard
- no longer adds this file to SETUP.LST.
-
- PROBLEMS/LIMITATIONS:
- 1) COMPRESS.EXE will only take a limited length command line. If SetupWizard is in a subdir that is
- nested too deep, then COMPRESS will not work properly. You will encounter a 'File does not exist'
- error when in actuality the file does exist. To work around this problem, move the SETUPKIT
- subdir up one or more directory levels until COMPRESS works.