- I***Ungermann-Bass NDIS Ethernet MAC Driver, version %5.%6
- I***%1 initialization started.
- I***%1 initialization succeeded.
- E***%1 initialization failed.
- E***The driver's call to the GetDOSVar DevHlp system call failed.
- E***No Protocol Manager driver (PROTMAN$) is installed.
- E***There is no PROTOCOL.INI information at all.
- E***There is no section in PROTOCOL.INI with DriverName equal to %1$, or to %1n$, n = 2, ..., 9.
- E***There is no section in PROTOCOL.INI with DriverName equal to %1$.
- E***%2 is already installed.
- E***The %5 %1 drivers called for by PROTOCOL.INI are already installed.
- E***The parameter keyword "%4" in the [%3] section of PROTOCOL.INI is misspelled, or not supported by %1.
- E***Too many parameter values are specified for "%4" in the [%3] section of PROTOCOL.INI.
- E***The type of value given for "%4" in the [%3] section of PROTOCOL.INI is wrong.
- E***The value given for "%4" in the [%3] section of PROTOCOL.INI is too large for %1.
- E***The value given for "%4" in the [%3] section of PROTOCOL.INI is too small for %1.
- E***A bad parameter value is given for "%4" in the [%3] section of PROTOCOL.INI.
- E***The value specified for "%4" in the [%3] section of PROTOCOL.INI is too long.
- E***GDT selector allocation failed.
- E***Conversion of the adapter's memory window address to a GDT virtual address failed.
- E***Conversion of the NIU memory window address to a virtual address failed.
- E***Slot %5 does not contain an NIUps adapter.
- E***The NIUps in slot %5 is not enabled.
- E***Either there are no enabled NIUps adapters, or they are all reserved by other %1 drivers.
- E***The NIUps is configured for an illegal window size.
- E***The NIU failed its diagnostic tests. Please check the network connection, configuration parameters, and hardware installation.
- E***The adapter was reset successfully, but it did not respond after that.
- E***The adapter passed its diagnostic tests but failed to halt.
- E***The adapter passed its diagnostic tests and was halted, loaded, and started, but it did not complete its initialization.
- E***The adapter passed diagnostics and seemed to initialize properly, but its adapter-to-PC interrupt does not work.
- E***Working storage GDT selector allocation failed.
- E***The memory needed for working storage could not be allocated.
- E***Setup of the GDT selectors for working storage failed.
- E***The configured number of receive buffers is too large.
- E***The memory needed for receive buffers could not be allocated.
- E***Receive buffer GDT selector allocation failed.
- E***Setup of the GDT selector for ReceiveChain descriptors failed.
- E***Setup of the GDT selectors for ReceiveChain buffers failed.
- E***The %3 module was unable to register with the Protocol Manager.
- E***Interrupt handler installation failed.
- E***Memory window: 0x%5-0x%6. IO Ports: 0x%7-0x%8. IRQ level: %9.
- E***Max transmits: %5. Max multicasts: %6.
- E***Receive method: %5.
- E***Receive buffers: %5. Receive buffer size: %6.
- E***Permanent address: %5.
- E***Memory used: %5 bytes, in conventional memory.
- E***Memory used: %5 bytes, in upper memory.
- E***Memory used: %5 bytes in low memory; %6 bytes in high memory.
- E***Memory used: %5 bytes, all in low memory.
- E***Permanent address: %5. Slot number: %6.
-