Event Message:

The fault tolerance driver was unable to map a faulty sector from use by the system on filename.

Source Event Log Event ID Event Type
ftdisk System 5 Warning

Explanation:

The specified name is a fault tolerance set member name; it refers to a fault tolerance partition. There is a bad sector on one of the disks on one side of the mirror set. Your data security is at some risk. There is still a good sector on the other side of the mirror set, and the probability that the same sector number will go bad on both sides of the mirror is quite low.

User Action:

To regain complete data security, do the following: (1) examine the event logs to identify which drive has the bad sector; (2) back up all data on that drive; (3) reformat the drive, using the verify switch to map out the bad sector; and (4) restore the backed up data.