home *** CD-ROM | disk | FTP | other *** search
- Number: A2TH081790U363
- Subject: Set Maximum Packet Size Larger
- Date: September 21, 1990
- - - - - - - - - - - - - - - - - - - - - - - - - - -
-
- PROBLEM: A customer was running NetWare 386 v3.1 on a Compaq 386
- SystemPro. The SystemPro had one of Compaq's 32 bit Token-
- Ring cards in it.
-
- The problem they had was that none of their AT machines
- could copy a binary file to the file server. They would get
- a "Network error". All of their XTs or microchannel
- machines worked fine. All of their workstations are running
- at 16 Megabits. The above problem only occurred with binary
- files.
-
- SOLUTION: The solution to the problem was to set the "Maximum Receive
- Physical Packet Size = 4202" in the STARTUP.NCF file.
-
- (X) This information was verified verbally.
-
-