- XA Command Interpreter
-
- Version 01.04
-
- August 1991
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- Copyright 1991 by Bruce Christensen
- All rights reserved.
-
-
-
-
-
-
-
-
-
-
- Table of Contents
-
- 1 Introduction.................................................... 3
-
- 2 Installation.................................................... 4
-
- 3 XA - the X10 Command Interpreter................................ 4
-
- 4 XA Tokens....................................................... 7
-
- 4.1 XA Token Reference............................................ 7
-
- 4.2 Tokens in detail.............................................. 8
-
- 4.2.1 Action Tokens (ON, OFF, DIM)................................ 8
-
- 4.2.2 Module Address Tokens (HOUSE, UNIT, A1...P16)............... 10
-
- 4.2.3 Coordinate Tokens (LATITUDE, LONGITUDE, TIMEZONE)........... 11
-
- 4.2.4 Clock Tokens (SYNCHRONIZE X10, PC, EXACT)................... 12
-
- 4.2.5 Day Tokens (SUNDAY...SATURDAY, WEEKDAYS, WEEKENDS, etc.) ... 13
-
- 4.2.6 Date Tokens (DATE, THRU).................................... 13
-
- 4.2.7 Time Tokens (TIME, SUNRISE/SET, OFFSET, NORMAL,
- SECURITY, RANDOM)............................. 15 15
-
- 4.2.8 Misc Tokens (BASECODE, PORT, DEFINE, EVENT, CLEAR, DIAGNOSE,
- MONITOR, IRQ, IO, LOG, ERASE)............................ 17
-
- 5 Command Files................................................... 20
-
- 6 Monitoring and Logging Events................................... 21
-
- 7 POWERUP Utility................................................. 23
-
- 8 License Agreement and Registration.............................. 24
-
-
-
- XA Command Interpreter (Version 1.04) Page 3
-
-
- 1) Introduction
-
- This floppy contains a set of extremely useful DOS utilities for the
- X10 Computer Interface (CP290). These utilities are being marketed
- under the try-before-you-buy (Shareware) concept to allow you a
- complete test of the product before you are required to register.
- Shareware provides you with low-cost, high-performance software and
- support. Many features have been added to this product based on input
- from users. Registration will provide you with the latest updates, and
- an opportunity to voice your suggestions for new product features. See
- Section 8.0 - License Agreement and Registration, also the
- Registration form for more details.
-
- To take full advantage of the features in this package, you
- should connect your computer to an X10-compatible Appliance module.
- This way, the combination of the X10 hardware and the XA software can
- take "home automation" to a higher level. From now on, you can have
- the CP-290 update itself on once-per-week basis. These updates may
- include events that may be scheduled days, months, even years in
- advance.
-
- There are (2) two programs distributed on this disk. Briefly,
-
- A) XA - X10 Command Interpreter. (XA.EXE)
- This utility reads and downloads commands to the CP290 in
- two modes. The first mode is from command line arguments,
- ie, from the DOS prompt. The second mode can read an entire
- file of commands. These commands can be either timed events
- or direct commands.
-
- Besides these functions, the interpreter has several
- features not found with the original X10 software. Some of
- these features are:
-
- 1) Exact Sunrise/Sunset times based on the latitude,
- longitude, and timezone of your city.
-
- 2) Request any event to occur days, months, even years
- from now. XA expands X10's time base by allowing you
- to program an event for any day in the future, or
- you can schedule an event to occur between two
- defined dates.
-
- 3) Synchronize your PC's clock with the time maintained
- by the CP-290, or synchronize the CP-290 clock with the
- time maintained by your PC. These settings can be
- made down to the second, so both your PC and CP-290
- are exactly synchronized.
-
- 4) Monitor events as the CP-290 executes them, and
- optionally log them to a file.
-
- 5) The ability to change the base housecode without
- losing all the data already stored in the interface.
-
- XA Command Interpreter (Version 1.04) Page 4
-
- 6) String substitution in the command file allows you
- to equate a device (FAMILY_ROOM_LAMP) with its module
- address (A3).
-
- 7) Comments are allowed in the file to properly document
- its content.
-
- 2) POWERUP - AUTOEXEC Time Check Utility
- This utility is provided for those of you that control your
- computer with an X10 Appliance module. When placed in your
- AUTOEXEC.BAT file, this utility compares the current PC time
- with a pre-set time "window" that you define. During your
- computers powerup, if the PC's time falls within this
- "window", it will return an errorlevel of 1. This errorlevel
- can then be checked and used to perform any number of
- functions you desire. For instance, X10 turns my computer on
- at 3:00 AM every Sunday morning. POWERUP checks the
- computers time and then invokes a complete optimization and
- backup of my hard drives as well as downloads updated times
- to the X10 Computer Interface. There will be more on this
- subject in Section 7 - Powerup Utility.
-
-
-
- 2) Installation
-
- You probably want to copy the contents of this floppy to the same
- drive and directory in which your X10 software resides. It's also a
- good idea to include this drive and directory within your PATH
- statement of the AUTOEXEC.BAT file.
-
- Ex: SET PATH=C:\DOS;D:\X10;...
-
- You should set the XA environment variable to the drive and directory
- of your command files. This also can be placed in your AUTOEXEC.BAT
- file.
-
- Ex: SET XA=D:\X10
-
- (See the AUTOEXEC.BAT supplied with this package for an example).
