home *** CD-ROM | disk | FTP | other *** search
- LANtastic (tm) LANCHECK Program Documentation
- ------------------------------------------
- (C) Copyright 1990 ARTISOFT Inc.
-
-
- Once the NETBIOS has been installed, you can be sure that
- the adapter is functioning. You cannot, however, be assured
- that the adapter can communicate with the network.
-
- There may be several reasons why an adapter is not
- communicating with the rest of the network. The most
- obvious cause is that the cabling is faulty or not connected
- correctly. Another reason may be that there has been a
- hardware failure on the adapter in the circuitry that is
- responsible for communication on the network.
-
- The distribution floppy disk that comes with your LANtastic
- Starter Kit contains a LAN diagnostic program (LANCHECK)
- which may be used to make sure that all adapter cards are
- functioning and connected together on the network. The
- LANCHECK program appears as LANCHECK.EXE on the distribution
- diskette.
-
- To run the program type:
-
- LANCHECK a-unique-name [/MONO]
-
- where a-unique-name is a unique name (up to 16 characters)
- that you wish your PC to be known by on the network. This
- name will be displayed on each computer running LANCHECK and
- allows you to monitor which computers are actively running
- LANCHECK.
-
- It is recommended that you bring up all your network nodes
- simultaneously to ensure that they are evaluated for
- performance during the same period. LANCHECK evaluates
- each node's performance from when it is first brought up on
- the network, not just from the time LANCHECK is executed.
- LANCHECK will test six adapter cards per computer (adapters
- 0 through 5) and can display a maximum of 1000 nodes. You
- can run LANCHECK any time after bringing up the NETBIOS, even
- after other LAN software is running.
-
- The most important test for the adapters is whether they all
- appear on the screen when LANCHECK is run. If an adapter is
- not listed on the LANCHECK screen, it is probably not
- communicating with the rest of the network.
-
- The optional switch /MONO forces the screen to run
- the LANCHECK program in monochrome (2 color) mode.
-
- Testing a Network Adapter
-
- After the NETBIOS software has been installed, type the
- following commands:
-
- LANCHECK a-unique-name
-
- For example,
-
- LANCHECK JOAN
-
- or
-
- LANCHECK BOB
-
- would be typical unique names.
-
- After an initialization message and a short pause (Note: the
- pause will be longer if you have multiple adapter cards
- attached), the LANCHECK screen will appear as shown:
-
- LANtastic (tm) LANCHECK Version 3.01 (C) Copyright 1990 Artisoft Inc.
-
- ╔═══════════════════════════════════════════════════════════════════════════╗
- ║ A# NAME NODE NUMBER MINUTES RUNNING STATUS ERROR INDEX ║
- ╠═══════════════════════════════════════════════════════════════════════════╣
- ║ 0 BOB 00006EA00029 9 (local) 2% ║
- ║ 0 JOAN 00006EA00045 9 active 2% ║
- ║ ║
- ║ ║
- ║ ║
- ║ ║
- ║ ║
- ║ ║
- ║ ║
- ║ ║
- ║ ║
- ║ ║
- ║ ║
- ║ ║
- ║ ║
- ║ ║
- ║ ║
- ║ ║
- ╚═══════════════════════════════════════════════════════════════════════════╝
-
- Enter - Select Entry, Esc - Exit Lancheck, Space - Update Screen, F1 - Help
-
- At any time while the LANCHECK program is running you may
- press the F1 key to receive more information about the
- fields presented in the screen. You can make the help
- window double in size by pressing the letter Z on the
- keyboard. Pressing Z a second time will change the help
- screen back to its original size. Use the arrow keys to
- scroll the text up and down, or use the PgUp or PgDn keys
- to move the text up or down a page.
-
- The screen updates itself every ten seconds, or when you
- press the SPACE BAR.
-
- "A#" tells you which adapter you are receiving information
- on . The first adapter is numbered "0," the second "1" and
- so on. Up to six adapters per computer may be tested.
