- TEST UPDATE INFORMATION
- -----------------------
-
-
- 02/03/94 16:55 PCBOARD.EXE
- --------------------------
- - Disabled the use of "A", for (A)rcView, at the flagging "more?" prompt. This
- was long ago replaced with (V)iew, but the "A" has been kept as a synonym for
- a number of years.
-
- - Modified the (P)rotocol selection, just before the file transfer begins, so
- that it will not allow you to select ASCII if you have specified a known
- "binary" type of file to be transferred.
-
- - Made a fix in the way alias names are handled in the message base when
- selecting messages to read.
-
- - Modified the SELECT command to allow CTRL-X to abort out during the
- selection process.
-
-
- 02/03/94 16:14 PCBSETUP.EXE
- ---------------------------
- - Added the forward slash (/) as a valid character in conference names.
-
-
- 01/31/94 17:57 PCBOARD.EXE
- --------------------------
- - Found that the ARNET OS/2 Device Driver required a short delay in between
- opening the comm port and testing to see if Carrier Detect (CD) was up.
- Without the delay, the driver reporting it as being down which affected
- returning from a door. Fixed by inserting a delay after opening the port.
-
- - Modified the %ENV% environment variable support (in display files) so that
- more than one variable can be included in the path. In other words, the
- following is now valid: %DRIVE%%DIR%file.txt
-
- - If you used "CHAT G" from an "End of Message Command" prompt, upon return
- PCBoard could go into a non-stop display of messages. Fixed.
-
- - Made a change to increase the "abortability" of file scans. If no files
- were being found you had to have your timing just about right on hitting a
- ctrl-x when the directory description was being displayed in order to abort.
- Now it should abort with less effort.
-
- - Modified upload processing so that, after running pcbtest.bat, if the UPDESC
- file does not exist, PCBoard won't complain about its non-existence.
-
- - Modified /CID processing to convert underscores to spaces.
-
- PPL
- ---
- - Minor modification to the MOUSEREG statement in PPL for better RIP
- compatibility.
-
-
- 01/31/94 16:01 PCBFILER.EXE
- ---------------------------
- - If, after saving a DIR file, you answered "Y" to this question:
-
- Check for duplicate files in each text DIR listing processed?
-
- Then during the processing of the DIR files, PCBFiler could lose or mess up
- the secondary description lines. Fixed.
-
-
-