-
-
-
- 3) XA - The X10 Command Interpreter
-
- As stated earlier, XA can operate on commands from the DOS command
- line, or from a file. In either mode, XA uses several options to alter
- its operation. The XA command has the following form:
-
- ┌───────────────────────────────────────────────────────────────────┐
- │ XA [f=filename] [c=comm port] [i=irq] [o=io_addr] ["commands"] │
- │ [-e] [-s] [+m] [+h] │
- └───────────────────────────────────────────────────────────────────┘
-
- XA Command Interpreter (Version 1.04) Page 5
- The options may appear in any order, but the presence of some of these
- options negates other options.
-
- [f=filename] - this is the name of the file containing the
- commands to be interpreted by XA. To use XA in
- its file mode, you would type:
-
- XA f=filename
-
- The default file name is XA.CMD. If you want to
- use the default file, you do not have to specify
- the filename - just type: XA
-
- [c=comm port] - this allows you to select the serial port for
- communications with the interface. You may
- select ports 1...4. For example, if your CP290
- is connected to COM3:
-
- XA c=3
-
- The default port is 1. To use the default, you
- do not have to specify the port number - just
- type:
-
- XA
-
- See Section 4.2.7 - Miscellaneous tokens for a
- different way to set the comm port within a
- command file. Also, see the next two options if
- your comm port uses a different IRQ level, or a
- different IO port address.
-
- [i=irq] - use this option if your communications port uses
- a different IRQ level than what is "standard"
- (see Section 4.2.7 - PORT COMx for the default
- assignments). The default IRQ level is 4. If
- your serial port uses IRQ 5, then include:
-
- XA i=5
-
- [o=io_addr] - this option allows you to select a different IO
- address from the default 3F8 hex. If your serial
- port is setup for 2E8 hex, then use:
-
- XA o=2E8
-
- XA Command Interpreter (Version 1.04) Page 6
- ["commands"] - "commands" consist of several tokens (huh? - see
- Section 4 - Tokens) that describe an event of
- direct command. For example:
-
- XA "A1 ON"
-
- In the above example, A1 and ON are tokens.
- Together they form a single command. Multiple
- commands may appear in the command line, but
- they must be enclosed by quotation marks (" ").
- The next example shows the use of multiple
- commands to create a flashing effect:
-
- XA "A1 ON" "A1 OFF" "A1 ON" "A1 OFF"
-
- One other note, the presence of any commands on
- the command line will nullify the use of a file.
- Therefore in the next example, the XA utility
- will ignore the file request and process just
- the commands:
-
- XA f=null.cmd "A1 A2 A3 A4 ON"
-
- [-e] - this option is used to prevent any
- communications to the interface. Use this option
- only when you want to validate commands in a
- file.
-
- [-s] - this option is used to prevent sorting the
- commands based on their EVENT numbers (see
- EVENTS described in Section 4.2.8 -
- Miscellaneous tokens).
-
- [+m] - this option will monitor the comm port for any
- events reported by the CP-290. Press the <ESC>
- key to terminate. Note: You can run this as a
- background task in Windows 3.0 (386 enhanced
- mode) to avoid tying up your computer.
-
- [+l] - this option will append any monitoring
- information to the file XA.LOG. The [+m] option
- must also be specified for this command to work.
-
- [+h] - displays a brief summary of the options
- described above.
-
-
- XA Command Interpreter (Version 1.04) Page 7
- 4) XA Tokens
-
- What are tokens?
- A token is to a command as a word is to a sentence. Individual words
- are constructed to form a complete sentence - tokens are constructed
- to form complete commands. This section will describe each token that
- is recognized by the interpreter. Often, tokens may appear
- anywhere in the command. For example, the command
-
- XA "A1 ON" may also be constructed as
- XA "ON A1"
-
- In other instances, tokens must sometimes be arranged in groups, and
- their order is important. For example, the command to set your PC's
- internal clock to the time that is maintained by the CP290 is:
-
- XA "SYNCHRONIZE PC" <---This is legal
-
- If the tokens SYNCHRONIZE and PC were reordered as in the following
- command:
-
- XA "PC SYNCHRONIZE" <---This is illegal
-
- The interpreter would respond with a message indicating the token it
- did not recognize along with the line number it appeared in. Then it
- displays the entire line that contains the error:
-
- WARNING: Unrecognized token "PC" in line 1.
- PC SYNCHRONIZE
-
- Therefore, throughout this documentation any tokens that must be
- arranged in a certain order will be contained in curly braces {..}.
- Other tokens may be optional and will contained in parentheses (..).
-
-
- 4.1) Token Reference
-
- The following is a list of available tokens. Tokens that must be
- arranged in a certain order will be contained in curly braces {..}.
- Other tokens that may be optional will be denoted in parentheses (..).
- All these tokens will discussed in more detail in the next section:
-
- 4.1.1 Action tokens -
- ON - turns ON the specified modules.
- OFF - turns OFF the specified modules.
- {DIM %%} - DIM to a % (percentage) level of brightness.