-
- "NAME" refers to the unique node name you specified with
- the LANCHECK command. Check to make sure that all the
- adapter cards you are running LANCHECK on are listed in this
- table. If any are missing, you may have a cabling problem
- or a faulty adapter.
-
- "NODE NUMBER" denotes the unique network number assigned to
- the adapter. "Minutes Running" shows how long the adapter
- has been running since you installed the NETBIOS software. The
- "Status" field tells you whether the adapter being tested
- is active or inactive, and which adapters are "local,"
- (located on your computer). If an adapter that is supposed
- to be active lists as inactive, there may be a problem with
- the adapter or the cabling to that adapter. If you see an
- adapter with a status that keeps switching between "Active"
- and "Inactive" there is probably an intermittent problem
- with the cabling.
-
- The Field "ERROR INDEX" presents you with a statistic to
- help you deduce the relative performance of each adapter in
- the sending and receiving of network data. The values given
- in the example above should not be considered an average or
- ideal value for the adapters you are evaluating. Look
- instead for adapters that have ERROR INDEX values that are
- either much higher or lower than the other adapters in your
- network. An adapter with a much higher ERROR INDEX might have a
- cabling problem or other hardware problem. Low values might
- indicate the node is able to receive data correctly, but is
- not properly transmitting data to the rest of the network.
- This will increase the other nodes' ERROR INDEX scores
- because they will be receiving bad transmissions from the
- faulty adapter.
-
- To further evaluate the efficiency of a network node, use
- the arrow keys to move the highlight bar to the desired node
- and press ENTER. This window will appear:
-
-
- LANtastic (tm) LANCHECK Version 3.01 (C) Copyright 1990 Artisoft Inc.
-
- ╔═══════════════════════════════════════════════════════════════════════════╗
- ║ A# ╔══════════════════════════════════════════════════════════════╗ INDEX║
- ╠═════║ Adapter Status of: JOAN ║══════╣
- ║ 0 ╠══════════════════════════════════════════════════════════════╣ ║
- ║ 0 ║ Adapter Number: 0 ║ ║
- ║ ║ Node Number: 00006EA00045 ║ ║
- ║ ║ Software Version: 2.10 ║ ║
- ║ ║════════════════════════════════╤═════════════════════════════║ ║
- ║ ║ TRAFFIC AND ERROR STATISTICS │ ADAPTER RESOURCE STATISTICS ║ ║
- ║ ║────────────────────────────────┼─────────────────────────────║ ║
- ║ ║ Minutes Running: 9 │ NCBs Available: 26 ║ ║
- ║ ║ CRC Errors: 222 │ NCBs Allocated: 32 ║ ║
- ║ ║ Alignment Errors: 320 │ Max NCBs Possible: 128 ║ ║
- ║ ║ Collisions: 9 │ Active Sessions: 4 ║ ║
- ║ ║ Bad Transmissions: 65 │ Sessions Allocated: 32 ║ ║
- ║ ║ Good Transmissions: 3928 │ Sessions Possible: 128 ║ ║
- ║ ║ Good Receives: 23103 │ Max Packet Size: 2461 ║ ║
- ║ ║ Retransmissions: 65 │ Number of Names: 8 ║ ║
- ║ ║ Resource Exhaust: 838 │ ║ ║
- ║ ╚══════════════════════════════════════════════════════════════╝ ║
- ║ ║ ║
- ╚═══════════════════════════════════════════════════════════════════════════╝
-
- Esc - Exit Status Window, Space - Update Data, F1 - Help
-
- The information at the top of the window tells you the name
- of the node, adapter number and node number being tested as
- well as the version of the LANCHECK software you are using.
- The bottom left portion of the screen provides you with
- "Traffic and Error Statistics" which may help you diagnose
- a hardware problem with you network. To the right of this
- are the "Adapter Resource Statistics" which provide
- information concerning your NETBIOS configuration.
-
- Once again, do not assume that the values presented in the
- example above are the same values that you should see. What
- you should look for instead are values that are out of the
- average range for the rest of your adapters.
-
- Traffic and Error Statistics
-
- The field "Minutes Running" refers to the length of time
- since the NETBIOS was run.
