home *** CD-ROM | disk | FTP | other *** search
- SEAGATE TECHNOLOGY, INC.
- Technical Support Bulletin Board
- 408/438-8771 [300-9600 HST, MNP 3/5, N-8-1]
- (C)opyright 1990
-
- ST-4038
-
- /─4─3─2─1─\
- │ O O O O │ Power
- └─────────┘
- ┌Data Cable 1 5 G G 12
- ═════════ ══ ════════════════════ ═══ ════════════
- o o o o o o o o ┌1 └Controller Cable
- o o o o o o o o ││
- Drive Select->1 2 3 4 │ │ │ │ │├─ Resistor Termination Pack
- │ │ │ │ │ │ │ ││
- │ └┬┘ │ │ │ │ └┘
- │ │ │ │ │ │
- │ │ │ │ │ │
- │ │ │ │ │ └ Radial
- │ │ │ │ └── Recovery Mode
- │ │ │ └──── Write Fault
- │ │ └────── Not Connected
- │ └───────── Never Used (Drive Select 3 and 4)
- └ If twisted cable, use Drive Select 2
-
- ST - 4038
-
- UNFORMATTED CAPACITY (MB) ________________38.2
- FORMATTED CAPACITY (17 SECTORS) (MB) _____31.9
- ACTUATOR TYPE ____________________________VOICE COIL
- TRACKS ___________________________________3,665
- CYLINDERS ________________________________733
- HEADS ____________________________________5
- DISCS ____________________________________3
- MEDIA TYPE _______________________________OXIDE
- RECORDING METHOD _________________________MFM
- TRANSFER RATE (mbits/sec) ________________5.0
- INTERFACE ________________________________ST412
- TPI (TRACKS PER INCH) ____________________750
- BPI (BITS PER INCH) ______________________9,617
- AVERAGE ACCESS (ms) ______________________40
- SINGLE TRACK SEEK (ms) ___________________8
- MTBF (power-on hours) ____________________25,000
- POWER REQUIREMENTS: +12V START-UP (amps) _4.0
- +12V TYPICAL (amps) __1.5
- +5V TYPICAL (amps) ___1.5
- TYPICAL (watts) ______25.5
- MAXIMUM (watts) ______56
- BUFFERED STEP PULSE RATE (micro sec) _____10-70
- WRITE PRECOMP (cyl) ______________________300
- REDUCED WRITE CURRENT (cyl) ______________N/A (734)
- LANDING ZONE (cyl)________________________AUTO PARK
- IBM AT DRIVE TYPE ________________________22, 20 or 8
-
- Seagate reserves the right to change, without notice, product
- offerings or specifications. (6/26/90)