-
- 4.1.2 Module address tokens
- {HOUSE x} - module HOUSEcode A...P
- {UNIT z} - module UNITcode 1...16, ALL
- A1...P16 - HOUSE UNIT combined
-
- 4.1.3 Coordinate tokens:
- {LATITUDE d m} - your LATITUDE in Degrees and Minutes
- {LONGITUDE d m}- your LONGITUDE in Degrees and Minutes
- {TIMEZONE x} - your TIMEZONE (Standard/Daylight Savings time)
-
- XA Command Interpreter (Version 1.04) Page 8
-
- 4.1.4 Clock tokens:
- {SYNCHRONIZE PC (EXACT)} - set PC time based on X10 time
- {SYNCHRONIZE X10 (EXACT)} - set X10 time based on PC time
-
- 4.1.5 Day tokens:
- SUNDAY, SUN - Specific day for event to occur
- MONDAY, MON - "
- TUESDAY, TUE - "
- WEDNESDAY, WED - "
- THURSDAY, THU - "
- FRIDAY, FRI - "
- SATURDAY, SAT - "
- EVERYDAY - Event occurs everyday
- TODAY - Event occurs once today only
- TOMORROW - Event occurs once tomorrow only
- WEEKDAYS, WEEKDAY - Event occurs only on weekdays
- WEEKENDS, WEEKEND - Event occurs only on weekends
-
- 4.1.6 Specific Date tokens:
- {DATE mm/dd/yyyy} - Event occurs on specified date
- {DATE mm/dd/yyyy THRU mm/dd/yyyy}
- - Event occurs between two dates
-
- 4.1.7 Time tokens:
- {TIME hh:mm AM} - Schedule event time
- {TIME hh:mm PM}
- SUNRISE - Calculate time of sunrise
- SUNSET - Calculate time of sunset
- {OFFSET +/-mm} - Event + or - 60 mins of programmed time (dawn)
- NORMAL - Event occurs at specified time
- SECURITY,RANDOM - Event occurs within the hour of programmed time
-
- 4.1.8 Miscellaneous tokens:
- {BASECODE x} - change house BASECODE of interface to A...P
- {PORT COMx} - send commands via PORT COM1..4
- {IRQ x} - customize IRQ level for port.
- {IO x} - customize port address (must be in hex).
- {DEFINE x z} - substitute string 'x' for string 'z'
- {EVENT xxx} - Place event xxx in a known location of CP290 memory
- DIAGNOSE - Invoke CP290 self-test routine
- MONITOR - Watch events as the CP290 executes them
- LOG - Append event info to file XA.LOG
- {CLEAR EVENT xxx} - Clear (delete) event xxx from CP290 memory
- ERASE - Erase ALL events from CP290 memory
-
- 4.2) Tokens in Detail
-
- 4.2.1 Action Tokens
-
- ON
- This token informs the interface to turn ON the selected
- modules.
-
- Example: XA "A1 ON"
-
-
- XA Command Interpreter (Version 1.04) Page 9
-
- OFF
- This token informs the interface to turn OFF the selected
- modules.
-
- Example: XA "A1 OFF"
-
-
- {DIM %%}
- These two tokens specify the intensity level of the selected
- lamp module or wall switch module. The modules will turn on,
- brighten to full intensity, then dim to the percentage
- specified in the second token. There are 16 different
- brightness levels available, the percentage you choose
- (0 to 100) is mapped to one of these levels. See Note 3
- below for compatibility issues with X10.EXE.
-
- Example: XA "A1 DIM 50"
-
-
-
- Notes:
-
- 1) Only one token in this category should appear in a command. If
- two or more of these tokens appear, only the last one will be
- acted on. For example:
-
- XA "A1 ON OFF" - will be interpreted as:
- XA "A1 OFF"
-
- If you were trying to flash the lights, the proper way to
- perform this action is:
-
- XA "A1 ON" "A1 OFF"
-
- 2) You may activate as many modules as you want in a single
- command providing these modules share the same HOUSE code:
-
- XA "A1 A2 A3 A4 A5 A6 ON"
-
- To activate modules with different HOUSE codes, use separate
- commands:
-
- XA "A1 A2 A3 ON" "B1 B2 ON" "C1 OFF"
-
- 3) If you download a timed event that contains the DIM token, the
- X10 interface program (X10.EXE) reports the DIM level @ 90%,
- even though you may have the level at some other intensity.
- The reason for this discrepency is because X10.EXE stores a
- mirror image of the data it sends to the CP-290 (along with
- some other information) in a file called X10.DAT. Eventually,
- when the exact format of this file is determined, XA will be
- able to create a similar file so that the proper levels
- will be displayed by X10.EXE. Any of you hackers out there
- that know this format, please step forword.
-
-
- XA Command Interpreter (Version 1.04) Page 10
-
- 4.2.2 Module Address tokens
-
- {HOUSE x}
- These two tokens specify the HOUSE code of the module you
- want to select. There are 16 HOUSE codes available, lettered
- A through P. This method of selecting address requires the
- use of the UNIT token. Only one HOUSE token should appear in
- a command.
-
-
- {UNIT y}
- {UNIT ALL}
- These two tokens specify the UNIT code of the module you
- want to select. There are 16 UNIT codes available, numbered
- 1 through 16. Specifying UNIT ALL operates on all 16 modules
- addressed by the HOUSE token. This method of module
- addressing requires the use of the HOUSE token.
-
- Examples: XA "HOUSE A UNIT 1 ON" or,
- XA "UNIT 1 HOUSE A ON"
-
- Multiple UNITs may appear in a single command.
-
- Example: XA "HOUSE A UNIT 1 UNIT 2 UNIT 3 ON"
-
- Turn off all units on HOUSE P.
-
- Example: XA "HOUSE P UNIT ALL OFF"
-
- A1...P16
- This is a shortcut method of specifying both HOUSE and UNIT
- tokens. The house code must appear first, followed by the
- unit code. Specifying ALL is not permitted.