-
- Cyclical Redundancy Check (CRC) errors occur when a packet
- of data arrives at a node in a corrupt form. Before a
- computer sends a packet, it mathematically evaluates the
- contents of the packet and places this information in it.
- The receiving node performs the same calculation on the data
- as it receives it then matches it against the results of the
- sending node's evaluation. If the results don't match, the
- receiving node asks the sending node to retransmit the
- packet.
-
- A high value in the "CRC" field could indicate that an
- adapter is not correctly transmitting data. It might also
- indicate faulty cabling or electrical noise is corrupting
- the data in transit.
-
- Alignment errors occur when bits of data arrive out of the
- 8-bit group they were sent in. These bits must then be
- regrouped into their original bytes by the receiving node.
- While this does not usually degrade network performance, a
- high value in this field could indicate cabling or hardware
- problems.
-
- Network collisions occur when two or more nodes attempt to
- access the network simultaneously. A high value here will
- usually indicate a busy network. In rare cases, however, a
- malfunctioning adapter will continuously transmit noise
- resulting a higher number of collisions.
-
- The fields, "Good Transmissions" and "Bad Transmissions"
- provide you with statistics for successful and unsuccessful
- transmissions. Busier networks will have more unsuccessful
- transmissions than networks with less frequent use. A high
- number of Bad transmissions could indicate a faulty adapter.
- "Retransmissions" occur after unsuccessful transmissions.
- Once again, look for values that are significantly higher
- than the rest of the nodes.
-
- A low value for "Good Receives" could indicate that an
- adapter is not receiving network data well. In such cases,
- it is best to test this node with only a few other adapters
- and make sure this low value is not a result of poor
- transmissions from an adjoining network node.
-
- When a node exhausts its supply of buffers, it can no longer
- receive data from the network. The field "Resource Exhaust"
- keeps count of each time this happens. If your node is
- continually running out of buffers, it may be advisable to
- set your buffers higher to better accommodate your network
- traffic.
-
- If you suspect that there is a hardware problem and an
- adapter has a higher than average value in one or more of
- the above categories, remove the node from the network and
- see how network performance changes. If performance goes up
- dramatically the adapter could be at fault.
-
- Adapter Resource Statistics
-
- The values given in this field can help you evaluate how
- well your software configuration meets your network needs.
- For example, if you don't have enough Network Control Blocks
- (NCBs), to process data and commands in and out of the
- adapter, network performance will suffer, or some network
- software will not run.
-
- If the field "NCBs Available" has a value less than eight
- you should consider raising the number of NCBs allowed for
- this adapter. You can set this with the NETBIOS command
- line switches. A good way to estimate the number of NCBs you
- need is to take the number of log ins you will need and add
- eight.
-
- The "Max NCBs Allocated" field informs you how many are
- allocated in the NETBIOS command line. The maximum
- number of NCBs available depends on the NETBIOS.
-
- A session is created any time a connection between two nodes
- is made or attempted to be made. If the number given in the
- "Active Sessions" seems out of proportion with what you
- feel it should be, check your software to make sure it is
- configured for the proper number of sessions. The maximum
- number of sessions available depends on the NETBIOS.
-
- "Max Packet Size" refers to the largest size data packet
- that this adapter can either send or receive. The Maximum
- size of a data packet depends on the size of the buffers set
- for the adapter.
-
- The field "Number of Names" refers to the number of network
- names currently being used. An adapter with a much larger
- value than the other adapters may be running a program that
- is erroneously creating a large number of names.
-
- To check a second node, press Esc to exit to the previous
- window then select the node you want to test and press
- ENTER.
-
- You can also check the adapter status of any network node by
- pressing Ins while in the first LANCHECK window. A screen
- will appear asking you for the name of the node you want to
- test. Type in the name exactly as it used by the node in
- question, then press ENTER. Normally you will use all
- capital letters. The "Adapter Status" window for the
- desired node will appear. Repeat this process for each
- adapter you want to evaluate. To exit the LANCHECK program
- from the main window, press the Esc key.
-