home *** CD-ROM | disk | FTP | other *** search
- Number: A1TH081390U307
- Subject: ELS II v2.15 NCR PC-8 Machine Problem
- Date: September 13, 1990
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
-
- PROBLEM: A customer reported a problem running ELS-II v2.15
- non-dedicated on a NCR PC 8 machine. They got the error
-
- "Problem with drive 00. Error reading disk redirection
- information. Error reading NetWare configuration
- information."
-
- when they tried to boot up ELS-II v2.15 non-dedicated on a
- NCR PC 8 machine.
-
- They tried the ISADISK kit for ELS, but they still got the
- same error. They tried three different controllers and two
- or three different drives. They even tried three different
- RAM boards. If they generated a dedicated server,
- everything worked fine.
-
- SOLUTION: They replaced the BIOS in the machine with the current
- Phoenix BIOS and it worked.
-
- (X) This information was verified verbally.
-
-