-
- Example: XA "A1 ON" "P16 OFF"
-
- Notes:
-
- 1) You may activate as many modules as you want in a single
- command providing these modules share the same HOUSE code:
-
- XA "A1 A2 A3 A4 A5 A6 ON"
-
- To activate modules with different HOUSE codes, use separate
- commands:
-
- XA "A1 A2 A3 ON" "B1 B2 ON" "C1 OFF"
-
-
- XA Command Interpreter (Version 1.04) Page 11
- 4.2.3 Coordinate tokens
-
- This group of tokens enable the precise calculation of sunrise
- and sunset times for your location. This information can be
- found in almanacs, or extrapolated from maps. Your local library
- or city hall may also have the precise coordinates. If your
- events don't require these functions, then don't worry about
- them.
-
-
- {LATITUDE d m}
- Your LATITUDE in degrees (0...+/-90) and minutes (0...59).
-
- Example: LATITUDE 41d35m
-
-
- {LONGITUDE d m }
- Your longitude in degrees (0...+-180) and minutes (0...59).
- Longitudes West of the prime meridian are positive, those
- East of the prime meridian are negative. In the US, all
- longitudes are positive.
-
- Example: LONGITUDE 81d20m
-
-
- {TIMEZONE x}
- Exact calculations depend on the local time. Use the
- following table to determine your time zone.
-
- Zone x
- ==================== =========
- Eastern Standard Time: 5
- Eastern Daylight Time: 4
- Central Standard Time: 6
- Central Daylight Time: 5
- Mountain Standard Time: 7
- Mountain Daylight Time: 6
- Pacific Standard Time: 8
- Pacific Daylight Time: 7
-
- Example: TIMEZONE 5
- Notes:
-
- 1) Since all three tokens in this group are required for sunrise
- and sunset calculations, it is easier to include these tokens
- in a file and invoke the XA utility in the file mode:
-
- Example: XA f=rise_set.cmd
- where the file "rise_set.cmd" contains the following
- commands:
- :
- LATITUDE 41d35m
- LONGITUDE 81d20m
- TIMEZONE 5
- :
-
-
- XA Command Interpreter (Version 1.04) Page 12
- 2) Remember to change TIMEZONE to the value that's appropriate
- during the Spring and Fall when the time is adjusted.
-
- 4.2.4 Clock tokens
-
- {SYNCHRONIZE PC (EXACT)}
- These tokens instruct the XA utility to set your computers
- clock based on the current time retrieved from the CP290. It
- will not affect the computers date.
-
- Example: XA "SYNCHRONIZE PC"
-
- Use the optional "EXACT" token to wait for the X10 time to
- rollover to the next minute. This provides a synchronization
- within 1 second, but forces you to wait for up to one minute
- for this rollover to happen.
-
- Example: XA "SYNCHRONIZE PC EXACT"
-
- {SYNCHRONIZE X10 (EXACT)}
- These tokens instruct the XA utility to set the time and day
- of the CP290 internal clock based on the current time
- retrieved from your computer.
-
- Example: XA "SYNCHRONIZE X10"
-
- Using "EXACT" will force XA to wait until the PC's clock
- seconds counter rolls over from 59 to 00 ensuring a
- synchronization of clocks to within 1 second, however you
- may have to wait for up to 1 minute for this rollover to
- happen.
-
- Example: XA "SYNCHRONIZE X10 EXACT"
-
- Notes:
-
- 1) You might want to include the command:
-
- XA "SYNCHRONIZE PC"
-
- in your AUTOEXEC.BAT file to set your PC's internal clock if
- your system lacks a on-board battery backed-up clock. Note
- that this command will not set up the date since X10 does not
- contain a real-time calendar.
-
- 2) Use:
- XA "SYNCHRONIZE PC" or,
- XA "SYNCHRONIZE X10"
-
- in your AUTOEXEC.BAT file if either your PC or CP290 do not
- keep accurate time.
-
- XA Command Interpreter (Version 1.04) Page 13
- 4.2.5 Day tokens:
-
- Use of these tokens indicate a timed event, ie, the complete
- command will be downloaded to the interface and stored there for
- later activation.
-
- SUNDAY, SUN
- MONDAY, MON
- TUESDAY, TUE
- WEDNESDAY, WED
- THURSDAY, THU
- FRIDAY, FRI
- SATURDAY, SAT
- These tokens specify the specific day of the event. Multiple
- tokens may appear within a command.
-
- Example: XA "MONDAY FRIDAY A1 ON TIME 7:30 AM"
-
- WEEKENDS, WEEKEND
- Event occurs on SATURDAY and SUNDAY
-
- WEEKDAYS, WEEKDAY
- Event occurs MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY
-
- EVERYDAY
- Event occurs MON TUE WED THU FRI SAT SUN
-
- TODAY
- Event will occur today only at the specified time. It is
- then deleted from the interface after midnight.
-
- TOMORROW
- Event will occur tomorrow only at the specified time. It is
- then deleted from the interface after midnight.
-
-
- Notes:
-
-
- 4.2.6 Specific Date tokens:
-
- Since the CP-290 does not contain an on-board calendar, there is
- no direct method of storing an event that occurs more than 1 week
- away. However, XA has the ability to evaluate dates and as long
- as XA is run at least once a week it can determine the
- appropriate time to download the event. This feature allows you
- specify an event weeks, months, or years in advance. In addition,
- you can specify an event to occur on specific days of each month
- (such as every 10th day of the month), or annually (every 4th of
- July), or an event may be scheduled to trigger every day between
- specific dates (such as Christmas and New Years).
-
- If you plug you computer into an Appliance module, you can have
- the CP-290 turn your computer on automatically on a once-per-week
- basis. By using POWERUP.EXE (supplied with this package) you can
- have a new set of events automatically downloaded to the CP-290.
-
- XA Command Interpreter (Version 1.04) Page 14
- Now you'll never forget to update your CP-290 - your computer
- does it for automatically. This is what "automation" is all
- about. Also, this method guarantees that specific dates will be
- evaluated and events will be triggered at the proper time in the
- future. See Section 7.0 on the Powerup utility for more details.
-
-
- VERY IMPORTANT NOTE:
-
- When using the following DATE tokens, you should include the
- "ERASE" token in your command file. ERASE will clear the entire
- contents of the CP-290, removing all event information. The
- reason you want to erase its memory is because once XA downloads
- an event to the CP-290, it will remain there until it is deleted
- or overwritten. The next time XA is run (next week) the event may
- still remain and trigger itself again and again until it is
- either manually deleted, or eventually overwritten by a new
- event. ERASE ensures that the data is cleared and that the
- interface will contain fresh information. Also, since all your
- information is stored in a command file, the relavent information
- will always be placed in the CP-290.
-
-
-
- {DATE mm/dd/yyyy}
- Event occurs on specified date. You must specify the date in
- the following format:
-
- Month - 0, 1, or 2 digits (1 = January... 12 = December)
- Day - 0, 1, or 2 digits
- Year - 0, or 4 digits (1991 - NOT 91).
-
-
- To specify module A5 to turn on July 4, 1992 at 5:00 pm:
-
- A5 ON DATE 7/4/1992 TIME 5:00 PM
-
- You may omit fields which is the equivalent of specifying
- any month, day, or year. Each field must be delineated by a
- seperator, either a '/' or '-' character. For example, to
- specify module A5 to turn on every 4th of July at sunset,
- leave off the "yyyy" field:
-
- DATE 7/4/ A5 ON SUNSET
-
- To specify module A5 to turn off on the 4th of every month
- at 6:00 AM
-
- DATE /4/ A5 OFF TIME 6:00 AM
-
-
- Use DEFINE statements to clarify certain dates (see Section
- 4.2.8).
-
- DEFINE CHRISTMAS_DAY DATE 12/25/
- A1 ON CHRISTMAS TIME 5:00 AM
-
- XA Command Interpreter (Version 1.04) Page 15
-
-
- {DATE mm/dd/yyyy THRU mm/dd/yyyy}
- Event occurs between two dates. Use the same conventions as
- described above.
-
- If you will be going on vacation between July 1, 1992 and
- July 17, 1992, and you want the bedroom lights (A3) turned
- on and off in a random fashion during the evenings:
-
- DATE 7/1/1992 thru 7/17/1992 ON A3 TIME 9:00 PM SECURITY
- DATE 7/1/1992 thru 7/17/1992 OFF A3 TIME 11:30 PM SECURITY
-
- Use DEFINE statements for clarification, and reduce typing
- for multiple entries (note that both uppercase and lowercase
- is used):
-
- DEFINE Vacation DATE 7/1/1992 THRU 7/17/1992
- DEFINE BEDROOM_LIGHTS A3
- DEFINE ON_EVENING TIME 9:00 PM SECURITY
- DEFINE OFF_NIGHT TIME 11:30 PM SECURITY
- :
- Bedroom_Lights On_Evening Vacation
- Bedroom_Lights OFF_Evening Vacation
-
-
-
-
- 4.2.7 Time tokens:
-
- Use of these tokens indicate a timed event, ie, the complete
- command will be downloaded to the interface and stored there for
- later activation.
-
- {TIME hh:mm AM}
- {TIME hh:mm PM}
- Schedule event at a certain time.
-
- Example: XA "SUNDAY ON TIME 12:30 AM D1"
-
- SUNRISE
- SUNSET
- These tokens will calculate the sunrise or sunset for the
- day token in the command. The use of these tokens also
- requires the LATITUDE, LONGITUDE, and TIMEZONE tokens to be
- included. Therefore, these tokens should be used in the file
- mode.
-
- Example: MONDAY ON SUNSET D1
-
- If multiple day tokens appear in the command line, the
- sunrise or sunset will be calculated for the last day token
- that appears in the command line.
-
- Example: MONDAY TUESDAY WEDNESDAY ON SUNSET D1
-
-
- XA Command Interpreter (Version 1.04) Page 16
- If more accuracy is needed, then break each daily event into
- its own command.
-
- Example: MONDAY ON SUNSET D1 EVENT 0
- TUESDAY ON SUNSET D1 EVENT 1
- WEDNESDAY ON SUNSET D1 EVENT 2
-
-
- {OFFSET +-mm}
- Push or postpone the scheduled event by up to 60 minutes.
- This token is useful if you want to activate lights at dusk
- rather than sunset, or to deactivate lights at dawn rather
- than sunrise. The '+' sign is the default condition, you
- must specify the '-' if needed.
-
-
- Example: Turn on lights 30 minutes after sunset
- MONDAY ON SUNSET D1 EVENT 0 OFFSET 30
-
- Turn lights off 45 minutes before sunrise
- MONDAY OFF SUNRISE D1 EVENT 1 OFFSET -45
-
- See Section 4.2.8 (Miscellaneous Tokens) for another way of
- specifying DUSK or DAWN. This can be accomplished using the
- "DEFINE" token. For example:
-
- DEFINE DUSK SUNSET OFFSET 30
- DEFINE DAWN SUNRISE OFFSET -45
- :
- MONDAY ON DUSK D1 EVENT 0
- MONDAY OFF DAWN D1 EVENT 1
-
-
- XA Command Interpreter (Version 1.04) Page 17
-
- NORMAL
- This token activates the event at the specfied time. It is
- the default mode, therefore it does not need to be
- specified.
-
- SECURITY
- RANDOM
- This token allows the interface to randomly select the
- activation time of the event. This activation occurs within
- the hour of the programmed time. Therefore, if the
- downloaded time was for 7:18 PM, actual activation time
- could range from 7:00 PM through 7:59 PM. This mode provides
- a security feature giving your lighting a more lived-in
- look.
-
- Example: XA "A1 ON TIME 7:30 PM SECURITY EVERYDAY"
- XA "A1 ON TIME 7:30 PM RANDOM EVERYDAY"
-
-
- 4.2.8 Miscellaneous tokens:
-
- {BASECODE x}
- These tokens change the base housecode of the interface
- WITHOUT losing the data stored in the interface. Prior to
- changing the housecode, a complete upload of all events
- stored in the interface is performed. The housecode is
- changed, then all events are downloaded back into the
- interface. Valid housecodes are A...P.
-
- Example: XA "BASECODE D"
-
- During upload, the interface sends all 128 possible events
- that are stored in its memory. If an event actually exists,
- then an up arrow is displayed, otherwise a dot (·) is
- displayed. During download, a down arrow is displayed.
- Downloads will take significantly longer due to the overhead
- involved with sending synch bytes for each event.
-
- {PORT COMx}
- These tokens allow you to specify which comm port the
- interface is attached to. Legal ports are:
-
- COM1 = I/O address 0x3F8 Interrupt 4
- COM2 = " 0x2F8 " 3
- COM3 = " 0x3E8 " 4
- COM4 = " 0x2E8 " 3
-
- These tokens were intended to be placed in command files.
- They will take precedence over the 'c=x' command line
- argument (see section 3).
-
- Example line in a command file:
- PORT COM3
-
-
- XA Command Interpreter (Version 1.04) Page 18
- If your port assignments do not match those in the above
- table, then use the command line parameters [i=x] and
- [o=xxx], or the file mode tokens "IRQ" and "IO" (see below)
- to customize the communication characteristics.
-
- {IRQ=x}
- Use these tokens in your command file only if your
- communications port uses a different IRQ level than what is
- "standard" (see the above table for the default
- assignments). The default IRQ level is 4. If your serial
- port uses IRQ 5, then use the following line in your command
- file:
-
- IRQ=5
-
- These tokens were intended to be placed in command files.
- They will take precedence over the 'i=x' command line
- argument (see section 3).
-
- {IO=x}
- This option allows you to select a different IO address from
- the default 3F8 hex. If your serial port is setup for 2E8
- hex, then use the following line in your command file:
-
- IO=2E8
-
- These tokens were intended to be placed in command files.
- They will take precedence over the 'o=x' command line
- argument (see section 3).
-
-
- {DEFINE x z}
- These tokens were designed to be used in command files. They
- allow you to substitute several tokens into a single token
- of your choice. They help to make command files more
- readable. Up to 50 custom tokens are allowed. For example,
- you can assign a token "CHRISTMAS_ON" to an equivalent group
- of tokens "HOUSE A UNIT 4 ON TIME 8:00 PM EVERYDAY" as
- follows:
-
- DEFINE CHRISTMAS_ON HOUSE A UNIT 4 ON TIME 8:00 PM EVERYDAY
- ============ =======================================
- x z
-
- The 'x' and 'y' strings can be up to 60 characters each.
- Notice that the 'x' portion uses underscore characters (_)
- to separate the words but to keep the string contiguous.
- This is important because the XA interpreter looks for a
- SPACE character to separate the 'x' and 'y' components.
-
- Later in the command file, you can use the following command
- to activate your Christmas lights:
-
- CHRISTMAS_ON
-
- XA Command Interpreter (Version 1.04) Page 19
- Internally, XA will convert this string to its equivalent:
- HOUSE A UNIT 4 ON TIME 8:00 PM EVERYDAY
-
- More Examples:
- :
- DEFINE PLANT_GROW_LIGHTS A8
- DEFINE OUTSIDE_LIGHTS A1
- DEFINE ALL_ON HOUSE A UNIT ALL ON
- :
- PLANT_GROW_LIGHTS ON TIME 6:00 AM EVERYDAY
- PLANT_GROW_LIGHTS OFF TIME 12:00 AM EVERYDAY
- :
- OUTSIDE_LIGHTS OFF SUNRISE EVERYDAY
- :
- ALL_ON SUNDAY TIME 7:30 PM
-
- The use of DEFINES is helpful if you want to the XA utilty
- monitor the CP290 for events as they occur. See Section 6 on
- Monitoring.
-
- **** Important Note ****
- DEFINEs must be declared before being used. The following
- would cause an error message because the DEFINE was placed
- out of order:
-
- OUTSIDE_LIGHTS ON SUNSET EVERYDAY
- DEFINE OUTSIDE_LIGHTS A1
-
- {EVENT xxx}
- The CP290 can store up to 128 events in its memory. Each
- event occupies fixed locations in memory. When you download
- events to the interface, an event number will be assigned to
- the command. The first event will have an event number of 0,
- the second will be 1, etc. Therefore, any event that was
- previously stored at those locations will be overwritten.
- The token {EVENT xxx} allows you to override the number
- assigned to this command.
-
- If you normally use one command file then the need to use
- this token is probably unnecessary. If multiple command
- files are used, then this token is helpful.
-
- Example: MON ON SUNSET D1 EVENT 100
- TUE ON SUNSET D1 EVENT 101
- WED ON SUNSET D1 EVENT 102
-
-
- {CLEAR EVENT xxx}
- These tokens delete the specified event from the computer
- interface. See description for EVENT xxx above. Only 1 event
- may be cleared per command.
-
- Example: XA "CLEAR EVENT 100" "CLEAR EVENT 101"
-
- XA Command Interpreter (Version 1.04) Page 20
- ERASE
- This token erases all events from the CP-290 memory. Use
- this token when specific dates are present in your command
- file. This way, once the date has come and gone, it will be
- deleted from the CP-290 memory automatically.
-
- DIAGNOSE
- This token triggers the X10 diagnostic routine. You will be
- informed of the results after a few seconds.
-
- ┌────────────────────────────────────────────┐
- │ *** WARNING ***: │
- │ │
- │ The diagnostics on the CP290 will │
- │ destroy all the event information stored │
- │ in its memory. Make sure you have all │
- │ the event information contained in a │
- │ command file so that you can restore │
- │ this data once the diagnostics have │
- │ completed. │
- └────────────────────────────────────────────┘
-
- MONITOR
- This token informs XA to continuously monitor the
- communications port for any messages sent by the CP290 when
- it executes a stored event. See Section 6 - Monitoring and
- Logging Events for more information.
-
- LOG
- This token appends the monitored information in the file
- XA.LOG. You must also specify either MONITOR in the command
- file or +m on the command line for this action to occur. See
- Section 6 - Monitoring and Logging Events for more
- information.
-
-
- 5) Command files
-
- Since the CP290 is only capable of storing a single weeks worth of
- events, command files were created to allow easy update of the events
- that may need to revised due to ever-changing conditions, such as
- sunrise and sunset times. Also specific date information may be
- contained within this file. XA has the capability to interpret these
- dates and update the CP-290 accordingly.
-
- Command files should only be created with an editor or word processor
- that saves files in pure ascii format. Any extraneous characters or
- control codes will cause the XA interpreter to ignore your commands.
-
- You may place comments in your command file. A comment is delineated
- by the pound sign character '#'. This character must appear in the
- first column of the line.
-
- # This is an example comment.
-
- XA Command Interpreter (Version 1.04) Page 21
- Comments are ignored by the interpreter. Therefore, comments can be
- placed in front of commands you do not want to download to the
- interface at this time. For example, you can hide your Christmas
- lighting commands from the interpreter once the holidays are over:
-
- #DEFINE XMAS HOUSE A UNIT 2
- #XMAS ON EVERYDAY SUNSET OFFSET 20
- #XMAS OFF WEEKDAYS TIME 10:00 PM
- #XMAS OFF WEEKENDS TIME 12:00 AM
-
- Hint: Use the DATE tokens to to ensure that your lighting is only
- activated at certain times of the year.
-
- Blank lines are permitted in the command file. These allow you to
- group similar events together.
-
- See the sample command file "XA.CMD" (included in this package) I use
- for automating events in my home.
-
- XA defaults to reading a command file if there are no commands in the
- in the command line. The default command file is called 'XA.CMD'. You
- may keep a number of command files around. To use a different command
- file, use the 'f=' parameter when starting XA. For example, if you
- wanted to execute the commands found in a file called 'MONITOR.CMD',
- you would start the XA utilty as:
-
- XA f=MONITOR.CMD
-
- The next section discusses the use of monitoring and logging events,
- and uses a command file called MONITOR.CMD to show how this is done.
-
-
- 6) Monitoring and Logging events
-
- The CP290 sends a message to your computer after it executes an event
- stored in its memory. Most software packages (including X10.EXE
- shipped with the CP-290) will ignore these messages. XA allows you to
- monitor as well as log these events if desired.
-
- XA will enter its monitor mode after all other commands have been
- processed. You can activate the monitor feature in two ways, as a
- command, or as a command line parameter.
-
- Command example:
- XA "MONITOR"
-
- Command line parameter example:
- XA +m
-
- In the first example, XA "MONITOR", the command MONITOR informs XA to
- watch for any transmissions from CP290. The second example use command
- line options and has the same effect, but remember that if no commands
- were actually present, the XA utility will try to open the command
- file 'XA.CMD' and process the commands found in there. If you don't
- want that to happen, use the '-e' option which tells XA not to execute
- (or download) those commands. See the next example:
-
- XA Command Interpreter (Version 1.04) Page 22
-
- XA +m -e
-
-
- When XA begins to monitor, it displays the following message:
-
- Monitor events. Press <ESC> when finished...
-
- XA waits for a message from the CP290. You may exit this function by
- pressing the <ESC> key.
-
- When the CP290 executes an event it sends a message to the PC with the
- following information; the HOUSE code, UNIT code, and the event
- FUNCTION (ON, OFF, DIM). XA takes this information and adds the time
- and date information from your PC's clock and prints the following
- message:
-
- Sun Mar 24 07:00:13 1991 HOUSE A UNIT 5 ON
-
- This message is semi-useful; it describes what just occurred but if
- you forgot what was addressed as HOUSE A UNIT 5 then the message is
- pretty meaningless. You can give this module a more descriptive name
- by using a command file that includes DEFINE statments for all your
- modules. Below is sample command file (MONITOR.CMD) that describes
- what we're talking about:
-
- DEFINE Porch/Garage_Lights HOUSE A UNIT 1
- DEFINE Plant_Grow_Lights HOUSE A UNIT 5
- DEFINE Family_Room_TV HOUSE A UNIT 6
- DEFINE Basement_Computer HOUSE A UNIT 7
-
- Now when a message is broadcast by the CP290, a scan of all the
- definitions will be made to see if the HOUSE and UNIT codes match. If
- so, then the description will be used instead of the codes. Therefore,
- you would get the following message on your screen.
-
- Sun Mar 24 07:00:13 1991 (A6) Plant_Grow_Lights ON
- Sun Mar 24 08:43:13 1991 (A1) Porch/Garage_Lights ON
-
- In the above messages, a combined House and Unit code (A6) is
- automatically provided - you don't have to include it as part of the
- DEFINE token.
-
- Also, the DEFINE must include BOTH the HOUSE and UNIT tokens when
- describing an object. You can not use the short cut method, such as:
-
- DEFINE Porch/Garage_Lights A 1 <=== will NOT work.
- DEFINE Porch/Garage_Lights HOUSE A UNIT 1 <=== will work.
-
- If different modules are controlled by a single event, the module
- which has the lowest UNIT code will be displayed. Therefore, if
- modules C9 and C10 are programmed as a single event, only C9 will be
- displayed.
-
- XA Command Interpreter (Version 1.04) Page 23
- Monitoring is useful when running on a multitasking system. It has
- been tested as a background task under Windows 3.0 (386 enhanced
- mode). It should work for Desqview as well.
-
-
- You can also log these events to a file called XA.LOG by specifying
- either the LOG token in a command file or the [+l] option on the
- command line. Each event reported by the CP290 will be displayed on
- the screen, and also be appended to the file XA.LOG. By appending the
- information, all previous events will be saved.
-
- For logging to work, you must have invoked the monitoring feature by
- specifying either MONITOR in the command file or [+m] on the command
- line.
-
-
-
-
- 7) POWERUP Utility
-
- The POWERUP utility is provided in this package to help you perform
- unattended, and automatic event downloads to the interface if your
- computer is controlled by an Appliance module. POWERUP should be
- placed in your AUTOEXEC.BAT file so it will always be executed after
- your computer boots. This way, it can decide whether or not it's time
- to perform any updates to your interface, and it prevents you from
- needlessly sending commands when you don't need to.
-
- The POWERUP command has the following form:
-
- POWERUP d=day [[d=day]...] s=hh:mm e=hh:mm
-
- The command line parameters may appear in order, and they must all be
- present:
- d=day - This is the text string for the day you want to
- check for. Legal strings are: MONDAY, TUESDAY,
- WEDNESDAY, THURSDAY, FRIDAY, SATURDAY, SUNDAY,
- WEEKDAYS, WEEKENDS, and EVERYDAY.
-
- s=hh:mm - This is the "window" start time. Hours must be
- entered in 24 hour format only.
-
- e=hh:mm - This is the "window" end time. Again, 24 hour
- format is required.
-
- Example: POWERUP d=SUNDAY s=2:55 e=3:05
-
- If the "day" specified matches the day reported by DOS, and the time
- reported by DOS falls within the specified "window", then POWERUP will
- return an ERRORLEVEL of 1, otherwise a 0 is returned. Therefore, by
- placing the proper batch file commands in AUTOEXEC.BAT, you can now
- execute a variety of functions at certain times.
-
- You may enter multiple 'd=day' parameters. For instance, to have
- Powerup check for a window begining at NOON and lasting until 1:00pm
- every MONDAY, WEDNESDAY, and FRIDAY, you would enter:
-
- XA Command Interpreter (Version 1.04) Page 24
-
- POWERUP d=MONDAY d=WEDNESDAY d=FRIDAY s=12:00 e=13:00
- if errorlevel == 1 echo It's time!
-
- If your computer is controlled by an Appliance module, you can now
- automatically download revised event times. In addition, you can even
- perform other actvities such as backups, communications, etc. without
- being at your computer. I perform my backups and event revisons on
- Sunday mornings at 3:00 AM. This way, I never forget about backing up
- and now I don't have to sit around and wait for the process to finish.
- See the sample AUTOEXEC.BAT file included in this package that I use
- to accomplish this task.
-
-
- 8) License Agreement and Registration
-
- You may make copies of this program, manual, and other files and give
- it to your friends, upload it to bulletin boards, or include it in the
- library of a non-profit computer club.
-
- I expressly forbid any for-profit venture from selling this software
- and documentation, either separately or as part of a "library"
- diskette, unless written permission is granted.
-
- I disclaim any liability for its use, misuse, or abuse, including any
- direct or indirect actions. The user accepts full responsibility for
- his or her use of this program.
-
- SUPPORT SHAREWARE!
- If you find this software has any value for you, please send a
- contribution. Contributions of $20 or more will entitle you to (2)
- updates of this program as new enhnacements are added.
-
- Please share this software with others.
-
- Your suggestions are always welcome. Send any comments to the address
- given below, or you may contact me on Prodigy, or America Online.
-
- Bruce Christensen
- 6594 Hudson Ave.
- Mentor, OH. 44060-4545
-
- Prodigy ID: MHNC39A
- America Online: AuggieBen
-
- This software will be uploaded to the PC-OHIO BBS as new updates
- become available. Their number is: (216) 381-3320.
-
-
-
- X-10 is a registered trademark of X-10 (USA) Inc.
- Desqview is a trademark of Quarterdeck Office Systems.
- Windows is a trademark of Microsoft Corporation.
- Prodigy is a registered service mark and trademark of Prodigy Services Co.